50A55

TERMINAL

TERMINAL

TYPE

SYSTEM COMPONENT

CONNECTION

TYPICAL SYSTEM WIRING TABLE

* maximum recommended flame probe wire length is 36 inches.

W

G

R

Y

C

MV (2 terminals)

TR

TH

RO1

RO2

FP

PS

HLI

HLO

GND

(unused terminal)

IND

IGN

COOL

HEAT

PARK (2 terminals)

LINE

XFMR

EAC (optional)

HUM (optional)

CIR N

LINE N

XFMR N

EAC N (optional)

HUM N (optional)

    Terminal

     block with

     captive

     screws

    12-pin

    connector

    & harness

    2-pin
    connector
    & harness

spade terminal

spade terminal

spade terminal

spade terminal

spade terminal

spade terminal

spade terminal

spade terminal

spade terminal

spade terminal

spade terminal

spade terminal

low voltage thermostat W terminal (or equivalent)

low voltage thermostat G terminal (or equivalent)

low voltage thermostat R terminal (or equivalent)

low voltage thermostat Y terminal (or equivalent)

(2nd wire from Y terminal goes to 24 VAC HOT side of

     compressor contactor coil)

24 VAC COMMON side of compressor contactor coil

gas valve (both gas solenoids are connected in parallel)

24 VAC transformer (low voltage COMMON side)

24 VAC transformer (low voltage HIGH side)

rollout switch OUTPUT

rollout switch INPUT

flame sensor probe*

pressure switch INPUT

high limit INPUT

high limit OUTPUT

MUST BE RELIABLY GROUNDED TO CHASSIS

inducer HOT side

ignitor HOT side

circulator blower COOL SPEED terminal

circulator blower HEAT SPEED terminal

unused circulator blower terminals

input voltage (120 VAC) HOT side

24 VAC transformer line voltage HOT side

electronic air cleaner HOT side

humidifier HOT side

circulator blower NEUTRAL terminal

input voltage (120 VAC) NEUTRAL side

24 VAC transformer line voltage NEUTRAL side

electronic air cleaner NEUTRAL side

humidifier NEUTRAL side

Содержание 50A55-285

Страница 1: ...er and fan Signals interpreted during continual surveillance of the thermo stat and flame sensing element initiate automatic ignition of the burner sensing of the flame and system shut off during norm...

Страница 2: ...Establishing Time 0 8 sec Flame Failure Response Time 2 0 sec At 50 Hz all timing specifications should be increased by 20 Gases Approved Natural Manufactured Mixed Liquified Petroleum and LP Gas Air...

Страница 3: ...rminals to mate with those on the control UL approved 105 C rated 16 gauge min stranded 4 64 thick insulation wire is recommended for all line voltage connections Refer to 50A55 specification sheet fo...

Страница 4: ...N C ROLLOUT N C AUX HIGH LIMIT N C PRESSURE SWITCH N O FLAME SENSOR PROBE COMPRESSOR CONTACTOR ELECTRONIC AIR CLEANER HUMIDIFIER INDUCER CIRCULATOR BLOWER 50A55 24 VAC 120 VAC 24 VAC CLASS II TRANSFOR...

Страница 5: ...al or equivalent low voltage thermostat Y terminal or equivalent 2nd wire from Y terminal goes to 24 VAC HOT side of compressor contactor coil 24 VAC COMMON side of compressor contactor coil gas valve...

Страница 6: ...ed the ignitor is turned off and the 50A55 control goes into the retry se quence The retry sequence provides a 60 second wait follow ing an unsuccessful ignition attempt flame not detected After this...

Страница 7: ...tomatically reset itself DIAGNOSTIC FEATURES The 50A55 control continuously monitors its own operation and the operation of the system If a failure occurs the LED will indicate a failure code as shown...

Страница 8: ...MOUNTING HOLE TEMPLATE FOR MOUNTING HOLE LOCATIONS 4 172 007 2 plcs 6 402 010 2 plcs Refer to page 3 of the installation instructions for proper installation MOUNTING HOLE TEMPLATE...

Отзывы: