2

INSTALLATION AND WIRING (cont’d)

HEATING-COOLING THERMOSTAT WITH SWITCHING
SUB-BASE (NOTE: If separate Heating & Cooling
Thermostats are used, SPDT Selector switch must be used.)

*NOTE: HONEYWELL TYPE R8184M USES DUMMY “Y“
AND “G” TERMINALS AS TIE POINTS.

F

F

C

W

RH

RH

W

Y

G

RC

Y*

G*

F

F

C

W

RH

RH

W

Y

G

RC

ORANGE

FLAME
DETECTOR

WIRE
NUTS

INSTALLED
JUMPER

W-R

HEATING-COOLING

THERMOSTAT

W-R TYPE 668-451

WIRING TERMINALS

W-R TYPE 668-451

WIRING TERMINALS

W-R 2-WIRE

HEATING ONLY

THERMOSTAT

IGN.
TRANS.

PRIMARY
CONTROL

WHITE

COOLING

CONTACTOR

FAN RELAY

FLAME
DETECTOR

FLAME
DETECTOR

H-W TYPE R8184M

WIRING TERMINALS

COOLING

CONTACTOR

FAN RELAY

BLACK

LIMIT

LINE

HOT

N

BURNER

MOTOR

F

F

C

W

RH

RH

W

External Line Voltage Wiring

Low Voltage Wiring

Low Voltage

2-Wire Heating Only

All wiring should be done in accordance with local and national electrical codes and ordinances.

TESTING

The following control checks should be made after each
installation to insure that the controls are correctly wired
and functioning properly.
1.

Open the main line switch.

2.

Adjust thermostat or operating control to call for heat.

3.

Operate the manual reset button on top of control.

4.

Make certain that high limit control is set at the correct
temperature.

5.

Open the hand valve in the oil line. The system is now
ready for the following tests.

A. NORMAL CYCLE:

Close the line switch. The burner should start and
continue to run normally. (If burner starts, establish-
ing flame, but then locks out on safety, make “Flame
Detector Check” at this time.)

B. SAFETY TIMING:
1.

Let the burner run for about 5 minutes. Then remove
one of Flame Detector leads from the “F” terminals.
After a time period corresponding to the safety timing
has elapsed, the control should lock out on safety,
stopping the burner.

2.

Open the line switch.

3.

Replace Flame Detector lead removed in step 1.

4.

Wait 3 minutes. Then operate the manual reset button
on top of control.

C. HIGH LIMIT AND THERMOSTAT CHECK:
1.

Close the line switch to start the burner.

2.

Lower the setting of the high limit control to its lowest
setting. This should stop the burner, unless furnace or
boiler temperature is below the minimum setting of the
high limit.

3.

Return high limit control to its proper setting. Burner
should restart.

4.

With the burner running, turn thermostat to its lowest
setting. This should stop the burner, unless actual room
temperature is below the lowest setting of the thermostat.

On systems supplying domestic hot water, burner
will continue to run if low limit control is not
satisfied.

5.

Return thermostat to its proper setting.

D. FLAME DETECTOR CHECK: (This test is not re-

quired if the control performs as described in test A.)

If the burner starts but the control locks out (stopping the
burner), check the flame detector as follows:
1.

Open the line switch.

2.

Connect one end of a wire jumper to one of the “F”
terminals.

3.

Start the burner by closing the line switch. As soon as
the flame has been established, connect the other end
of the wire jumper to the other “F” terminal.

The control provides NO SAFETY PROTECTION
with this jumper installed. DO NOT leave burner
in this condition except for making this check.

If the control still locks out with the jumper installed, the control
should be replaced. If the control does not lock out, however,
check the operation of the 956 flame detector as follows:

NOTE

WARNING

!

Possible Cause of

Trouble

Open circuit in Cell

Flame detector im-
properly positioned

Replace Cell (or Cell Assembly) of
956 Flame Detector. Do not disturb
position of bracket or socket assembly.

Locate flame detector according to the
burner manufacturer’s specifications.

Correction

Содержание 668-451

Страница 1: ...national electrical codes and ordinances This control is a precision instrument and should be handled carefully Rough handling or distorting compo nents could cause the control to malfunction To prevent electrical shock and or equipment damage disconnect electric power to system at mainfuseorcircuitbreakerbox untilinstallation is complete Do not use on circuits exceeding specified volt ages Higher...

Страница 2: ...ing has elapsed the control should lock out on safety stopping the burner 2 Open the line switch 3 Replace Flame Detector lead removed in step 1 4 Wait3minutes Thenoperatethemanualresetbutton on top of control C HIGH LIMIT AND THERMOSTAT CHECK 1 Close the line switch to start the burner 2 Lower the setting of the high limit control to its lowest setting This should stop the burner unless furnace o...

Страница 3: ... other F terminal Burner should continue to run c Withburnerrunning attachflamedetectorleadstoan accurate ohmmeter Reading of ohmmeter should be below 1000 ohms and preferably as low as 500 ohms If indicator of ohmmeter remains steady read ings up to 2000 ohms should also be acceptable Generally the lower the reading the better the application and less likely the chance of burner flame variation c...

Страница 4: ...tre conforme aux codes et règlements locaux et nationaux qui régissent les installations électriques Votre commande est un appareil de précision qui doit être manipulé avec soin Elle peut se détraquer si elle est manipulée defaçonnégligenteousidescomposantessontendommagées Pour prévenir les risques d électrocution et de dommages matériels coupez l alimentation du système au panneau de distribution...

Страница 5: ...de sécurité s est écoulé la commande devrait engager le blocage de sécurité et arrêter le brûleur 2 Ouvrez l interrupteur principal 3 Rebranchez le fil du détecteur de flamme que vous avez débranché à l étape 1 4 Attendez 3 minutes puis appuyez sur le bouton de remise en route manuel qui est situé sur le dessus de la commande C VÉRIFICATION DU LIMITEUR À MAXIMUM ET DU THER MOSTAT 1 Fermez l interr...

Страница 6: ...continuer à fonctionner c Avec le brûleur en marche branchez les fils du détecteur à un ohmmètre juste La lecture devrait être inférieure à 1 000 ohms et se situer de préférence dans les alentours de 500 ohms Si l indicateur de l ohmmètre est stable une lecture allantjusqu à2000 ohmsdevraitêtreacceptable Règle générale cependant une faible résistance entraîne une meilleure installation et diminue ...

Отзывы: