background image

11

888-778-9010

www.whiteselectronics.com

One  9V  battery  is  included  with  the  Matrix  100.  Use  a  9V-alkaline,  

9V-lithium-manganese dioxide, or externally charged 9V-battery. If the battery 

is fresh or recently recharged (more than 7V), the LED next to the ON/OFF 

button will produce a green light. If the battery is discharged (less than 7V) 

the LED will flash a yellow light and it is recommended that you replace the 

battery.

Battery Life

 

Based upon measurements, battery life for a 600 mA-hour alkaline battery at  

 

room temperature is:

Battery life is doubled with the 1200 mA-hour lithium-manganese dioxide

 

batteries

.

 

Rechargeable  9V  batteries  can  also  be  used,  but  battery  life  per  charge 

is  typically  much  shorter  than  the  life  of  9V-alkaline  batteries,  and 

depends  upon  the  battery  type  and  the  battery  recharging  system. 

 

WARNING

DO NOT use the earbud jack as a recharging port! 
Use of the earbud jack as a recharging port may 
damage  the  Matrix  100  or  the  battery  charger, 
and will void the warranty.

Battery Temperature Ratings

 

Alkaline batteries are rated by the following manufacturer:

 

 

Energizer  -18°C to 55°C (0°F to 130°F)

 

 

Panasonic  -20°C to 54°C (-4°F to 130°F)

 

Lithium-manganese dioxide batteries are rated by the following  

 

 

 

manufacturer:

 

 

Duracell  -20°C to 60°C (-4°F to 140°F)

 

 

Energizer  -40°C to 60°C (-40°F to 140°F)

 

 

Ultralife  -20°C to 60°C (-4°F to 140°F)

Manufacturer’s ratings are based upon operating loads quite different from  

the Matrix 100, so it is possible to have different results.

* For information about special batteries that will operate at 

temperatures as low as -40°C contact White’s Electronics, Inc.

Batteries

Hours

Days

ON

216

9

OFF

2880

120

Содержание Conquistador 100

Страница 1: ......

Страница 2: ......

Страница 3: ...attractive The Matrix 100 Handheld Metal Detector is designed to detect metal and is primarily for security applications however it is useful for a myriad of detection applications Table of Contents...

Страница 4: ...8 778 9010 www whiteselectronics com Features Front View Features Back view ON OFF button Battery door De sense button Visual indicator LED Audio speaker ON OFF LED and Low battery indicator Lanyard h...

Страница 5: ...0 www whiteselectronics com Features Back View Battery door De sense button Visual indicator LED Scan area Sensitivity control access hole Volume control access hole Earbud jack with rubber plug Lanya...

Страница 6: ...lectronics com Features Top Edge Features Bottom Edge Mechanical Drawing metric Dimensions De sense button Scan area Visual indicator LED Battery door Lanyard hole Scan area Battery door Earbud jack a...

Страница 7: ...7 888 778 9010 www whiteselectronics com Features Battery Door Battery door Stylus Battery polarization graphic...

Страница 8: ...ouble ash for medium sensitivity or a triple ash for high sensitivity ON Vibrate press the ON OFF button twice This will be followed by a single vibration burst and the ON indicator LED will emit a si...

Страница 9: ...o press the sensitivity control to cycle through the sensitivity levels low medium or high The unit will beep or vibrate and will ash the red visual indicator LED to announce the new sensitivity level...

Страница 10: ...s turned off or the battery is removed the ear bud volume level setting is retained in the memory Testing the Scanner Turn on the scanner in the ON Audio or ON Vibrate mode Pass the scanner over a met...

Страница 11: ...fe of 9V alkaline batteries and depends upon the battery type and the battery recharging system WARNING DO NOT use the earbud jack as a recharging port Use of the earbud jack as a recharging port may...

Страница 12: ...12 888 778 9010 www whiteselectronics com Battery Installation Gently slide the battery door open Slide a 9V battery into the battery cavity as shown below Close the battery door L...

Страница 13: ...ity by approximately 50 This is particularly useful when scanning near rebar reinforced oors The De sense is only activated as long as the button is depressed While the De sense button is pressed the...

Страница 14: ...whiteselectronics com Earbud jack The earbud jack accepts a 3mm or 1 8 Mono connector Earbud Jack Rubber Plug The rubber plug helps protect the earbud jack against dirt and moisture Earbud jack Earbu...

Страница 15: ...handheld detectors in schools While it is not dif cult to learn to use a handheld metal detector correctly school administrators should not underestimate the value of annual training for their operato...

Страница 16: ...the torso down the leg to the ankle then move to the other ankle and sweep back up the front of this opposite leg and torso ending with the opposite shoulder If a particular detector s detection padd...

Страница 17: ...m causing item Continue the scan even though you nd one or more items in the process The lower abdominal area is particularly dif cult to scan because this area is private in nature and because of the...

Страница 18: ...S Schools National Institute of Justice U S Department of Justice Washington DC September 1999 Available online at http www ojp usdoj gov nij pubs sum 178265 htm There have been no conclusive studies...

Страница 19: ...ems not covered by this warranty are as follows Batteries Failures caused by abuse Tampering with the internal electronics Battery leakage Repairs made by an unauthorized party Contaminants Use in adv...

Страница 20: ...at 50 cm 19 68 43 cm 33 cm 21 cm Scan area is cylindrical 28 cm long Diameter is 2x the sensitivity distance for the object class plus 2 cm 79 Scan speed All object size classes 0 1 to 2 0 m s 04 to 7...

Страница 21: ...r Service Representatives at 888 778 9010 Maintenance Perform daily inspection to ensure the Matrix 100 is operating properly Inspect the battery to ensure it is fresh or charged and that the Matrix 1...