Whitehall E-27-S Скачать руководство пользователя страница 10

WARNING

Turbine assembly is provided with a 3-way plug. The 
third prong functions as a built-in ground and must be 
plugged into a matching grounded receptacle to 
properly ground the product. 

WARNING

COMPLETELY LUBRICATE THE PLUNGER ASSEMBLY.

E-

CLOCKWISE, THEN FULLY COUNTERCLOCKWISE TO 

HANDLE  5 . INTERNAL BUSHING MAY NEED ADJUSTMENT.

B-

A-

LEVEL OF AGITATION AND PRESSURE.

E-

UNTIL THE PUMP  12  IS AT THE DESIRED LOCATION.  TIGHTEN

PUSHING DOWN ON TOP OF THE MOTOR SUPPORT CASTING  14

D-

C-

CLOCKWISE, THIS PROVIDES MAX PRESSURE AND AGITATION.

B-

WATER LEVEL SHOULD BE A MAXIMUM OF 4" BELOW THE RIM

A-

INTO LOWER BRACKET  9 , TIGHTEN SCREW  10 .

D-

ASSEMBLY  4  AND TIGHTENING HANDLE  5 .

MOTOR SUPPORT ROD  6  INTO RAISING AND LOWERING 

LOWERING ASSEMBLY  4  BY LOOSENING HANDLE  5 , SLIDING

C-

A-

(SEE DETAIL A) NOTE: FOR INFORMATION ON OPTIONAL
THERMOSTATIC MIXING VALVE CONTACT FACTORY.

B-

TURN THE PRESSURE CONTROL VALVE HANDLE  11  FULLY

LIFT COMBINATION DRAIN & OVERFLOW ASSEMBLY HANDLE  15 .

TURN OFF SWITCH  13 .

ADJUST PRESSURE CONTROL VALVE  11  TO DELIVER DESIRED

ADJUST RAISING AND LOWERING ASSEMBLY  4  BY SLOWLY

TURN ON THE SWITCH  13 .

TURN THE PRESSURE CONTROL VALVE HANDLE  11  FULLY

FILL TUB AS DESIRED USING THERMOSTATIC MIXING VALVE.

INSTALL THERMOMETER  7  THRU UPPER BRACKET  8  AND 

INSTALL MOTOR/TURBINE ASSEMBLY  3  INTO RAISING AND

ROUGH-IN FOR 2" OD DRAIN LINE  1  AND WATER INLET VALVE.

LOCATE TANK AND SECURE WITH "L" BRACKETS  2 , WITH 

F-

REFERENCE DRAWINGS

ASSEMBLIES

RAISING/LOWERING

MOTOR/TURBINE

9

17

PAGE NUMBER

27

DRAIN OVERFLOW

PROVIDE ELECTRICAL SERVICE AND PROPERLY INSTALLED,
GROUND FAULT CIRCUIT INTERRUPTER (GFCI) FOR MOTOR
SPECIFIED. MOTOR SPECIFICATIONS AVAILABLE ARE EITHER
120V AC / 60 HZ ON 15A CIRCUIT OR 240 V AC / 50 HZ ON 10A

AND A MINIMUM OF 6" ABOVE BOTTOM PUMP  12 .

ASSEMBLY PROCEDURE:

OPERATION PROCEDURE:

DRAINING PROCEDURE:

INSTALLER PROVIDED FLOOR ANCHORS AND ANCHORING
HARDWARE. MAKE WASTE CONNECTIONS  1 .

22

THERMOMETER

6

7
8

"

17"

TYP.

1

1
4

"

TYP.

12

1

8

"

13

11

12

6

14

3

15

5

4

1

2

7

8

10

9

DETAIL "A"
(TOP VIEW)

Installation Instructions; Slant Back

8

Содержание E-27-S

Страница 1: ...E 27 S S 90 S 6900 194 000 INSTRUCTIONS FOR OPERATION AND CARE OF Stationary Whirlpool Member of Revised February 2016...

Страница 2: ...ed tested and certified as complying with all applicable European Union regulations and recommendations Waste Electrical and Electronic Equipment WEEE This symbol on the product or on its packaging in...

Страница 3: ...age 12 Stationary P Series Page 13 Stationary S Series Page 14 Motor Raising Lowering Assembly Small Page 15 Motor Raising Lowering Assembly Page 16 Motor Raising Lowering Assembly Slant Back Page 17...

Страница 4: ...ol free of excessive wear Does the turbine mount securely in place Is a properly grounded and voltage matched hospital grade receptacle available for the turbine Is the outlet or turbine cord equipped...

Страница 5: ...safe practices for the patient and themselves If a turbine is used Plug the turbine cord only into a receptacle that is voltage matched properly grounded and polarized Verify that the receptacle has G...

Страница 6: ...RECEPTACLE HOSPITAL ELECTRICAL REQUIREMENTS 8 AMPS 115 VOLTS GRADE WITH GROUND FAULT INTERRUPT FOR TURBINE 12 305 REC MIN 12 305 REC MIN B 521 4 1327 521 4 1327 B 43 4 120 A 1 ASSEMBLY 2 3 4 5 6 7 8...

Страница 7: ...2 or 3 4 IPS H 75 S 42 1067 20 508 28 711 34 864 33 838 29 737 1 2 or 3 4 IPS H 90 S 48 1219 20 508 28 711 34 864 36 914 29 737 1 2 or 3 4 IPS H 105 S 48 1219 24 610 28 711 34 864 26 660 31 787 1 2 o...

Страница 8: ...OL VALVE HANDLE 11 FULLY LIFT COMBINATION DRAIN OVERFLOW ASSEMBLY HANDLE 15 TURN OFF SWITCH 13 ADJUST PRESSURE CONTROL VALVE 11 TO DELIVER DESIRED ADJUST RAISING AND LOWERING ASSEMBLY 4 BY SLOWLY TURN...

Страница 9: ...TURN THE PRESSURE CONTROL VALVE HANDLE 11 FULLY TURN HANDLE 15 CLOCKWISE TO OPEN DRAIN VALVE 16 TURN OFF SWITCH 13 ADJUST PRESSURE CONTROL VALVE 11 TO DELIVER DESIRED ADJUST RAISING AND LOWERING ASSE...

Страница 10: ...COMBINATION DRAIN OVERFLOW ASSEMBLY HANDLE 15 TURN OFF SWITCH 13 ADJUST PRESSURE CONTROL VALVE 11 TO DELIVER DESIRED ADJUST RAISING AND LOWERING ASSEMBLY 4 BY SLOWLY TURN ON THE SWITCH 13 TURN THE PRE...

Страница 11: ...1 4 20 x 5 8 PHIL PAN HEAD SCREW 7 6502 300 000 8 32 x 3 8 PHIL FLAT HEAD SELF TAPPING 8 6525 514 199 SHAFT BEARING 9 6502 410 000 1 4 20 x 1 4 DOG SET SCREW 10 6502 352 000 3 8 16 x 3 HEX CAP SCREW 1...

Страница 12: ...ASSY E 45 115VAC 60Hz 1L 6525 166 001 TURBINE ASSY E 45 230VAC 60Hz 1M 6525 167 001 TURBINE ASSY E 45 230VAC 50Hz 2A 6525 525 001 PLUNGER ASSY 12 E 15 S 2B 6525 528 001 PLUNGER ASSY 15 1 4 E 22 S 2C...

Страница 13: ...H 105 M SDP DD 4828 DD 3628 1A 6525 168 001 TURBINE ASSY H 60 75 90 105 115VAC 60Hz 1B 6525 169 001 TURBINE ASSY H 60 75 90 105 230VAC 60Hz 1C 6525 170 001 TURBINE ASSY H 60 75 90 105 230VAC 50Hz 2 6...

Страница 14: ...L 90 M SDP L 105 M SDP DD 6018 DD 6618 1A 6525 158 001 TURBINE ASSY L 75 90 105 115VAC 60Hz 1B 6525 159 001 TURBINE ASSY L 75 90 105 230VAC 60Hz 1C 6525 160 001 TURBINE ASSY L 75 90 105 230VAC 50Hz 2...

Страница 15: ...230VAC 50Hz 1G 6528 108 001 TURBINE ASSY P 22 115VAC 60Hz 1H 6528 109 001 TURBINE ASSY P 22 230VAC 60Hz 1J 6528 110 001 TURBINE ASSY P 22 230VAC 50Hz 2A 6528 522 001 PLUNGER ASSY 9 1 2 P 10 2B 6528 5...

Страница 16: ...DP S 90 M SDP S 110 M SDP 1A 6525 165 001 TURBINE ASSY S 85 90 110 115VAC 60Hz 1B 6525 166 001 TURBINE ASSY S 85 90 110 230VAC 60Hz 1C 6525 167 001 TURBINE ASSY S 85 90 110 230VAC 50Hz 2 6525 535 001...

Страница 17: ...509 205 199 1 1 8 DIA x 12 1 8 TUBE P 10 S 2B 6509 215 199 1 1 8 DIA x 18 TUBE P E 15 S 2C 6509 215 199 1 1 8 DIA x 18 TUBE P E 22 MU SP 2D 6509 225 199 1 1 8 DIA x 20 TUBE P E 22 S 3A 6503 005 000 7...

Страница 18: ...L 75 90 105 S 1E 6530 210 001 1 DIA R L ASSY L 75 90 105 M SL 1F 6530 225 001 1 DIA R L ASSY E 45 SL S 85 90 110 M SL 2A 6509 265 199 1 3 8 DIA x 23 1 2 TUBE E 27 S 2B 6509 275 199 1 3 8 DIA x 27 1 4...

Страница 19: ...99 LOCKING HUB 4 6530 114 199 3 8 16 UNC STUD 5 6530 112 199 BUSHING 6 6530 111 199 LOCKING HANDLE 7 0116 104 000 1 4 20 x 1 2 PHILLIPS ROUND HEAD SCREW 8 6530 310 199 END CAP 9 6530 520 000 1 4 20 ST...

Страница 20: ...GASKET 8 6508 050 199 STRAINER 9 6508 010 199 DRAIN TEE 10 6509 375 199 2 O D x 24 DRAIN TUBE SPORTS 11 6531 056 001 33 1 4 OVERFLOW ASSEMBLY HI BOY 12 6531 055 001 29 5 8 OVERFLOW ASSEMBLY 13 6531 10...

Страница 21: ...Y E 22 SP 8B 6531 054 001 26 OVERFLOW ASSEMBLY E 27 S 8C 6531 055 001 29 5 8 OVERFLOW ASSEMBLY E 45 S 9 6531 102 199 HANDLE 10 6502 450 000 8 32 x 3 8 PAN HEAD PHILLIPS SCREW 11 6531 110 001 FRICTION...

Страница 22: ...D x 17 DRAIN TUBE L 75 90 105 S 8 6531 052 001 22 1 2 OVERFLOW ASSEMBLY 9 6531 102 199 HANDLE 10 6502 450 000 8 32 x 3 8 PHILLIPS PAN HEAD SCREW 11 6531 110 001 FRICTION LOCK ASSEMBLY 12 6531 100 199...

Страница 23: ...15 S 8C 6531 052 001 22 1 2 OVERFLOW ASSEMBLY E P 22 S 9 6531 102 199 HANDLE 10 6502 450 000 8 32 x 3 8 PHILLIPS PAN HEAD SCREW 11 6531 110 001 FRICTION LOCK ASSEMBLY 12 6531 100 199 OVERFLOW BRACE 13...

Страница 24: ...111 199 FRICTION LOCK ROD 15 6531 113 000 SPRING 16 6531 112 199 TENSION ADJUSTER 17 6531 101 199 COLLAR UPSTOP OVERFLOW 7 6508 010 199 DRAIN TEE 18 WHR00047 001 23 3 8 OVERFLOW TUBE ASSEMBLY 8 6509...

Страница 25: ...2 O D ANGLED DRAIN TUBE P E 15 22 S 6 6531 325 001 DRAIN VALVE ASSEMBLY 7 6509 600 199 DRAIN ROD P 10 S P E 15 S 8 6509 601 199 DRAIN ROD P E 22 S 9 6531 330 000 STRAINER ASSY FOR SDO BURN TANKS 10 6...

Страница 26: ...IN TUBE E 45 S 6 6531 325 001 DRAIN VALVE ASSEMBLY 7A 6509 602 199 DRAIN ROD E 22 SP 7B 6509 603 199 DRAIN ROD E 27 S 7C 6509 604 199 DRAIN ROD E 45 S 8 6531 330 000 STRAINER FOR SDO BURN TANK ASSEMBL...

Страница 27: ...D DRAIN TUBE S 85 S 5E 6531 407 199 2 O D x 21 1 4 DRAIN TUBE S 90 S 6 6531 325 001 DRAIN VALVE ASSEMBLY 7 6509 605 199 DRAIN ROD H 60 75 90 S 8 6509 604 199 DRAIN ROD S 85 90 S 9 6531 330 000 STRAINE...

Страница 28: ...STAINLESS STEEL HEX HD BOLT 4 6504 506 000 DRAIN VALVE GASKET 5 6531 323 000 WAFER BUTTERFLY VALVE 6 6531 332 199 VALVE COUPLING 7 6502 402 000 5 16 18 x 1 4 HEX SOCKET SET SCREW 8 6531 320 199 DRAIN...

Страница 29: ...ETER 21 2B 6532 075 000 BOTTOM CONNECTED THERMOMETER 25 2C 6532 080 000 BOTTOM CONNECTED THERMOMETER 28 3 6502 451 000 10 32 x 1 4 PAN HD SLOTTED NYLON SCREW 4 6532 100 199 UPPER THERMOMETER BRACKET 5...

Страница 30: ...with a mixture of suitable disinfectant solution per manufacture s recommended use Exposed surfaces should remain wet for at least 10 minutes 6 Drain the turbine bucket into the tank and open drain 7...

Страница 31: ...LAZE STAINLESS STEEL Protecting the powder coated surface in keeping an Whitehall Enviro Glazed stainless steel product For normal wipe down cleaning a mild soap and a sponge or cotton cloth will perf...

Страница 32: ...te The thermometer gauges temperatures from 40 to 140 F Do not allow temperatures to exceed 140 to avoid damaging the thermometer To recalibrate Immerse the stem a minimum of 4 into the water turn on...

Страница 33: ...or Assemblies Motor Capacitor Assembly Condenser Cover Motor Base WHT BLK YEL GRN GND POWER INLET L N 6 1 2 1 MOTOR 2 1 X E BLU BRN YEL GRN GND POWER INLET L N 6 1 2 1 MOTOR 2 1 X E SWITCH SWITCH MOTO...

Страница 34: ...under this warranty Whitehall shall not be liable under any circumstances for incidental consequential or direct charges caused by defects in the materials or any delay in the repair or replacement t...

Отзывы: