![White Mountain Hearth DVLL27FP92(N,P)-1 Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/white-mountain-hearth/dvll27fp92-n-p-1/dvll27fp92-n-p-1_installation-instructions-and-owners-manual_976167005.webp)
33740-7-0515
Page 5
SpECIFICATIONS
DVTL27Fp92N
(NAT)
DVTL27Fp92p
(Lp)
Input BTU/Hr Maximum
36,000
36,000
Input BTU/Hr Minimum
11,500
11,000
KWH (Maximum)
10.55
10.55
KWH (Minimum)
3.37
3.22
Orifice (Front)
1.90mm
#57
Orifice (Back)
#43
1.45mm
Air Shutter Opening (Front)
1/4”
Full Open
Air Shutter Opening (Back)
3/16”
Full Open
Height without standoff
47-3/8”
47-3/8”
Width
37-3/8”
37-3/8”
Depth
24-3/8”
24-3/8”
Gas Inlet Shutoff Valve (pipe)
1/2 NPT
1/2 NPT
NOTE:
Air shutter settings are factory minimum settings. Some venting configurations may require minor air shutter adjustments for
optimum performance.
GAS SUppLY pRESSURES
GAS TYpE
MAXIMUM
MINIMUM
MANIFOLD
NAT
14.0”
4.5”
3.5”
LP
14.0”
10.8”
10.0”