background image

4

D

C

B

E

A

6 7/8

AIR FLOW

NOT TO EXCEED 20

FURNACE 

OPENING

FURNACE

AIR CLEANER

DUCTWORK

AIR FLOW

THIS CABINET

CAN ACCEPT
ELECTRONIC

AIR CLEANER 

OPTION

(SEE PAGE 7)

AIR CLEANER
OPENING

TRANSITION SECTION (IF NEEDED)

Figure 3

Figure 4

LOCATING THE AIR FILTER

Your air filter must be mounted in the return air duct of a
central forced-air system, on the air entering side of your
furnace. (See Figure 3 for example.)

Select a location that meets the following:

1.

The face of the filter will be at a right angle to the air
stream.

2.

Allow 25

 of clearance in front of the air filter compart-

ment door to permit removal of filters.

See figure 4 for complete compartment dimen-
sions.

3.

The air filter is not to be placed in the discharge of
either the heating or cooling unit.

4.

IMPORTANT:  If atomizing spray type humidifier is
used, it must be installed downstream from the air
filter.

If furnace opening cannot be enlarged to required size, a
transition sheet metal section must be used. Transition
must be planned for each job. Reduction should not be
more than 4 inches per linear foot, approximately 20
angular degrees (Figure 3).

PREINSTALLATION

Model No.

A

B

C

D

E

ACB/ACM1000 20-1/4 12-5/8 13-9/16 16-7/16 19-1/16

ACB/ACM1400 26-1/4 23-5/8 13-9/16 16-7/16 19-1/16

ACB/ACM1600 20-1/4 12-5/8

17-3/4

20-5/8

23-3/8

ACB/ACM2000 26-1/4 23-5/8

17-3/4

20-5/8

23-3/8

Содержание ACB1000

Страница 1: ... S MANUAL Installation Operation Technical Repair Guide Repair and Upgrade Parts PART NO 37 6383A Replaces 846 2032 B 0206 Please read and familiarize yourself with the contents of this manual before installing operating or performing maintenance on the unit White Rodgers is a division of Emerson Electric Co www white rodgers com Printed In U S A ...

Страница 2: ...ion 2 How the Air Filter Works 3 Construction of the Air Filter Compartment 3 Preinstallation 4 Installation 6 Maintenance 7 Repair and Upgrade Parts 7 GUARANTEE 1 Read the Owners Manual and the Rules for Safe Operation carefully Failure to follow these rules and instructions could cause a malfunction of filter or unsatisfactory service RULES FOR SAFE INSTALLATION AND OPERATION 2 Follow a regular ...

Страница 3: ...r air filter compartment easy to install it is also easy to maintain Its basic components and their functions are as follows See Figure 2 Air Filter Compartment mounts to existing duct work and houses the filters or optional electronic air cleaner cells NOTE To upgrade your air filter compartment with a high efficiency Electronic Air Cleaner use the ACR Air Cleaner Retrofit Kit for your model See ...

Страница 4: ...r compart ment door to permit removal of filters See figure 4 for complete compartment dimen sions 3 The air filter is not to be placed in the discharge of either the heating or cooling unit 4 IMPORTANT If atomizing spray type humidifier is used it must be installed downstream from the air filter If furnace opening cannot be enlarged to required size a transition sheet metal section must be used T...

Страница 5: ...bove furnace HIGHBOY FURNACE Figure 7 Side installation Filter is mounted vertically where return air enters side inlet of furnace OFFSET INSTALLATION Figure 9 Typical use of duct offset to match air filter opening If duct connection to furnace allows less than nine inches for mounting the air filter shorten the lateral trunk or attach an offset fitting to the elbow HORIZONTAL FURNACE Figure 10 Fi...

Страница 6: ...tment to furnace inlet using at least two of the mounting holes on each side of the compartment 4 Using butt joint attach duct work normally an elbow to the upstream side of air filter compartment Note the use of the sheet metal turning vanes inside the elbow to improve air distribution Figure 13 NOTE An optional method of attaching duct work to the air filter cabinet is to modify the compartment ...

Страница 7: ...ding it into the compartment Note direction of air flow 4 Replace door When ordering repair parts always give the following information as shown in this list 1 The PART NUMBER 2 The PART DESCRIPTION 3 The MODEL NUMBER of the Air Filter Compart ment Always order by PART NUMBER Not by ITEM NUMBER PARTS LIST FOR AIR FILTER COMPARTMENT REPAIR and UPGRADE PARTS Vertical Section Wood Block Tape All Join...

Страница 8: ...s does not extend a warranty directly to consumers White Rodgers does extend a warranty to Wholesalers and Original Equipment Manufacturers who use White Rodgers Products To obtain more information about how your Wholesaler or Original Equipment Manufacturer s warranty may benefit you please contact your Wholesaler or Original Equipment Manufacturer Sincerely White Rodgers The Emerson logo is a tr...