CHECK THERMOSTAT OPERATION

CONTINUED FROM PAGE 4

5

1

Step

Press Button(s)

Displayed 

Press         

(Factory Default)

to select:

2

HP

4*

Configuration Menu

3

Set SYSTEM

switch to OFF

no HP

and

for at least 2 seconds

and

momentarily

and

momentarily

SL

FA

OFF

L

(ON)

˚C

˚F

5

OFF

7

6

CL

(OFF)

3 LO TO

3 HI

FA

(ON)

and

momentarily

and

momentarily

and

momentarily

ON

0 HI

(0)

8

and

momentarily

* Not available on earlier models.

ELECTRICAL DATA

Electrical Rating:

20 to 30 VAC 50/60 Hz.
0.05 to 1.0 Amps (Load per terminal)

1.5 Amps Maximum Total Load

 (All terminals combined)

THERMAL DATA

Setpoint Temperature Range:

45

°

F to 90

°

F (7

°

C to 32

°

C)

Operating Ambient Temperature Range:

32

°

F to 105

°

F

Operating Humidity Range:

0 to 90% RH (non-condensing)

Shipping Temperature Range:

-40

°

F to 150

°

F

SPECIFICATIONS

6

Configuration Menu

The configuration menu allows you to set certain thermostat
operating characteristics to your system or personal requirements.

The menu mode may be exited by pressing the system key to
change from the OFF mode or after 15 minutes has elapsed with
no keypad activity.

2.   

Multi-stage or Heat Pump Output Configuration

 – This control

can be configured for Heat Pump or two stage heat/two stage
cool multi-stage operation. The display indicates 

no HP

 (de-

fault for multi-stage mode) in the display. The Multi-stage
configuration can be toggled to 

HP

 (Heat Pump mode) by

pressing the 

Temperature Up

 or 

Temperature Down

 key. In

Multi-stage configuration, system key selection will skip

EMER

gency mode.

3.   

Fast or Slow Cycle Selection

 – The factory default setting is

fast cycle, which cycles 1st stage at approximately 1.2˚F and
2nd stage 0.75˚F. If you prefer slow cycle, press the tempera-
ture key to change to SL. The 1st stage and 2nd stage would
be 1.5˚F and 1.2˚F respectively.

4.   

Select backlit display

 – (Not available on earlier models.) The

display backlight improves display contrast in low lighting
conditions. Selecting backlight ON will keep the light on con-
tinuously. Selecting backlight OFF will keep the light off.

5.   In the run mode, if the setpoint temperature is manually raised

by 3

°

F (2

°

C) or more above the actual temperature with the

TEMPERATURE UP

 key, and the fast second stage feature is

enabled, FA on, the second stage will energize immediately.
With FA off, second stage will not energize until the setpoint
temperature is 1

°

F or more above actual temperature for more

than ten minutes.

6.  

Select Compressor Lockout CL OFF or ON

 – Selecting CL

ON will cause the thermostat to wait 5 minutes before turning
on the compressor if the heating and cooling system loses
power. It will also wait 5 minutes minimum between cooling and
heating cycles. This is intended to help protect the compressor
from short cycling. Some newer compressors already have a
time delay built in and do not require this feature. Your com-
pressor manufacturer can tell you if the lockout feature is
already present in their system. When the thermostat compres-
sor time delay occurs it will flash the 

Snowflake 

and 

Flame

Icons

 for about five minutes.

7.  

Select Temperature Display Adjustment 3 LO to 3 HI 

Allows you to adjust the room temperature display up to 3

°

 higher

or lower. Your thermostat was accurately calibrated at the
factory but you have the option to change the display temperature
to match your previous thermostat. The current or adjusted
room temperature will be displayed on the left side of the display.

8.  

˚F or ˚C Selection 

– The factory default setting for temperature

display is Fahrenheit. If you want the temperature in Celcius,
press temperature key to change to ˚C.

9

Displays currently programmed set temperature (this is blank
when SYSTEM switch is in the OFF position).

10

Stage 1 & 2 Indicators:

 The thermostat shall indicate when

the first and second stage is energized except in emergency
mode. The icon is 

STG 1

 for the first stage energized. The

icons for the first and second stage energized are 

STG1+2

located in the lower right side of the display.

OPERATION

The system “mode” is selected by pressing the system key. Icons
on the bottom right corner of the display will indicate the mode;
COOL ( ), AUTO (   ), HEAT ( ), EMER, or OFF. In any mode
except OFF, the setpoint temperature will be shown on the right
side of the display. In OFF, this area will be blank. The current
temperature will be displayed on the left side of the display.

To operate properly in the AUTO mode, the heat setpoint tempera-
ture cannot be the same as or higher than the cool setpoint
temperature. The heat setpoint must be at least 1˚ lower than the
cool setpoint. If you are unable to raise the setpoint temperature
in HEAT or lower the setpoint temperature in COOL, you may be
at the 1˚ difference. To obtain the temperature you wish to set,
change to the opposite mode and move that setpoint away from
your temperature.

7

www.white-rodgers.com

Содержание 1F73

Страница 1: ...old thermostat one at a time DO NOT LET WIRES FALL BACK INTO THE WALL 6 Install new thermostat using the following procedures To prevent electrical shock and or equipment damage disconnect electrical power to the system at the main fuse or circuit breaker until installation is complete CAUTION PART NO 37 6489B Replaces 37 6489A 0621 Failure to follow and read all instructions carefully before inst...

Страница 2: ...ich require the changeover relay to be energized in COOL If the thermostat you are replacing or the heat pump being installed with this thermostat requires a B terminal to energize the changeover relay in HEAT the O B switch must be moved to the B position For multi stage the switch must be in O position for Y2 to operate properly Attach Thermostat Base to Wall 1 Remove the packing material from t...

Страница 3: ...ty Switches 24 VAC Limit or Safety Switches COMMON COMMON Auxiliary Heating Transformer Class II Current Limited Heat Pump Transformer Class II Current Limited 24 VAC ACCESSORY RELAY N O CONTACT Polarity must be observed If the HOT side of the second transformer is jumpered to the COMMON side of the first transformer a short will be made Damage to equipment will occur when power is restored NOTE T...

Страница 4: ...rers instructions for specific sys tem wiring informtion You can configure the thermostat for use with the following heat pump system types HEAT PUMP TYPE 1 Single stage compressor system gas or electric backup This thermostat is designed to operate a single transformer system If you have a two transformer system cut and tape of one Heat Pump Terminal Outputs transformer If transformer safety circ...

Страница 5: ...operate The Flame icon will display flashing to indicate that the Aux system is operating 3 Press to adjust the thermostat below room temperature The Aux heating system should stop operating To prevent compressor and or property damage if the outdoor temperature is below 50 F DO NOT operate the cooling system Cooling System 1 Press SYSTEM key to select the Snowflake icon 2 Press to adjust thermost...

Страница 6: ...gize until the setpoint temperature is 1 F or more above actual temperature for more than ten minutes 6 Select Compressor Lockout CL OFF or ON Selecting CL ON will cause the thermostat to wait 5 minutes before turning on the compressor if the heating and cooling system loses power It will also wait 5 minutes minimum between cooling and heating cycles This is intended to help protect the compressor...

Страница 7: ...ection to thermostat or system Verify thermostat and system wires are securely attached 3 Cooling system requires service or Same procedure as diagnostic for No Heat thermostat requires replacement condition except set the thermostat to COOL and lower the setpoint below the room temperature There may be up to a five minute delay before the thermostat clicks in Cooling Heat Cool or Fan Runs Constan...

Страница 8: ...g requires The thermometer can be adjusted 3 degrees Thermometer Disagree adjustment See Temperature Display Adjustment in the Operation section Blank Display and or Keypad Not 1 Voltage spike or static discharge Use the Reset Operation listed above Responding Heat Setpoint Will Not Respond 1 The desired setpoint conflicts with the Change system mode to COOL Raise the Cool to the Temperature Up Ke...

Отзывы: