background image

0508082120/101203/C

Page 3

Owner’s manual

Important Safety Instructions

Important Safety Instructions

Read and save these instructions

ATTENTION

Please read instructions before installing and using the air 
cleaner. This will help you obtain the full benefit from the air 
cleaner you have selected. 

A Read the Owner’s Manual and Important Safety Instructions 

carefully. Failure to follow these instructions could cause a 
malfunction of the filter or unsatisfactory service. 

B Follow a regular service and maintenance schedule for 

efficient operation. 

To reduce the risk of electric shock, fire and injury to persons:

• Do not use the air cleaner in wet or damp locations.
• The air cleaner is not for use in cooking areas.
• Do not use the air cleaner with any solid state speed control 

device.

• Do not use the air cleaner outdoors.
• Do not use the air cleaner at ambient temperatures above 

95°F/35°C. 

Mounting/installation

Please follow the installation instructions carefully.

Disconnect power prior to installing the air cleaner.

To reduce the risk of electric shock this equipment has a 
grounding type plug that has a third (grounding) pin. This plug 
will only fit into a grounding type power outlet.
If the plug does not fit into the outlet contact qualified 
personnel to install the proper outlet. Do not alter the plug in 
any way.

Use common sense, stay vigilant and pay attention to your 
actions during installation. Do not install the air cleaner when 
tired or affected by drugs, alcohol, medicines or otherwise 
impaired.

Use only screws delivered in the installation kit. Using other 
screws may damage the air cleaner and can cause a risk of 
shock, fire or injury to persons.

Do not use excessive strength to fasten the screws of the 
mounting assembly accessories. It will damage the air cleaner 
or mounts causing the air cleaner to fall. 
Do not remove a wall mounted air cleaner once it is installed.
Take special care when cleaning a wall mounted air cleaner.
Only use the special mounting kit for recessed ceiling mounted 
air cleaners.
Do not use the frame of the recessed ceiling to carry the weight 
of the air cleaner.

Fire hazard

Never use the air cleaner in areas with flammable gasses.

Never use the air cleaner to extract and/or filter flammable, 
smoldering or burning material.

Never use the air cleaner to extract and/or filter toxic fumes or 
abrasive particles.
Do not place any objects on top of the air cleaner.
Do not use with a damaged cord or plug.

Do not pull the cord to remove the plug from the mains. Protect 
the cord against heat, oil and sharp objects. Do not run any 
appliance over the cord. To unplug, grasp the plug, not the 
cord. Do not pull or carry by cord, use cord as a handle, close 
a door on cord, or pull cord around sharp edges or corners.
Do not move the air cleaner without having it unplugged first.

WARNING

ELECTROCUTION HAZARD.

Disconnect mains before servicing. Failure to do so 
could result in serious personal injury or death. 

WARNING

Do not attempt installation of this unit unless you are familiar with 
the necessary tools, equipment, utility connections and potential 
hazards. 
Installation should be performed only by a qualified service provider. 
Failure to do so could result in reduced performance of the unit, 
serious personal injury or death.

CAUTION

CELLS MAY CONTAIN SHARP EDGES.

Use care when servicing unit or handling cells. Failure 
to do so could result in minor personal injury.

WARNING

Installation of this unit must comply with local electric codes or other 
applicable codes. 
Review and understand local codes prior to installation. 
Do not use this apparatus in a flammable or explosive atmosphere. 
Failure to do so could result in serious personal injury or death. 

!

!

!

!

Содержание ECD1500B

Страница 1: ...MCD1200W MCD1200B Electronic Air Cleaner purateur d air lectronique ECS750W ECS750B ECD1500W ECD1500B 2SD1 Electrostatic Air Cleaner 2SD2 Electric Fan OWNER S MANUAL MANUEL OP RATEUR White Rodgers is...

Страница 2: ...Cabinet Air Flow Color MCS600W MC Media Cleaner S Single Cabinet 600 Maximum Air Flow CFM W White MCS600B B Bronze MCD1200W D Double Cabinet 1200 Maximum Air Flow CFM W White MCD1200B B Bronze ECS750W...

Страница 3: ...e outside of the air cleaner 3 5 CONTROL 4 5 1 Controlling with the panel button 4 5 2 Remote Control operation 4 5 3 Automatic operation auto mode 4 6 PROGRAM SETTINGS 4 6 1 Program Setting 1 Service...

Страница 4: ...ssories It will damage the air cleaner or mounts causing the air cleaner to fall Do not remove a wall mounted air cleaner once it is installed Take special care when cleaning a wall mounted air cleane...

Страница 5: ...its Ensure that the load capacity of the mounting devices is sufficient to safely support the air cleaner The weights of the air cleaner are maximum 39 9 lbs and 65 5 lbs respectively For the single a...

Страница 6: ...lowing program settings allow you to customize the air cleaner operation for your personal preference Program Setting 1 Service Indicator Program Setting 2 Resetting the Service Indicator PROGRAM pres...

Страница 7: ...n the cell for over 60 seconds the STANDBY led flashes Power will be interrupted to the cell s for 10 minutes which may allow the cause of the problem e g hair to flow out of the collecting cell After...

Страница 8: ...ill light up meaning you have set the pollution level to EXTREME DUTY If you want to go back to one of the previous pollution levels press W Press PROGRAM to confirm setting 1 and to go to setting 2 P...

Страница 9: ...of no high voltage to 120 minutes Press V led TURBO will light up meaning you ve set the time of no high voltage to 240 minutes If you want to go back to one of the previous time setting levels press...

Страница 10: ...cabinet A moderate amount of arcing or snapping may occur when the unit is turned on This may indicate that the cell s are still damp Turn the unit off and allow it more drying time or go to Program S...

Страница 11: ...causes a short circuit STANDBY led blinks Clean the electronic filter Crackling sound from the electronic filter Electronic filter dirty or wet Clean or dry the electronic filter Missing prefilter Ins...

Страница 12: ...5 0632 Media filter 2 pcs x x x x x 42 00 27b F825 0633 Media filter 40 pcs x x x x x 800 00 28 F825 0634 Electronic cell x x x x x 84 40 29a F825 0635 Activated carbon filter 72 pcs x x x x x x x x x...

Страница 13: ...82120 101203 C Page 12 Owner s manual Parts List 34 24 1 5 3 4 15 11 10 20 19 17 21 23 26 27 PROGRAM AUTO OFF 16 13 14 25 18 12 22 28 29 24 32 30 32 1 3 1 3 2 33 Replacement ionizing wires electronic...

Страница 14: ...16 5 1 Commande par le bouton frontal 16 5 2 Commande par la t l commande 16 5 3 Commande automatique mode AUTO 16 6 MODES DE PROGRAMMATION 16 6 1 Mode de Programmation 1 Indicateur Service 16 6 2 Mod...

Страница 15: ...ndommager l purateur d air et entra ner des risques de chocs lectriques d incendie ou de blessures corporelles Lors de la fixation des accessoires de montage vitez de forcer les vis pour les serrer vo...

Страница 16: ...dessus de l purateur d air N utilisez pas l appareil lorsque le fil lectrique est endommag Ne tirez pas sur le fil pour d brancher l appareil Prot gez le fil contre la chaleur l huile et les objets a...

Страница 17: ...ilisation de deux exemplaires du m me kit Pour le montage encastr du mod le simple utilisez le kit d installation F801 0196 Pour le mod le double utilisez le kit d installation F801 0197 Aucun composa...

Страница 18: ...rontal la vitesse du ventilateur passe STANDBY Pousez le bouton frontal le ventilateur s arr te OFF En poussant le bouton frontal sans cesse la commande passe la vitesse suivante chaque seconde 5 2 Co...

Страница 19: ...normal 7 REPARATION DES PANNES Si les diodes et clignotent C est l Indicateur Service Il vous pr vient de ce qu il est temps de remplacer ou nettoyer le s filtre s Appuyant quelconque bouton les diode...

Страница 20: ...du STANDBY clignote bri vement toutes les deux secondes Programmation de l appareil OFF aucune diode ne clignote Appuyez V diode LOW clignote vous avez fix le niveau de pollution sur BASSE Appuyez V d...

Страница 21: ...sensibilit la pollution sera r gl e sur lev e Appuyez V diode TURBO est commut et la sensibilit la pollution sera r gl e sur extr me Si vous d sirez retourner sur l une des sensibilit s la pollution p...

Страница 22: ...e la capacit de nettoyage du filtre lectronique Utilisez un chiffon humide pour essuyer tous les fils d ionisation en prenant soin de ne pas les endommager C Enlevez le les filtres s lectronique s de...

Страница 23: ...z le filtre lectronique Le filtre lectronique cr pite Le filtre lectronique est encrass ou humide Nettoyer le filtre lectronique ou bien le laisser correctement s cher Le pr filtre est manquant Montez...

Страница 24: ...x x x 26b F825 0631 Pr filtre 600 pi ces x x x x x x x x x 27a F825 0632 Filtre m dia 2 pi ces x x x x x 27b F825 0633 Filtre m dia 40 pi ces x x x x x 28 F825 0634 Filtre lectronique x x x x x 29a F...

Страница 25: ...3 C Page 24 Manuel op rateur Pi ces D tach es 34 24 1 5 3 4 15 11 10 20 19 17 21 23 26 27 PROGRAM AUTO OFF 16 13 14 25 18 12 22 28 29 24 32 30 32 1 3 1 3 2 33 Remplacement des fils d ionisation du fil...

Страница 26: ...7 1 2 3 4 A B C D E F G H I J K L M N O P Q click No mm inches A 554 21 81 B 497 19 57 C 463 18 23 D 298 11 73 E 215 8 46 F 92 3 62 6 G 629 24 76 No mm inches H 570 22 44 I 510 20 08 J 470 18 50 K 978...

Страница 27: ...101203 C Controlling Indoor Comfort Worldwide Since 1937 St Louis Missouri Markham Ontario 314 577 1300 905 201 470 www white rodgers com The Emerson logo is a trademark and service mark of Emerson E...

Отзывы: