To prevent electrical shock and/or equipment
damage, disconnect electric power to system at
main fuse or circuit breaker box until installation
is complete.

Label all wires prior to disconnection when ser-
vicing controls. Wiring errors can cause im-
proper and dangerous operation.

This control is not intended for use in locations
where it may come in contact with water. Suit-
able protection must be provided to shield the
control from exposure to water (dripping, spray-
ing, rain, etc.).

Do not use on circuits exceeding specified volt-
age. Higher voltage will damage control and
could cause shock or fire hazard.

Do not short out terminals on gas valve or pri-
mary control to test. Short or incorrect wiring will
damage thermostat and could cause personal
injury and/or property damage.

Printed in U.S.A.

50A62-820

Integrated Furnace Control

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.

DESCRIPTION

INSTALLATION INSTRUCTIONS

WHITE-RODGERS
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
www.white-rodgers.com

The 50A62-820 is an automatic gas interrupted ignition
control that employs a microprocessor to continually
monitor, analyze, and control the proper operation of the
gas burner, inducer, and fan.

Signals interpreted during continual surveillance of the
thermostat and flame sensing element initiate automatic
ignition of the burner, sensing of the flame, and system
shut-off during normal operation.

These controls incorporate system fault analysis for quick
gas flow shut-off, coupled with automatic ignition retry
upon sensing a fault correction.

WHITE-RODGERS

PRECAUTIONS

Operator: Save these instructions for future use!

GENERAL PRECAUTION

!

CAUTION

!

Application of this type of control may cause
flame rollout on initial start-up and could cause
personal injury and/or property damage.

Replace only with exact model number, includ-
ing dash number. Failure to use exact replace-
ment control could cause personal injury and/or
property damage.

If in doubt about whether your wiring is millivolt, line, or low
voltage, have it inspected by a qualified heating and air
conditioning contractor, or licensed electrician.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical
codes and ordinances.

This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.

WARNING

!

CONTENTS

Description .........................................................  1
Precautions ........................................................  1
Specifications .....................................................  2
Installation ..........................................................  3

Mounting & Wiring

Operation ...........................................................  6

PART NO. 37-6266A

0119

Содержание 50A62-820

Страница 1: ...processor to continually monitor analyze and control the proper operation of the gas burner inducer and fan Signals interpreted during continual surveillance of the thermostat and flame sensing elemen...

Страница 2: ...multipoise Timing Specs 60 Hz maximum Flame Establishing Time 2 sec Flame Failure Response Time 2 sec Gases Approved Natural Manufactured Mixed Liquid Petroleum and LP Gas Air Mixtures are all approv...

Страница 3: ...ted only in a control box of a Lennox furnace The control must be secured to an area that will experi ence a minimum of vibration and remain below the maxi mum ambient temperature rating of 175 F The...

Страница 4: ...LLOUT N C HIGH LIMIT N C PRESSURE SWITCH N O FLAME SENSOR PROBE COMPRESSOR CONTACTOR ELECTRONIC AIR CLEANER HUMIDIFIER INDUCER CIRCULATOR BLOWER 50A62 24 VAC 120 VAC 24 VAC CLASS II TRANSFORMER HOT LI...

Страница 5: ...quivalent low voltage thermostat Y terminal or equivalent 2nd wire from Y terminal goes to 24 VAC HOT side of compressor contactor coil 24 VAC COMMON side of compressor contactor coil gas valve both g...

Страница 6: ...nergized After proof of flameloss theinducerblowerremainsenergizedtopurge the system for 5 seconds When the purge is complete the inducer blower and humidifier are de energized and the delay to fan of...

Страница 7: ...e the flame rollout sensor opens the gas valve and ignitor are de energized 2 If at any time flame is sensed when the gas valve is de energized the heat circulator blower and inducer fan are energized...