background image

6

REMOVE OLD FILTER AND DISCARD

(Figure 11)

NOTE: This filter may be mounted in the furnace compart-
ment.

CLEAN BLOWER COMPARTMENT

NOTE: The air filter cannot remove dirt from blower and
ducts.

INSTALLATION

The following is a typical installation of the air filter on a
“Highboy” furnace (Figure 7).

1.

Place the air filter compartment on the floor. Stand it
upright with the door facing you (Figure 2). If a
horizontal installation is being planned, lay the com-
partment on its side, this will help you to visualize the
relative location of all parts.

2.

Unscrew the knob, remove the door (by grasping top
and pulling door away from compartment) and set it
aside. Remove 5

 filter. Set in a safe location until the

compartment is installed.

3.

Set the compartment next to the furnace (if possible)
to match the opening in the compartment.

If the furnace opening cannot be enlarged, a transi-
tion fitting should be used. (Figure 3).

The compartment can be attached directly (Figure
12), or a starting collar can first be fitted to the furnace
inlet. A butt or slip joint can be used.

Securely attach the compartment to furnace inlet,
using at least two of the mounting holes on each side
of the compartment.

4.

Using butt joint, attach duct work (normally an elbow)
to the upstream side of air filter compartment. (Note
the use of the sheet metal turning vanes inside the
elbow to improve air distribution.) (Figure 13)

NOTE: 

An optional method of attaching duct work to the

air filter cabinet is to modify the compartment (Figure 14)
by bending the tabs outward at a 90° angle and attaching
duct work to tabs.

Transition Fittings

If the air duct does not fit the compartment opening, a
transition fitting should be used. Gradual transitions are
preferred for greatest efficiency. Not more than four
inches per linear foot (approximately 20° angle) should be
allowed (Figure 3).

5.

Connect the vertical duct section to the elbow. Wedge
a wood block between floor and elbow for support
(Figure 15).

6.

Seal all joints in the return air system downstream
from the air filter with duct tape to prevent dust from
entering the air stream. Tape is usually applied on the
outside of ducts, but may also be applied on the
inside, or both.

INSTALLATION

7.

With the air filter compartment installed, re-install 5

filter and door. (Figure 2)

Figure 11

Air Flow

Turning

Vanes

Figure 13

Optional method

(Bend tabs outward at 90˚ angle)

Figure 14

Содержание Comfort Plus ACB1000

Страница 1: ...el Number ACM ACB OWNER S MANUAL Installation Operation Technical Repair Guide Repair and Upgrade Parts PART NO 37 6383C Replaces 37 6383B 0446 Please read and familiarize yourself with the contents o...

Страница 2: ...ntenance 7 Repair and Upgrade Parts 7 GUARANTEE 1 Read the Owners Manual and the Rules for Safe Operation carefully Failure to follow these rules and instructions could cause a malfunction of filter o...

Страница 3: ...also easy to maintain Its basic components and their functions are as follows See Figure 2 Air Filter Compartment mounts to existing duct work and houses the filters or optional electronic air cleaner...

Страница 4: ...The air filter is not to be placed in the discharge of either the heating or cooling unit 4 IMPORTANT If atomizing spray type humidifier is used it must be installed downstream from the air filter If...

Страница 5: ...ove furnace HIGHBOY FURNACE Figure 7 Side installation Filter is mounted vertically where return air enters side inlet of furnace OFFSET INSTALLATION Figure 9 Typical use of duct offset to match air f...

Страница 6: ...ment to furnace inlet using at least two of the mounting holes on each side of the compartment 4 Using butt joint attach duct work normally an elbow to the upstream side of air filter compartment Note...

Страница 7: ...ive the following information as shown in this list 1 The PART NUMBER 2 The PART DESCRIPTION 3 The MODEL NUMBER of the Air Filter Compart ment Always order by PART NUMBER Not by ITEM NUMBER PARTS LIST...

Страница 8: ...does not extend a warranty directly to consumers White Rodgers does extend a warranty to Wholesalers and Original Equipment Manufacturers who use White Rodgers Products To obtain more information abo...

Страница 9: ...Mod le ACM ACB GUIDE DE L UTILISATEUR Installation Exploitation Guide technique de r paration Pi ces de rechange et de mise niveau PI CE No 37 6383C Remplace 37 6383B 0446 Pri re de lire attentivemen...

Страница 10: ...l purateur risquerait de fonctionner incorrectement ou pas du tout DIRECTIVES D INSTALLATION ET D EXPLOITATION S CURITAIRES 2 Effectuer r guli rement les r visions et l entretien afin d assurer un fon...

Страница 11: ...cellules d purateur lectronique facultatives REMARQUE Pour transformer l purateur en appa reil lectronique efficacit lev e utiliser l ensemble de mise niveau ACR qui convient D tails la page 7 Filtre...

Страница 12: ...NT Si un humidificateur pulv risation est utilis il doit tre install en aval de l purateur S il est impossible d agrandir suffisamment l ouverture du g n rateur d air chaud on doit alors installer une...

Страница 13: ...r G N RATEUR CAISSONS SUPERPOS S figure 7 Installation lat rale Installer l purateur la verticale l o la reprise d air p n tre dans la prise d air lat rale du g n rateur INSTALLATION AVEC D VIATION fi...

Страница 14: ...du bo tier 4 Assembler en bout le conduit de reprise d air habituelle ment une section coud e et la face en amont du bo tier de l purateur Noter dans le coude l utilisation d aubes re courb es en t l...

Страница 15: ...der de la fa on suivante ATTEN TION Il est important de remplacer tous les 90 jours le filtre fibres install dans le bo tier Lorsque le filtre est sale les installations de chauffage et de climatisat...

Страница 16: ...t ge directement les consommateurs Cependant l entreprise garantit ses produits aupr s des grossistes et des fabricants qui les utilisent Pour savoir comment cette garantie peut vous avantager nous vo...

Отзывы: