background image

To prevent electrical shock and/or equipment
damage, disconnect electric power to system at
main fuse or circuit breaker box until installation
is complete.

Label all wires prior to disconnection when ser-
vicing controls. Wiring errors can cause im-
proper and dangerous operation.

This control is not intended for use in locations
where it may come in contact with water. Suit-
able protection must be provided to shield the
control from exposure to water (dripping, spray-
ing, rain, etc.).

Do not use on circuits exceeding specified volt-
age. Higher voltage will damage control and
could cause shock or fire hazard.

Do not short out terminals on gas valve or pri-
mary control to test. Short or incorrect wiring will
damage thermostat and could cause personal
injury and/or property damage.

Printed in U.S.A.

50A55-143

Integrated Furnace Control

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.

DESCRIPTION

Operator: Save these instructions for future use!

INSTALLATION INSTRUCTIONS

WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398

The 50A55-143 is an automatic gas interrupted ignition
control that employs a microprocessor to continually
monitor, analyze, and control the proper operation of the
gas burner, inducer, and fan.

Signals interpreted during continual surveillance of the
thermostat and flame sensing element initiate automatic
ignition of the burner, sensing of the flame, and system
shut-off during normal operation.

These controls incorporate system fault analysis for quick
gas flow shut-off, coupled with automatic ignition retry
upon sensing a fault correction.

WHITE-RODGERS

PRECAUTIONS

PART NO. 37-6095A

9919

Application of this type of control may cause
flame rollout on initial start-up and could cause
personal injury and/or property damage.

Replace only with exact model number, includ-
ing dash number. Failure to use exact replace-
ment control could cause personal injury and/or
property damage.

If in doubt about whether your wiring is millivolt, line, or low
voltage, have it inspected by a qualified heating and air
conditioning contractor or licensed electrician.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical
codes and ordinances.

This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.

GENERAL PRECAUTION

!

CAUTION

!

WARNING

!

CONTENTS

Description .........................................................  1
Precautions ........................................................  1
Specifications .....................................................  2
Installation ..........................................................  3

Mounting & Wiring

Operation ...........................................................  6

Содержание 50A55-143

Страница 1: ...pted ignition control that employs a microprocessor to continually monitor analyze and control the proper operation of the gas burner inducer and fan Signals interpreted during continual surveillance...

Страница 2: ...ty non condensing MOUNTING Surface mount multipoise Timing Specs 60 Hz maximum Flame Establishing Time 0 8 sec Flame Failure Response Time 2 0 sec At 50 Hz all timing specifications should be increase...

Страница 3: ...holes for mounting control To ensure proper mounting hole locations there is a mount ing hole template on page 8 of this instruction sheet Detach the page with the template from the instruction sheet...

Страница 4: ...H LIMIT N C PRESSURE SWITCH N O FLAME SENSOR PROBE COMPRESSOR CONTACTOR ELECTRONIC AIR CLEANER HUMIDIFIER INDUCER CIRCULATOR BLOWER 50A55 24 VAC 120 VAC 24 VAC CLASS II TRANSFORMER HOT LINE NEUTRAL LI...

Страница 5: ...alent low voltage thermostat Y terminal or equivalent 2nd wire from Y terminal goes to 24 VAC HOT side of compressor contactor coil one wire twinning terminal 24 VAC COMMON side of compressor contacto...

Страница 6: ...s valve is de energized After proof of flame loss the heat delay to fan off period begins and the inducer blower remains energized to purge the system for 5 seconds When the purge is complete the indu...

Страница 7: ...reversed improper ground 7 flashes then pause Low flame sense signal Continuous flashing Flame has been sensed when no pause no flame should be present no call for heat The LED will also flash once at...

Страница 8: ...MOUNTING HOLE TEMPLATE FOR MOUNTING HOLE LOCATIONS 4 172 007 2 plcs 6 402 010 2 plcs Refer to page 3 of the installation instructions for proper installation...

Отзывы: