White Rodgers 50M56-743 Скачать руководство пользователя страница 5

5

50M56

TERMINAL

TERMINAL

TYPE

SYSTEM COMPONENT

CONNECTION

TYPICAL SYSTEM WIRING TABLE

 Maximum recommended flame probe wire length is 36 inches.

  

    
    

low voltage thermostat W terminal (or equivalent)
low voltage thermostat G terminal (or equivalent)
low voltage thermostat R terminal (or equivalent)
low voltage thermostat Y terminal (or equivalent)
(2nd wire from Y terminal goes to 24 VAC HOT side of
     compressor contactor coil)
24 VAC COMMON side of compressor contactor coil
high limit OUTPUT
gas valve first stage
24 VAC transformer (low voltage HIGH side)
pressure switch OUTPUT
rollout switch OUTPUT
24 VAC transformer (low voltage COMMON side)
high limit INPUT
MUST BE RELIABLY GROUNDED TO CHASSIS
gas valve COMMON
pressure switch INPUT
rollout switch INPUT
gas valve second stage
inducer HOT side
ignitor HOT side
inducer NEUTRAL side
ignitor NEUTRAL side

W

G

R

Y

C

HLO (Pin 1)

MV LO (Pin 2)

TH (Pin 3)

PSO (Pin 4)

RO OUT (Pin 5)

TR (Pin 6)

HLI (Pin 7)

GND (Pin 8)

MV COM (Pin 9)

PSI (Pin 10)

RO IN (Pin 11)
MV HI (Pin 12)

IND (Pin 1)

IGN (Pin 2)

IND-N (Pin 3)

IGN-N (Pin 4)

COOL

LO HEAT

HI HEAT

PARK (2 terminals)

LINE

XFMR

EAC (optional)

CIR N

LINE N

XFMR N

EAC N (optional)

FS

circulator blower COOL SPEED terminal
circulator blower LO HEAT SPEED terminal
circulator blower HI HEAT SPEED terminal
unused  terminals
input voltage (120 VAC) HOT side
24 VAC transformer line voltage HOT side
electronic air cleaner HOT side
circulator blower NEUTRAL terminal
input voltage (120 VAC) NEUTRAL side
24 VAC transformer line voltage NEUTRAL side
electronic air cleaner NEUTRAL side
flame sensor probe

HLO

PSO

HLI

PSI

GND

TH

TR

MV

LO

RO

OUT

RO

IN

MV

COM

MV

HI

IND

IGN

IND

N

IGN

N

Terminal

 block with 

captive

screws

spade terminal
spade terminal
spade terminal
spade terminal
spade terminal
spade terminal
spade terminal
spade terminal
spade terminal
spade terminal
spade terminal
spade terminal

 

 WIRING

Содержание 50M56-743

Страница 1: ...instructions to ensure proper operation PRECAUTIONS CAUTION Do not short out terminals on gas valve or primary control Short or incorrect wiring may damage the thermostat Failure to comply with the fo...

Страница 2: ...to allow for the dissipation of any unburned gas or residual products of combustion between the failed trial for ignition and the retry period 60 Post Purge The period of time intended to allow for th...

Страница 3: ...ire is recommended for all line voltage connections Afterinstallationorreplacement followappliancemanufacturer s recommended installation or service instructions to ensure proper operation Do not shor...

Страница 4: ...NSFORMER HOT LINE NEUTRAL LINE FS FLAME SENSOR PROBE TH TR RO OUT RO IN TYPICAL SYSTEM WIRING DIAGRAM Low Voltage 24 VAC Line Voltage 120 VAC LEGEND N C Normally closed switch N O Normally open switch...

Страница 5: ...de ignitor NEUTRAL side W G R Y C HLO Pin 1 MV LO Pin 2 TH Pin 3 PSO Pin 4 RO OUT Pin 5 TR Pin 6 HLI Pin 7 GND Pin 8 MV COM Pin 9 PSI Pin 10 RO IN Pin 11 MV HI Pin 12 IND Pin 1 IGN Pin 2 IND N Pin 3 I...

Страница 6: ...ges for comfort Auto will adapt the delay to energize MV HI from instantly to up to 12 minutes When the thermostat is satisfied the gas valve is de energized After proof of flame loss the heat delay t...

Страница 7: ...fault codes stored can be displayed on the diagnostic LED When the control is in standby mode no call for heat or cool press the FAULT RECALL switch for approximately two seconds or until the diagnost...

Страница 8: ...fficient vacuum to engage switch Refer to wiring diagram terminals PSI PSO 4 Open high temperature limit switch Verify continuity through limit switch circuit Refer to wiring diagram terminals HLI HLO...

Отзывы: