Press the SYSTEM button until 

OFF 

is displayed, then press the 

 and 

 simultaneously

INSTALLER/CONFIGURATION MENU

Press

Displayed

Press 

 or 

Step

Button(s)

(Factory Default)

to select

Comments

1

System

MS 2

SS1, HP2, HP1

Selects Single Stage, Multi-Stage, or Heat Pump

(Single Stage or 2-stage) System Configuration

2

System

PRG 4

PRG 0, PRG 2

Selects Programmable Periods

3

System

4:00 HOLD

0:15 to 8:00

Selects Temporary Program Override Time

(increments of 15 minutes)

4

System

EMR

OFF

Selects Energy Management Recovery 

OFF 

or 

ON

(ON)

5

System

FA

SL

Selects Fast or Slow Cycle Selection

6

System

CL

CL

Selects Compressor Lockout 

CL OFF

 or 

ON

(OFF)

(ON)

7

System

CDL

CDL

Selects Backlight Display

(ON)

(OFF)

8

System

FA

FA

Selects Fast Second Stage 

ON 

or 

OFF

(ON)

(OFF)

(Not available if SS1 is selected above)

9

System

0 FLTR

50-1950

 (increments of 50)

Selects filter replacement run time

10

System

0°F

4 LO to 4 HI

Selects Temperature Display Adjustment 

4 LO

 to 

4 HI

(Room Temperature)

11

System

°F

°C

Selects temperature display 

F° 

or 

°C

 selection

12

System

AU On

OFF

Selects AUTO Mode ON or OFF

13

System

LR

LR 62 to LR89

Selects Limited 

HEAT 

range

(90)

14

System

LR

LR 46 to LR 82

Selects Limited COOL range

(45)

15

System

(ON)

Selects Keypad Lockout

(OFF)

16

System

000

001 to 999

Selects Keypad lockout combination number

Press System to set code

17

Run

Returns to the OFF position

CONFIGURA

CONFIGURA

CONFIGURA

CONFIGURA

CONFIGURATION  MENU

TION  MENU

TION  MENU

TION  MENU

TION  MENU

tem key selection will skip EMR (item 4) and temporary
program override (item 3).

3)

Select Temporary Program Override Time

 – The thermo-

stat can hold any temperature you set it to for the amount
of time you select on this option. Your choices are 0:15 to
8:00 hours in 15 minute increments.

Example:

a. You have selected 3:00 hours for the Temporary Pro-

gram Override time period.

b. With the thermostat set to Heat or Cool, press 

 or 

to set the temperature to your preference.
The thermostat will maintain this temperature setting
for 3 hours with 

“HOLD” 

blinking to remind you it is

in Temporary Hold. After 3 hours, the thermostat will

go back to the program temperature and 

“HOLD” 

will

no longer blink or display.

4)

Select Energy Management Recovery OFF or ON

  –

Energy Management Recovery (EMR) causes the thermo-
stat to start heating or cooling early to make the building
temperature reach the program setpoint at the time you
specify. Heating will start 5 minutes early for every 1°
of temperature required to reach setpoint. Cooling allows
more time per degree because it takes longer to reach
temperature.

Example:

 You select EMR and have your heating program-

med to 65° at night and 70° at 7 AM. If the building temp-
erature is 65° the difference between 65° and 70° is 5°.
Allowing 5 minutes per degree the thermostat setpoint will
change to 70° at 6:35 AM.

Содержание 1F85-275

Страница 1: ...r hinge type b The base which is removed by loosening all captive screws c The switching subbase which is removed by unscrewing the mounting screws that hold it on the wall or adaptor plate 3 Remove the front cover of the old thermostat With With With With With wires wires wires wires wires still attached still attached still attached still attached still attached remove wall plate from the wall I...

Страница 2: ...personal injury and or thermostat and could cause personal injury and or thermostat and could cause personal injury and or thermostat and could cause personal injury and or thermostat and could cause personal injury and or property damage property damage property damage property damage property damage Thermostat installation and all components of the system shall conform to Class II circuits per t...

Страница 3: ...d Stage Emergency Mode 2nd Stage Emergency Mode 1st Stage 24 Volt Common Fault Indicator or System Malfunc tion Switch 24 Volt Hot System B O Y2 Y1 G W2 E W1 C L R CLASS II TRANSFORMER HOT 24VAC NEUTRAL 120VAC NOTE If your system does not provide an E connection jumper W2 to E W1 to use the Auxiliary Heat in the Emergency Mode Figure 2 Heat Pump Systems Single Stage 1 SS1 Multi Stage 2 MS2 Energiz...

Страница 4: ...rature The heating system should begin to operate The display should show STG1 However if the setpoint temperature display is flashing the compres sor lockout feature is operating see Configuration menu item 5 3 Adjust temperature setting to 3 above room temperature If your system configuration is set at MS2 HP2 or HP1 the auxiliary heat system should begin to operate and the display should show S...

Страница 5: ...change or clean your filter 16 Display when in keypad lockout mode 17 EMER is displayed flashing when the system is in EMER mode 18 The word FAULT will be displayed when there is a malfunction in the HEAT COOL system 19 Display when limited HEAT COOL range is activated The icon will flash if an attempt is made to adjust the temperature beyond the limited HEAT COOL temperature range 20 Stage1 2 ind...

Страница 6: ... Press System to set code 17 Run Returns to the OFF position CONFIGURA CONFIGURA CONFIGURA CONFIGURA CONFIGURATION MENU TION MENU TION MENU TION MENU TION MENU tem key selection will skip EMR item 4 and temporary program override item 3 3 Select Temporary Program Override Time The thermo stat can hold any temperature you set it to for the amount of time you select on this option Your choices are 0...

Страница 7: ...de to defeat the auto changeover mode OFF 13 Limited Heat Range This feature provides a maximum setpoint temperature for heat The default setting is 90 F It can be changed between 62 F and 89 F by pressing the or key 14 Limited Cool Range This feature provides a minimum setpoint temperature for cool The default setting is 45 F It can be changed between 46 F and 82 F by pressing the or key 15 16 Ke...

Страница 8: ...e thermostat will automatically revert to the program after programmed period LOW BATTERY INDICATOR LOW BATTERY INDICATOR LOW BATTERY INDICATOR LOW BATTERY INDICATOR LOW BATTERY INDICATOR If the 2 AA alkaline batter ies are low and should be replaced the display will be blank except for LO BATT LO BATT LO BATT LO BATT LO BATT We recommend replacing batteries every 2 years If the home is going to b...

Страница 9: ...or until your selected start time appears The time will change in 15 minute increments When your selected time is displayed press TIME again to return to the change temperature mode 5 Press PRGM once The currently programmed start time and setpoint temperature for the 2nd heatingpro gram period will appear 6 Repeat steps 3 and 4 to select the start time and heating temperature for the 2nd heating ...

Страница 10: ...the heating is operating correctly TR TR TR TR TROUBLESHOO OUBLESHOO OUBLESHOO OUBLESHOO OUBLESHOOTING TING TING TING TING Reset Operation Reset Operation Reset Operation Reset Operation Reset Operation If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation you can reset the thermo stat by removing the wires from terminals R R R R R and C C C C C and r...

Страница 11: ...ove If the condition persists the manufacturer of your system or service person can instruct you on how to test the Heat Cool system for correct operation If the system operates correctly replace the thermostat Digital thermostats normally provide precise temperature control and may cycle faster than some older mechanical models A faster cycle rate means the unit turns on and off more frequently b...

Страница 12: ...at the AM or PM settings are correct for each period Also verify that the Day of the week is set correctly Models with EMR Energy Management Recovery start early to make the temperature they are programmed for by the time specified in the program See the CONFIGURATION MENU on page 6 step 3 Any time you wish to turn your system off simply press the SYSTEM button until OFF is displayed This will not...

Отзывы: