Plumbing and Setting the Water Level
NOTE: 

Use copper tubing only

 to plumb the humidifier. 

Select the nearest cold water pipe and install the saddle connector and 

needle valve (provided) by following the instructions supplied with the 

valve. 

WARNING: 

Do not use any line connected to an air conditioner.

 

Lightly clean the tubing ends with fine sandpaper before making con

-

nections. 

1.

2.

Uncoil the copper tubing and 

connect one end to the saddle 

valve.  Use  the  compression 

fittings  found  in  the  self-

piercing  saddle  valve  parts 

bag. 

Place the brass compres-

sion  nut  over  the  tubing, 

then slide the brass ferrule 

over the tubing. 
Fully insert the tubing into 

the  saddle  valve  fitting 

and  tighten  the  compres-

sion  nut.  (Do  not  over-tighten;  moderate  tightness  should  prevent 

leakage.) 
Thoroughly  flush  the  supply  tubing  after  attaching  it  to  the  saddle 

valve. This will clear the line of debris which could block water flow 

at the float valve. 

Route the tubing to the humidifier float valve, keeping the tubing away 

from sharp edges. 

Connect the remaining end of the tubing to the humidifier float valve. 
Open the saddle valve so that the water flows slowly and gently into the 

water pan. 

Prior to mounting, adjust the humidifier’s water level by following these 

instructions: 

Set the humidifier reservoir on a level surface. 
Allow the unit to fill until the float valve shuts off the incoming flow of 

water. (The water should be 2-3/8" deep, plus or minus 1/8". If it is 

not, further adjustment will be necessary.) 

.

4.

5.
6.

7.


Figure 7

—Saddle Valve and Fittings

If the water level is too high, remove enough water from the reservoir to 

allow the float valve to automatically fill and shut off the water. This will 

verify that your final adjustment is correct. 

Shut off the water supply and remove all water from the reservoir. 

Mount the humidifier according to Options A, B or C, shown on pages 

5-7. 

Check the two compression fittings—one at the saddle valve, the other at 

the float valve. Stop any leakage by tightening the fittings. 
Connect the humidifier’s overflow provision to a suitable waste drain. 

A standard garden hose or a 3/8" N.P.T. male fitting (not supplied) 

can be attached to the overflow fitting. 
Provide support at many points along the hose to prevent kinks—

particularly near any heat source. 

Turn the water to the humidifier on. The float valve should shut the water 

off when the pan is filled to 2-3/8". 
Make sure the humidifier is plugged into a powered outlet. 

Adjust  the  compensating  humidistat  according  to  instructions  provided 

with the unit. 

8.

9.
10.

11.

12.

1.

14.
15.

CAUTION: 

To prevent valve seat damage, 

never adjust the humidi-

fier’s water level without supporting the float arm. 

Make adjustments 

in small increments. 

To raise the water level, push down in the center of the float arm. 

(See Figure 8-A, below.)
To lower the water level, hold the float on the bottom of the reservoir 

with one hand and pull up on the center of the float arm with the other 

hand. (See Figure 8-B, below.)

Figure 8-A

—Raising the 

water level

Figure 8-B

—Lowering the

water level

Содержание ComfortPlus HSP2000

Страница 1: ...rammable Flushing Timer Installation Instructions Operating and Maintenance Instructions CONTRACTOR Read these instructions before install ing or servicing humidifier HOMEOWNER Save this manual for fu...

Страница 2: ...INSTRUCTIONS AND INSTALLATION OF THE ELEC TRONIC COMPENSATING HUMIDISTAT PLEASE SEE SEPARATE INSTRUCTIONS ENCLOSED IN THE HUMIDIFIER CARTON Safety Precautions Do not install a humidifier where the su...

Страница 3: ...ation configurations the mounting area must be strong enough to support the humidifier s weight when it is full of water approximately 18 lbs and to hold the humidifier in a level position for safe re...

Страница 4: ...racket provided at the selected location on the bottom of the duct Use a marker to trace around the in side of the mounting bracket Cut out the duct opening CAUTION DO NOT attach the mounting bracket...

Страница 5: ...8 deep plus or minus 1 8 If it is not further adjustment will be necessary 4 5 6 7 Figure 7 Saddle Valve and Fittings If the water level is too high remove enough water from the reservoir to allow th...

Страница 6: ...come in contact with sharp edges or hot surfaces This caution applies to step 7 as well Cut a second piece of tubing to reach from the bottom fitting on the flushing timer to the drain See Step 3 Con...

Страница 7: ...tasks follow these instructions WARNING Do not touch the humidifier when the operation indicator light is on Always unplug the unit and allow it to cool prior to service or inspection 4 5 6 7 Unplug t...

Страница 8: ...is evapo rated Heavy condensation Turn humidistat down enough on windows to eliminate condensation this may be a temporary condition caused by moisture from bath ing mopping cooking etc Humidifier Hi...

Страница 9: ...see an immersed tubular heater and two floats When your home is too dry the humidistat humidity control device installed with your system activates the humidifier heater A built in thermostat senses t...

Страница 10: ...nd more homeowners are realizing that during the winter months they live in a sick house Family members suffer from dry itchy skin parched throats and annoying coughs Furniture creaks floors moan the...

Страница 11: ...ComfortPlus Humidifier or to learn which White Rodgers IAQ products are right for your home contact your local heating and air conditioning contractor Part No 000 0756 314 HBP 6 06 8100 W Florissant A...

Отзывы: