Whitehall SP-1600-A Скачать руководство пользователя страница 8

WHITEHALL MANUFACTURING

 • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A

Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com

6

Instructions for Operation and Care of Water Bath SP-1600-A

NOTE:  If  the  appliance  is  operated  without  water,  the 
concealed heating element may be subjected to damage 
and  may  no  longer  heat  up  the  tank  reservoir  even 
though  power  is  "ON".  If  heating  element  becomes 
damaged, it will have to be replaced.

--------------------------------------

Mains  circuit  breaker  may  have  "tripped".  Reset  the 
Power Mains circuit breaker. Plug in the Water Bath to a 
G.F.C.I.  protected  electrical  receptacle.  Do  not  plug  in 
any other devices or appliances to the same receptacle 
the Water Bath is using.

The  Water  Bath  is  provided  with  an  Over-Temp 
thermostat.  If  the  operating  thermostat  fails  the 
temperature  will  rise.  When  a  temperature  of  215°F 
(102°C)  is  achieved  the  over-temp  thermostat  will  open 
the circuit and the temperature will drop to 180°F (82°C), 
then  rise  again.  This  cycle  will  continue  until  the 
operating thermostat is replaced.

The  appliance  will  require  a  qualified  technician  to  turn 
over  the  unit;  carefully  remove  the  bottom  cover  by 
removing  the  mounting  screws.  The  technician  will 
troubleshoot and/or replace the operating thermostat. 

I filled my Water Bath with water, plugged it in, turned 
it  "ON"  (power  switch  is  not  illuminated),  the 
temperature  display  is  not  illuminated,  and  the  unit  is 
not heating up the water.

The  heating  element  should  be  visually  and  electrically 
inspected to ensure that it is still in good, proper working 
condition.  Make  sure  the  heating  element  did  not 
delaminate  from  the  underside  of  the  tank.  Make  sure 
the  heating  element  still  has  electrical  continuity  by 
checking  circuit  with  a  Multi-Meter.  Check  that  the 
heating  element  does  not  have  dark  discolored  spots, 
which may indicate that the element has burned.

Electrical  component(s)  such  as  power  inlet,  fuse 
holders,  fuse  carriers,  power  switch,  quick  disconnect 
terminals,  wire  connectors,  wiring,  etc.  may  have 
become  faulty.  A  qualified  electrical  technician  should 
perform  an  electrical  continuity  inspection  of  the  entire 
electrical system using a Multi-Meter to identify possibly 
bad  electrical  component(s).  Replace  electrical 
component(s) as required.

--------------------------------------

My Water Bath temperature raises and lowers by itself?

Equipment  Circuit  Protection  fuse(s)  may  have  "blown". 
Check fuse(s) for electrical continuity using a Multi-Meter 
(Comb.  Volt, Ampere,  &  Ohm  meter).  Replace  fuse(s)  if 
necessary.  Be  sure  to  use  the  correct  fuse  size  &  type. 
Refer to the Repair Parts section of the manual.

This will allow the lid to open past 90º and keep the lid in 
an upright position. Please keep these parts as they can 
be used to reassemble the lid stays to the lid if a partially 
open lid is again warranted.

Before  reassembling,  be  sure  to  perform  a  visual  and 
electrical inspection on the rest of the electrical system. 
Make certain all other electrical components are in good, 
working condition. Replace any components that appear 
to be burned or have become faulty.

--------------------------------------

How do I know what to adjust the temperature to?

--------------------------------------

How do I open the lid more than 90

º

?

How long will it take for my Water Bath to reach the 
adjusted temperature?

Remove  the  hinge  stays  from  the  pins  located  in  the 
tank. Make sure to reinsert the screws. 

How do I adjust the temperature on the Water Bath?

Follow  the  detailed  instructions  in  the  SET-UP 
INSTRUCTIONS,  "Item  #8  -  Changing  the  temperature 
on  your  Water  Bath".  This  will  explain  in  detail  how  to 
adjust the temperature.

 

Refer  to  splint  material  manufacturer  for  recommended 
temperature & duration of splint material used.

--------------------------------------

Allow  60  to  75  minutes  for  the  appliance  to  reach   
temperature. Keep Lid closed to ensure quickest heat-up 
and to maintain set point temperature.

 

--------------------------------------

Make  sure  unit  is  unplugged  and  all  water  is  drained 
from  the  tank.  Take  an  adjustable  wrench  and 
screwdriver and remove the 2 screws and nuts from the 
lid stay on the underside of the lid. Remove the lid stay 
and  reinstall  the  screws  and  nuts  in  the  lid.  Follow  this 
procedure for both sides. 

FAQs

 

(Frequently Asked Questions)

 

& TROUBLESHOOTING

Содержание SP-1600-A

Страница 1: ...BATH INSTRUCTIONS FOR OPERATION AND CARE OF 800 782 7706 626 968 6681 www whitehallmfg com P O Box 3527 City of Industry CA 91744 0527 U S A Division of Acorn Engineering Company 6900 117 000_REV_B Revised May 31 2019 ...

Страница 2: ...personal injury or damage to the equipment is possible WARNING To avoid electric shock connect the instrument to properly earth grounded GFCI protected 3 prong receptacles only Failure to observe this precaution can result in severe injury Ÿ ALWAYS allow the appliance to cool down before draining water or moving unit Ÿ DO NOTuse the lid handle to lift or transport appliance Ÿ NEVER leave appliance...

Страница 3: ...3 Preparing to fill your Water Bath 4 Filling your Water Bath 4 Preparing to turn ON your Water Bath 4 Turning ON your Water Bath 4 Changing the temperature on your Water Bath 4 Using Your Water Bath 5 Table of Contents Emptying Your Water Bath 5 Care Cleaning of Your Water Bath 5 Product Specifications Model SP 1600 A 2 Table of Contents 1 FAQ Troubleshooting 6 7 Troubleshooting for Temperature C...

Страница 4: ...ial heat up temperature duration is based on the splint material manufacturer s requirements and instructions The Water Bath is primarily constructed of Type 304 Stainless Steel material is internally insulated and has variable temperature settings with a LED display and a concealed wire wound heating element The Water Bath is a water tank capable of heating water within a set temperature range of...

Страница 5: ...mmediately This Whitehall product has been carefully packaged at the factory to minimize the possibility of damage during shipping Inspect the packaging for external signs of damage WARNING Do not attempt to operate this equipment if there is evidence of shipping damage or you suspect the unit is damaged Damaged equipment may present additional hazards to you Contact Whitehall technical support fo...

Страница 6: ...pped to lower temperature Your water temperature is adjustable and can be set to reach splint materials recommended operating temperature See splint manufacturer s instructions Note Most splint material on the market today has an operating range between 113 F 45 C to 200 F 93 C Your Water Bath is capable of approximate maximum temperature of 200 F 93 C depending on amount of water in unit The ther...

Страница 7: ... the open position and will not close place index finger on the left side lid stay reset button and work lid up and down until lid stays synchronize and allow lid to close USING YOUR WATER BATH EMPTYING YOUR WATER BATH The appliance should be routinely cleaned to help ensure the appearance as well as years of reliable service Routine cleaning helps to remove contaminants from the stainless steel s...

Страница 8: ...ck disconnect terminals wire connectors wiring etc may have become faulty A qualified electrical technician should perform an electrical continuity inspection of the entire electrical system using a Multi Meter to identify possibly bad electrical component s Replace electrical component s as required My Water Bath temperature raises and lowers by itself Equipment Circuit Protection fuse s may have...

Страница 9: ...t Replace the thermostat The thermostat is set too high The thermostat is broken Splint material too hot The ON OFF switch is broken Replace the switch Turn on the circuit breaker Replace the thermostat Replace the heating element Circuit breaker is off Thermostat is not working Heating element is burned out is ON plugged in and switch even though unit is Water doesn t get hot Splint material too ...

Страница 10: ... in the above figure identifies the location of the bonding terminal which is bonded to conductive accessible parts of the enclosure for safety purposes Protective Conductor Terminal Alternating Voltage or Current Fuse Location Symbols on labels Use only Time Delay Fuse See Parts List Page 10 Item 26 FUSE 1 FUSE 2 WHT BLK YEL GRN WHT BLK DPST SWITCH HEATING ELEMENT OVER TEMP SENSOR OPERATING THERM...

Страница 11: ... CA 91744 0527 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com 9 Instructions for Operation and Care of Water Bath SP 1600 A 15 5 3 6 7 8 1 4 21 17 13 12 10 14 16 9 18 22 28 27 29 11 2 30 19 18 24 23 26 25 Fuse 1 Fuse 2 20 ...

Страница 12: ...er Control Knob 9 6903 152 000 1 4 NPT SST Ball Valve 10 6903 160 000 1 4 NPT x 1 4 Tube Drain Barb SST 11 5903 715 199 Bottom Cover Assembly 12 7000 415 000 Self Retaining J Nut 13 6502 100 000 8 32 x 3 8 Phil Pan Head Screw 14 6900 138 000 Pull Handle 4 5903 741 001 Side Hinge Bracket L Assembly 15 6900 154 000 10 24 x 1 2 Pan Head Screw SST 23 6903 150 000 Operating Thermostat 24 6903 556 000 H...

Страница 13: ... A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com 11 Instructions for Operation and Care of Water Bath SP 1600 A Switch Heating Element Thermostat Digital Thermometer Power Inlet Fuse Holder Fuse Operating Thermostat ELECTRICAL PARTS DISASSEMBLY ...

Страница 14: ...h have been damaged by other causes such as mishandling or improper care or abnormal use The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Whitehall under this warranty Whitehall shall not be liable under any circumstances for incidental consequential or direct charges caused by defects in the materials or any delay in the rep...

Отзывы: