background image

25233-0-0109

Page 12

cAuTION: ALL wIrINg ShOuLD Be DONe By A QuALIFIeD eLecTrIcIAN AND ShALL Be IN cOMpLIANce 

wITh ALL LOcAL, cITy AND STATe BuILDINg cODeS. BeFOre MAKINg The eLecTrIcAL cONNecTION, 

MAKe Sure ThAT MAIN pOwer SuppLy IS DIScONNecTeD. The AppLIANce, wheN INSTALLeD, MuST Be 

eLecTrIcALLy grOuNDeD IN AccOrDANce wITh LOcAL cODeS Or, IN The ABSeNce OF LOcAL cODeS, 

wITh The NATIONAL eLecTrIcAL cODe ANSI/NFpA 70 (LATeST eDITION)

a factory installed junction box is located on the lower right 

hand side of the firebox. Wiring must be fed to the junction 

box and attached to the receptacle that is provided. Remove the 

knockout in the installed junction box to accept wiring into the 

junction box. install a UL listed cable clamp (not supplied) in the 

knockout hole. Leave approximately 6" of wire in the junction 

box for connection.
attach black wire to one side of the receptacle and white wire to 

opposite side of receptacle. the ground wire should be attached 

to the green (neutral) screw.
install the receptacle into the junction box. attach cover plate.

Keep the control compartment, logs and burner area surrounding the 

logs clean by vacuuming or brushing area at least twice a year.
tHE LogS can gEt VERY Hot – HanDLE onLY WHEn 

cooL.
always turn off gas to the pilot before cleaning. For relighting, 

refer to lighting instructions located on the log set.

Never obstruct the flow of the combustion and ventilation air. Keep 

the front of the firebox clear of all obstacles and materials.

Screens must be closed during operation.

Figure 20

JUnction BoX WiRing inStaLLation inStRUctionS

MaintEnancE

INDex 

NO.

pArT NuMBer.

DeScrIpTION

VFS32FB2DF

VFS32FB3DF

VFS32FB2eF

VFS32FB3eF

1

17247

17247

17247

17247

toP StanDoFF

2

10554

10554

10554

10554

FRaMing BRacKEt

3

17162

17162

17162

17162

JUnction BoX aSSEMBLY

4

R3492

R3492

R3492

R3492

Receptacle

5

R3491

R3491

R3491

R3491

coVER, JUnction BoX

6

19945

19945

19945

19945

BRacKEt, toP BRicK REtainER 

7

R8667

R8667

R9422

R9422

BRicK PanEL RigHt

8

BRicK PanEL BacK

9

BRicK PanEL LEFt

10

20020

20020

20020

20020

HooD

11

R7051

R7051

R7051

R7051

RoD, ScREEn

12

R8213

R8213

R8213

R8213

ScREEn cURtain

13

19401

19401

19401

19401

BRacKEt, BottoM BRicK REtainER

14

R9292

R9292

R9292

R9292

HEaRtH LEDgE, RigHt

15

R9293

R9293

R9293

R9293

HEaRtH LEDgE, LEFt

16

R9294

R9294

R9294

R9294

HEaRtH LEDgE, cEntER

17

23004

23004

23004

23004

REtainER, HEaRtH LEDgE

PaRtS LiSt

Содержание FS36FB3EF-3

Страница 1: ...on consult a qualified installer service agency or the gas supplier Carefully review the instructions supplied with the decora tive type unvented room heater for the minimum fireplace size requirement DO NOT INSTALL a vent free log set IN THIS FIREBOX UNLESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS REQUIRED FOR THE INSTALLATION GAS FIRED ANSI Z21 91 Ventless Fireplace Enclosures for Gas Fired Dec...

Страница 2: ...ebox Installation Instructions 5 7 Installing Hood 7 8 Gas Line Connection 8 Optional Single Speed Blower Installation Instructions 9 11 Junction Box Wiring Installation Instructions 12 Maintenance 12 Parts List 12 13 Parts View 14 How to Order Repair Parts 14 Accessories 15 16 TABLE OF CONTENTS ...

Страница 3: ...f such component part or accessory Any such action may create a possible fire hazard Consult your local building codes Firebox Screen The firebox screen must be in place when the firebox is operating Instructions to Installer 1 Installer must leave instruction manual with owner after installation 2 Installer must have owner fill out and mail warranty card supplied with firebox 3 Installer should s...

Страница 4: ...learance The minimum clearance between the front legs of the grate and front edge of the firebox is 2 Leave at least 36 clearance from the front of the firebox CLEARANCES 45 6 3 MAX PERPENDICULAR SIDE WALL FRONT FACE SIDE FIREBOX TOP VIEW COMBUSTIBLE MATERIALS ALLOWED IN SHADED AREAS MANTEL STANDARD HOOD 13 10 12 MAX 42 MIN CEILING TO TOP OF HOOD 11 1 2 MIN FIREBOX FACE 84 MIN CEILING TO FLOOR CEI...

Страница 5: ...on all four perimeter edges on the bottom of the unit Example Four 4 concrete masonry blocks If the firebox is installed directly on carpeting tile or other combustible material other than wood flooring it should be installed on a metal or wood panel extending the full width and depth of the unit At this point you should have decided what components to include in your installation and where the fi...

Страница 6: ...ed SELECT REFERENCE LETTER FLUSH VFS32 VFS36 VFS42 A 41 1 8 41 1 8 41 1 8 B 34 1 2 39 1 2 43 1 2 C 23 7 16 23 7 16 23 7 16 D 26 3 8 31 3 8 35 3 8 E 38 1 2 38 1 2 38 1 2 F 31 36 40 G 31 3 4 31 3 4 31 3 4 H 2 1 8 2 1 8 2 1 8 I 34 34 34 J 4 1 4 4 1 4 4 1 4 K 7 5 8 7 5 8 7 5 8 L 36 1 2 39 1 16 41 1 16 M 73 1 16 78 1 16 82 1 16 ...

Страница 7: ...hed with each firebox or optional hood MUST be installed before the firebox is used Failure to do so may create a possible fire hazard The hood is located inside the firebox on flush face units If brass stainless steel or hammered pewter hoods are desired they can be purchased as an option Attachment is the same as the standard black hood Flush Face Models 1 On flush face models loosen the two scr...

Страница 8: ... pressure to a maximum of 14 w c This is in addition to the regulator fitted to the log set WARNING CONNECTION DIRECTLY TO AN UNREGULATED L P TANK CAN CAUSE EXPLOSION Install only a ANSI Z21 11 2 vent free log set into this firebox Figure 10 Extended Hoods If your non combustible facing material is over 1 in thickness that will be used to finish this firebox an extended hood is available that will...

Страница 9: ...tion of the wiring be performed by a qualified electrician See Figure 12 1 If installed turn OFF gas supply to firebox gas log 2 If applicable turn OFF electric supply to firebox CAUTION ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL CITY AND STATE BUILDING CODES BEFORE MAKING THE ELECTRI CAL CONNECTION MAKE SURE THAT MAIN POWER SUPPLY IS DISCONNECTE...

Страница 10: ...minal Attach this terminal to the open terminal on the blower power cord See Figure 19 Connection B 10 Route the wires away from moving parts of the blower as sembly and retain wires together near the blower motor using the plastic purse clip provided 11 To complete the installation plug the power cord into the junction box receptacle at the right rear corner of the firebox outer wrap See Figure 1...

Страница 11: ... a dirty blower wheel Remove fan and clean blower wheels Warning Unplugging of blower accessory will not stop the heater from cycling To turn off gas to the heater millivolt model push in gas control knob slightly and turn clockwise to OFF Do not force To turn off gas on direct ignition model turn gas line valve to OFF 1 FBB5 BLOWER ASSEMBLY COMPLETE 2 R9901 FAN CONTROL SWITCH 1 2 A B 110 VOLT AC ...

Страница 12: ...urner area surrounding the logs clean by vacuuming or brushing area at least twice a year THE LOGS CAN GET VERY HOT HANDLE ONLY WHEN COOL Always turn off gas to the pilot before cleaning For relighting refer to lighting instructions located on the log set Never obstruct the flow of the combustion and ventilation air Keep the front of the firebox clear of all obstacles and materials Screens must be...

Страница 13: ...9293 HEARTH LEDGE LEFT 16 R9295 R9295 R9295 R9295 HEARTH LEDGE CENTER 17 23004 23004 23004 23004 RETAINER HEARTH LEDGE ITEM VFS42FB2DF VFS42FB3DF VFS42FB2EF VFS42FB3EF DESCRIPTION 1 17247 17247 17247 17247 TOP STANDOFF 2 10554 10554 10554 10554 FRAMING BRACKET 3 17162 17162 17162 17162 JUNCTION BOX ASSEMBLY 4 R3492 R3492 R3492 R3492 Receptacle 5 R3491 R3491 R3491 R3491 COVER JUNCTION BOX 6 19945 1...

Страница 14: ...m the name plate on your equipment Then determine the Part Number not the Index Number and the Description of each part from the following appropriate illustration and list Be sure to give all this information Firebox Model Number Part Description Firebox Serial Number Part Number Do not order bolts screws washers or nuts They are standard hardware items and can be purchased at any local hardware ...

Страница 15: ...use with FBB5 blower SCV 1 Frame Kits Standard 3 Piece Frame Kits Black Brass Stainless Steel or Hammered Pewter Extruded Aluminum Frame Kits Black Brass Stainless Steel or Hammered Pewter Contact dealer for all available optional frame kits Standard Hood Brass hood BR Stainless Steel SS Hammered Pewter HP Contact dealer for all available optional hood accessories ACCESSORIES ...

Страница 16: ...nd Stainless Steel finishes Contact dealer for all available optional frame kit accessories Decorative Frame Kits Available as optional kits in Black Brass Hammered Pew ter and Stainless Steel finishes Contact dealer for all available optional decorative door kit accessories ACCESSORIES continued EMPIRE EMPIRE Comfort Systems Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you h...

Отзывы: