THERMOSTAT DETAILS

REMOVING OLD THERMOSTAT

Before removing wires from old thermostat’s switching subbase,
label each wire with the terminal designation it was removed from.

1. Remove Old Thermostat:  A standard heat/cool thermostat

consists of three basic parts:

a. The cover, which may be either a snap-on or hinge type.

b. The base, which is removed by loosening all captive screws.

c. The switching subbase, which is removed by unscrewing

the mounting screws that hold it on the wall or adaptor plate.

2. Shut off electricity at the main fuse box until installation is

complete. Ensure that electrical power is disconnected.

3. Remove the front cover of the old thermostat. With wires still

attached, remove wall plate from the wall. If the old thermostat
has a wall mounting plate, remove the thermostat and the wall
mounting plate as an assembly.

4. Identify each wire attached to the old thermostat.

5. Disconnect the wires from the old thermostat one at a time. DO

NOT LET WIRES FALL BACK INTO THE WALL.

6. Install new thermostat using the following procedures.

To prevent electrical shock and/or equipment damage,
disconnect electrical power to the system at the main
fuse or circuit breaker until installation is complete.

CAUTION

!

Printed in U.S.A.

PART NO. 37-6429A

0230

WHITE-RODGERS
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
www.white-rodgers.com

Failure to follow and read all instructions carefully
before installing or operating this control could cause
personal injury and/or property damage.

Assemble tools required as shown below.

YOUR THERMOSTAT  REPLACES

1

2

3

WIRE CUTTER/STRIPPER

HAND OR POWER 
DRILL WITH 3/16 INCH 
DRILL BIT, IF NEEDED

FLAT BLADE SCREWDRIVER

SPIRIT LEVEL OR PLUMB BOB AND LINE OPTIONAL— 

THERMOSTAT DOES NOT NEED TO BE LEVEL TO WORK PROPERLY

Description

1F73

Heat Pump (No Aux or Emergency Heat)

Yes*

Heat Pump (with Aux or Emergency Heat)

Yes*

Standard Heat & Cooling Systems

Yes*

Two Stage Heat & Two Stage Cool

Yes*

Standard Heat Only Systems

Yes*

Millivolt Heat Only Systems – Floor or Wall Furnaces

No

Standard Central Air Conditioning

Yes*

Gas or Oil Heat

Yes*

Electric Furnace

Yes*

Hydronic (Hot Water) Zone Heat – 2 Wires

Yes*

Hydronic (Hot Water) Zone Heat – 3 Wires

No

* Requires common for 24 VAC at the thermostat

(O/B)Y2

E/W1

R

C

Y1

W2

G

GAS

ELEC

B

O

L

Figure 1. Thermostat Base

Elec – Gas

Switch

Mounting

Hole

Mounting

Hole

O/B Terminal

Switches Selection

Содержание IF73

Страница 1: ...at a time DO NOT LET WIRES FALL BACK INTO THE WALL 6 Install new thermostat using the following procedures To prevent electrical shock and or equipment damage disconnect electrical power to the system...

Страница 2: ...ch require the changeover relay to be energized in COOL If the thermostat you are replacing or the heat pump being installed with this thermostat requires a B terminal to energize the changeover relay...

Страница 3: ...y Switches 24 VAC Limit or Safety Switches COMMON COMMON Auxiliary Heating Transformer Class II Current Limited Heat Pump Transformer Class II Current Limited 24 VAC ACCESSORY RELAY N O CONTACT Polari...

Страница 4: ...s for specific sys tem wiring informtion You can configure the thermostat for use with the following heat pump system types HEAT PUMP TYPE 1 Single stage compressor system gas or electric backup This...

Страница 5: ...ate The Flame icon will display flashing to indicate that the Aux system is operating 3 Press to adjust the thermostat below room temperature The Aux heating system should stop operating To prevent co...

Страница 6: ...tes 6 Select Compressor Lockout CL OFF or ON Selecting CL ON will cause the thermostat to wait 5 minutes before turning on the compressor if the heating and cooling system loses power It will also wai...

Страница 7: ...ction to thermostat or system Verify thermostat and system wires are securely attached 3 Cooling system requires service or Same procedure as diagnostic for No Heat thermostat requires replacement con...

Страница 8: ...and the size The cycle rate for cooling is fixed and can not be narrow or wide temperature swing of the Cooling System can influence the adjusted Contact a local service person for cycle rate suggest...

Отзывы: