FIRE HAZARD

• Do not exceed the specified voltage.
• Protect the control from direct contact with water

(dripping, spraying, rain, etc.).

• If the control has been in direct contact with water,

replace the control.

• Label all wires before disconnection when servic-

ing controls. Wiring errors can cause improper
and dangerous operation.

• Route and secure wiring away from flame.

SHOCK HAZARD

• Disconnect electric power before servicing .
• Ensure proper earth grounding of appliance.
• Ensure proper connection of line neutral and line

hot wires.

EXPLOSION HAZARD

• Shut off main gas to appliance until installation is

complete.

50A65-843

Universal Integrated Furnace Control

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.

DESCRIPTION

Operator: Save these instructions for future use!

INSTALLATION INSTRUCTIONS

The 50A65-843 is an automatic gas interrupted ignition control that employs a
microprocessor to continually monitor, analyze, and control the proper opera-
tion of the gas burner, inducer, and fan.

Signals interpreted during continual surveillance of the thermostat and flame
sensing element initiate automatic ignition of the burner, sensing of the flame,
and system shut-off during normal operation.

These controls incorporate system fault analysis for quick gas flow shut-off,
coupled with automatic ignition retry upon sensing a fault correction.

PRECAUTIONS

PART NO. 37-6270E

Replaces 37-6270D

0701

Installation should be done by a qualified heating and air
conditioning contractor or licensed electrician.

If in doubt about whether your wiring is millivolt, line, or low
voltage, have it inspected by a qualified heating and air condi-
tioning contractor or licensed electrician.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and
ordinances.

This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.

Following installation or replacement, follow manufacturer’s
recommended installation/service instructions to ensure proper
operation.

CONTENTS

Description ........................................................  1
Precautions .......................................................  1
Specifications ....................................................  2
Installation .........................................................  3

Mounting & Wiring

Operation ..........................................................  6
Mounting Hole Template .................................... 8

WARNING

Failure to comply with the following 
warnings could result in personal injury 
or property damage.

CAUTION

Do not short out terminals on gas valve or primary
control. Short or incorrect wiring may damage the
thermostat.

Содержание UNIVERSAL INTEGRATED FURANCE CONTROL 50A65-843

Страница 1: ...flame sensing element initiate automatic ignition of the burner sensing of the flame and system shut off during normal operation These controls incorporate system fault analysis for quick gas flow sh...

Страница 2: ...ponse Time 2 0 sec At 50 Hz all timing specifications should be increased by 20 Gases Approved Natural Manufactured Mixed Liquified Petroleum and LP Gas Air Mixtures are all approved for use TIMING SP...

Страница 3: ...lowappliancemanufacturer s recommended installation or service instructions to ensure proper operation The 50A65 has only one serviceable part an automotive type fuse which protects the low voltage tr...

Страница 4: ...S VALVE HIGH LIMIT N C AUX HIGH LIMIT N C PRESSURE SWITCH N O FLAME SENSOR PROBE COMPRESSOR CONTACTOR ELECTRONIC AIR CLEANER HUMIDIFIER INDUCER CIRCU LATOR BLOWER 50A65 843 24 VAC 120 VAC 24 VAC CLASS...

Страница 5: ...ent low voltage thermostat Y terminal or equivalent 2nd wire from Y terminal goes to 24 VAC HOT side of compressor contactor coil 24 VAC COMMON side of compressor contactor coil gas valve both gas sol...

Страница 6: ...delay to fan off period ends the circulator fan and electronic air cleaner are de energized If flame is not detected both valves are de energized the ignitor is turned off and the 50A65 control goes i...

Страница 7: ...TURES The 50A65 843 control continuously monitors its own operation and the operation of the system If a failure occurs the LED will indicate a failure code as shown below If the failure is internal t...

Страница 8: ...MOUNTING HOLE TEMPLATE FOR MOUNTING HOLE LOCATIONS 4 172 007 2 plcs 6 402 010 2 plcs Refer to page 3 of the installation instructions for proper installation MOUNTING HOLE TEMPLATE...

Отзывы: