White Mountain Hearth VFSR-16-3, VFSR-18-3, VFSR-24-3, VFSR-30-3, VFSV-16-3, VFSV-18-3, VFSV-24-3, VFSV-30-3, VFSM-18-3, VFSM-24-3, VFSM-30-3 Скачать руководство пользователя страница 20

Page 20

15994-2-0504

Index

   Part

  No.

Number

Description

COMMON PARTS

1

15425

REAR LOG SUPPORT (16)

1

15426

REAR LOG SUPPORT (18)

1

15427

REAR LOG SUPPORT (24)

1

15428

REAR LOG SUPPORT (30)

2

11285

BURNER SUPPORT - LEFT (16)

2

11376

BURNER SUPPORT - LEFT
(18,24,30)

3

P-200

ORIFICE FITTING

4

P-204

ORIFICE - LP (VFSR-16 VFSV-16)

4

P-256

ORIFICE - NAT (VFSR-16 VFSV-
16)

4

P-250

ORIFICE - LP (VFSR-18 VFSV-18
VFSM-18)

4

P-203

ORIFICE - NAT (VFSM-18)

4

P-243

ORIFICE - NAT (VFSR-18 VFSV-
18)

4

P-245

ORIFICE - LP (VFSR-24 VFSV-24
VFSM-24)

4

P-244

ORIFICE - NAT (VFSR-24 VFSV-24
VFSM-24)

4

P-265

ORIFICE - LP (VFSR-30 VFSV-30
VFSM-30)

4

P-209

ORIFICE - NAT (VFSM-30)

4

P-211

ORIFICE - NAT (VFSR-30 VFSV-
30)

5

R-5676

AIR SHUTTER - NAT

5

R-5675

AIR SHUTTER - LP

7

11833

PILOT SHIELD (NAT ONLY)

9

12347

BURNER ASSEMBLY (16) NAT

9

12348

BURNER ASSEMBLY (16) LPG

9

14033

BURNER ASSEMBLY (18)

9

14035

BURNER ASSEMBLY (24)

9

14037

BURNER ASSEMBLY (30)

NS

12389

CERAMIC MEDIA

NS

15998

ROCK WOOL (16)

NS

15999

ROCK WOOL (18)

NS

15970

ROCK WOOL (24,30)

NS

11788

DECORATIVE ROCK (2 REQ’D)

NS

R-2809

DAMPER CLAMP (INCLUDED IN
HARDWARE PACKAGE)

MILLIVOLT SYSTEM

6

R-3624

PILOT NAT

6

R-3623

PILOT LP

8

R-7063

PILOT REGULATOR (NAT ONLY)

10

11286

BURNER SUPPORT - RIGHT (16)

10

11375

BURNER SUPPORT - RIGHT
(18,24,30)

11

R-4323

GAS VALVE NATURAL

11

R-4324

GAS VALVE LPG

NS

11292

TUBING - VALVE TO PILOT - LPG

NS

14039

TUBING - VALVE TO PILOT
REGULATOR - NAT

Index

   Part

  No.

Number

Description

Attention: 

When ordering parts, it is very important that 

part number

 and 

description

 of part coincide.

USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.

NS

14041

TUBING - PILOT REGULATOR TO
PILOT - NAT

NS

11291

TUBING - VALVE TO BURNER

NS

R-5668

IGNITOR WIRE

NS

R-5910

SWITCH LOG ASSEMBLY
(INCLUDES SWITCH AND WIRE)

NS

R-5757

OFF/ON SWITCH

NS

R-5699

WIRE HARNESS

VARIABLE SYSTEM

6

R-5170

PILOT LP

6

R-5171

PILOT NAT

8

R-7063

PILOT REGULATOR (NAT ONLY)

10

11333

BURNER SUPPORT - RIGHT (16)

10

11308

BURNER SUPPORT - RIGHT
(18,24,30)

12

R-5672

GAS VALVE NATURAL

12

R5673

GAS VALVE LPG

NS

11335

TUBING - VALVE TO PILOT-LPG

NS

14040

TUBING - VALVE TO PILOT
REGULATOR - NAT

NS

14041

TUBING - PILOT REGULATOR TO
PILOT - NAT

NS

11291

TUBING - VALVE TO BURNER

NS

R-5797

REMOTE KIT

MANUAL SYSTEM

6

R-5170

PILOT LP

6

R-5171

PILOT NAT

10

11481

BURNER SUPPORT - RIGHT

13

15414

REGULATOR MOUNTING
BRACKET

14

R-2480

INLET REGULATOR - LP

14

R-2479

INLET REGULATOR - NAT

15

R-2313

PIEZO IGNITOR

16

R-2783

CONTROL KNOB

17

15416

VALVE BRACKET

18

R-4499

GAS VALVE - LP

18

R-4495

GAS VALVE - NAT

19

15494

COVER PLATE

NS

R-5668

IGNITOR WIRE

NS

15528

TUBING ASSEMBLY - INLET
REGULATOR TO VALVE

NS

15529

TUBING - VALVE TO BURNER

NS

15530

TUBING - VALVE TO PILOT-LPG

NS

15531

TUBING - VALVE TO PILOT
REGULATOR - NAT

NS

15532

TUBING - PILOT REGULATOR TO
PILOT - NAT

PARTS LIST

Содержание VFSR-16-3, VFSR-18-3, VFSR-24-3, VFSR-30-3, VFSV-16-3, VFSV-18-3, VFSV-24-3, VFSV-30-3, VFSM-18-3, VFSM-24-3, VFSM-30-3

Страница 1: ...0 BTU s 3KW s of gas input per hour Refer to page 6 VFSV 16 3 VFSV 18 3 VFSV 24 3 VFSV 30 3 VFSM 18 3 VFSM 24 3 VFSM 30 3 VFSR 16 3 VFSR 18 3 VFSR 24 3 VFSR 30 3 WARNINGS If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flam mable vapors and liquids in the vicinity ...

Страница 2: ...Preparation 9 Installing as a Vented Appliance 10 Before Fully Installing the Appliance 10 Gas Supply 11 Placement of Glowing Embers and Lava Rock 12 Operation Instructions Flame Appearance 12 VFSR 16 18 24 30 Lighting Instructions 13 VFSV 16 18 24 30 Lighting Instructions 14 VFSM 18 24 30 Lighting Instructions 15 Pilot Flame Characteristics 16 17 Cleaning and Servicing 17 Wiring 18 Troubleshootin...

Страница 3: ...of this appliance in a vented configuration Check your state or local codes Correct installation of logs proper location of the heater and annual cleaning are necessary to avoid potential prob lems with sooting Sooting resulting from improper instal lation or operation can settle on surfaces outside the fire place Avoid any drafts that could alter burner flame patterns Do not allow fans to blow di...

Страница 4: ...m service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls of new cylinders and tanks is possible Therefore people should be particularly alert and careful when new tanks or cylinders are placed in service Odor fade can occur in new tanks or reinstalled old tank...

Страница 5: ...atural Manual 32 000 27 000 22 000 VFSM 18 Propane Manual 32 000 27 000 22 000 VFSV 24 Natural Variable 36 000 20 000 VFSV 24 Propane Variable 36 000 20 000 VFSR 24 Natural Millivolt 36 000 25 000 VFSR 24 Propane Millivolt 36 000 25 000 VFSM 24 Natural Manual 36 000 27 000 22 000 VFSM 24 Propane Manual 36 000 27 000 22 000 VFSV 30 Natural Variable 38 000 20 000 VFSV 30 Propane Variable 38 000 20 0...

Страница 6: ...ter Immediately call a qualified service technician to inspect the room heater and replace any part of the control system and any gas control which has been under water WARNING This appliance is equipped for natural or propane gas Field conversion is not permitted Before you get started Carefully inspect the contents for shipping damage If any parts are missing or damaged immediately inform the de...

Страница 7: ...tmosphere have a continuous water vapor retarder with a rating of one perm or less with openings gasketed or sealed and b Weatherstripping has been added on openable windows and doors and c Caulking or sealants are applied to areas such as joints around window and door frames between sole plates and floors be tween wall ceiling joints between wall panels at penetrations for plumbing electrical and...

Страница 8: ...tend at least 8 above fireplace opening With sheet metal you must have non combustible material behind it Heat resistant materials such as slate and marble must be at least 1 2 thick Sheet metal should not be installed onto combustible material Example A mantel may project from the wall a maximum of 2 at a minimum of 13 1 2 above the opening and a maximum of 6 at a mini mum of 15 above the opening...

Страница 9: ... 8 14 5 25 6 6 9 6 12 6 30 6 2 9 1 11 3 35 5 7 8 0 10 8 40 5 3 7 5 10 2 Height is from hearth to top of chimney and the minimum height is 10 feet Chart shows minimum opening sq in for given height and input rate FOR MASONRY BUILT FIREPLACES FREE OPENING AREA OF CHIMNEY DAMPER FOR VENT ING COMBUSTION PRODUCTS FROM DECORATIVE APPPLIANCES FOR INSTALLATION IN SOLID FUEL BURN ING FIREPLACES Appliance I...

Страница 10: ...ING THE APPLIANCE Turn off the gas supply to the fireplace or firebox Seal any fresh air vents and or ash clean out doors located on the floor or wall of the fireplace If left unsealed drafting may cause pilot outage or sooting Use a heat resistant sealant Do not seal the chimney flue damper Before installing in a solid fuel burning fireplace the chimney flue and firebox must be cleaned of soot cr...

Страница 11: ... Never pres sure test with appliance connected control valve will sus tain damage A gas valve and ground joint union should be installed in the gas line upstream of the gas control to aid in servicing It is required by the National Fuel Gas Code that a drip line be installed near the gas inlet This should consist of a vertical length of pipe tee connected into the gas line that is capped on the bo...

Страница 12: ...ould last 2 3 hours with the burner at the highest setting Provide maximum ventilation by opening windows or doors to allow odors to dissipate Any odors remaining after this initial break in will be slight and will disappear with continued use OPERATION INSTRUCTIONS FLAME APPEARANCE Variable Figure 13 Millivolt Figure 14 Manual Figure 15 PLACEMENT OF GLOWING EMBERS AND LAVA ROCK Placement of the g...

Страница 13: ... present to lowest setting If applicable Turn off all electric power to the heater Note For easy access to valve for lighting pilot remove branch log and middle log from burner assembly before lighting 1 STOP Read the safety information label 2 Make sure the manual shutoff valve is fully open 3 This gas log set is equipped with an ignition device piezo which lights the pilot If piezo ignitor does ...

Страница 14: ... clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information If you do not smell gas go to the next step 5 Find pilot the pilot is attached to rear of burner 6 Turn gas knob counterclockwise to IGN 7 Depress and turn gas control knob counterclockwise to PILOT A spark is produced when gas control knob is turned between IGN and PILOT Repeate...

Страница 15: ... the ODS pilot will not stay lit after several tries push and turn the gas control knob clockwise to OFF and wait 15 seconds Repeat steps 6 through 9 10 Push in control knob and turn to desired setting 1 2 3 The control knob must be set at either the low or high position and the control knob will pop out when positioned correctly Do not set the control knob at a position between pilot 1 2 3 TO TUR...

Страница 16: ... Figure 17 If pilot flame pattern is incorrect as shown in Figure 17 See Troubleshooting page 19 Cleaning and Maintenance Pilot Oxygen Depletion Sensor Pilot Figure 18 When the pilot has a large yellow tip flame clean the Oxygen Depletion Sensor as follows 1 Clean the ODS pilot by loosening nut B from the pilot tubing When this procedure is required grasp nut A with an open end wrench 2 Blow air p...

Страница 17: ...tems discussed below Inspect and clean burner air intake hole Remove lint or particles with vacuum or brush Failure to keep air intake hole clean will result in sooting and poor combustion Inspect and clean all burner ports Inspect ODS pilot for operation and accumulation of lint at air intake holes Verify flame pattern and log placement for proper operation Verify smooth and responsive ignition o...

Страница 18: ...After 30 seconds to 1 minute time period you can release the gas control knob and the pilot will stay ON Allow your pilot flame to operate an additional one 1 to two 2 minutes before you turn the gas control knob from the PILOT position to the ON position This time period allows the millivolts electrical current to buildup to a sufficient level allowing the gas control to operate properly Millivol...

Страница 19: ...ame goes out when control knob is released a Control knob not fully pressed in Press in control knob fully b Control knob not pressed in long enough After ODS pilot lights keep control knob pressed in 30 seconds c Manual Shutoff valve not fully open Fully open manual shutoff valve d Thermocouple connection loose at control valve Hand tighten until snug then tighten 1 4 turn more e Pilot flame not ...

Страница 20: ...G NS 11292 TUBING VALVE TO PILOT LPG NS 14039 TUBING VALVE TO PILOT REGULATOR NAT Index Part No Number Description Attention When ordering parts it is very important that part number and description of part coincide USE ONLY MANUFACTURER S REPLACEMENT PARTS USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH NS 14041 TUBING PILOT REGULATOR TO PILOT NAT NS 11291 TUBING VALVE TO BURNER NS R 5668 IGNI...

Страница 21: ...hen determine the Part Number not the Index Number and the Description of each part from the following appropriate illustration and list Be sure to give all this information Applaince Model Number Part Description Appliance Serial Number Part Number Type of Gas Propane or Natural Do not order bolts screws washers or nuts They are standard hardware items and can be purchased at any local hardware s...

Страница 22: ...Page 22 15994 2 0504 SERVICE NOTES ...

Страница 23: ...Page 23 15994 2 0504 SERVICE NOTES ...

Страница 24: ...4 Empire Comfort Systems Inc Nine Eighteen Freeburg Ave Belleville Illinois 62220 2623 PH 1 618 233 7420 PH 1 800 851 3153 FAX 1 618 233 7097 FAX 1 800 443 8648 E MAIL info empirecomfort com WEB SITE www empirecomfort com ...