FIRE HAZARD

• Do not exceed the specified voltage.
• Replace existing control with exact model and

dash number.

• Protect the control from direct contact with water

(dripping, spraying, rain, etc.).

• If the control has been in direct contact with water,

replace the control.

• Label all wires before disconnection when servic-

ing controls. Wiring errors can cause improper
and dangerous operation.

• Route and secure wiring away from flame.

SHOCK HAZARD

• Disconnect electric power before servicing .
• Ensure proper earth grounding of appliance.
• Ensure proper connection of line neutral and line

hot wires.

EXPLOSION HAZARD

• Shut off main gas to appliance until installation is

complete.

Printed in U.S.A.

50A55-285

Integrated Furnace Control

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.

DESCRIPTION

Operator: Save these instructions for future use!

INSTALLATION INSTRUCTIONS

WHITE-RODGERS
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
www.white-rodgers.com

The 50A55-285 is an automatic gas interrupted ignition control
that employs a microprocessor to continually monitor, analyze,
and control the proper operation of the gas burner, inducer, and
fan.

Signals interpreted during continual surveillance of the thermo-
stat and flame sensing element initiate automatic ignition of the
burner, sensing of the flame, and system shut-off during normal
operation.

PRECAUTIONS

PART NO. 37-6100C

Replaces 37-6100B

0150

Installation should be done by a qualified heating and air
conditioning contractor or licensed electrician.

If in doubt about whether your wiring is millivolt, line, or low
voltage, have it inspected by a qualified heating and air condi-
tioning contractor or licensed electrician.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and
ordinances.

This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.

Following installation or replacement, follow manufacturer’s
recommended installation/service instructions to ensure proper
operation.

CONTENTS

Description .........................................................  1
Precautions ........................................................  1
Specifications .....................................................  2
Installation ..........................................................  3

Mounting & Wiring

Operation ...........................................................  6
Mounting Hole Template ..................................... 8

These controls incorporate system fault analysis for quick gas
flow shut-off, coupled with automatic ignition retry upon sensing
a fault correction.

WARNING

Failure to comply with the following 
warnings could result in personal injury 
or property damage.

CAUTION

Do not short out terminals on gas valve or primary
control. Short or incorrect wiring may damage the
thermostat.

Содержание 50A55-285

Страница 1: ...er and fan Signals interpreted during continual surveillance of the thermo stat and flame sensing element initiate automatic ignition of the burner sensing of the flame and system shut off during norm...

Страница 2: ...Establishing Time 0 8 sec Flame Failure Response Time 2 0 sec At 50 Hz all timing specifications should be increased by 20 Gases Approved Natural Manufactured Mixed Liquified Petroleum and LP Gas Air...

Страница 3: ...rminals to mate with those on the control UL approved 105 C rated 16 gauge min stranded 4 64 thick insulation wire is recommended for all line voltage connections Refer to 50A55 specification sheet fo...

Страница 4: ...N C ROLLOUT N C AUX HIGH LIMIT N C PRESSURE SWITCH N O FLAME SENSOR PROBE COMPRESSOR CONTACTOR ELECTRONIC AIR CLEANER HUMIDIFIER INDUCER CIRCULATOR BLOWER 50A55 24 VAC 120 VAC 24 VAC CLASS II TRANSFOR...

Страница 5: ...al or equivalent low voltage thermostat Y terminal or equivalent 2nd wire from Y terminal goes to 24 VAC HOT side of compressor contactor coil 24 VAC COMMON side of compressor contactor coil gas valve...

Страница 6: ...ed the ignitor is turned off and the 50A55 control goes into the retry se quence The retry sequence provides a 60 second wait follow ing an unsuccessful ignition attempt flame not detected After this...

Страница 7: ...tomatically reset itself DIAGNOSTIC FEATURES The 50A55 control continuously monitors its own operation and the operation of the system If a failure occurs the LED will indicate a failure code as shown...

Страница 8: ...MOUNTING HOLE TEMPLATE FOR MOUNTING HOLE LOCATIONS 4 172 007 2 plcs 6 402 010 2 plcs Refer to page 3 of the installation instructions for proper installation MOUNTING HOLE TEMPLATE...

Отзывы: