White Mountain Hearth BVD34FP30 Скачать руководство пользователя страница 4

Page 4

19400-3-0406

Some people cannot smell well. Some people cannot smell the 

odor of the chemical put into the gas. You must find out if 

you can smell the odorant in propane.

 Smoking can decrease 

your ability to smell. Being around an odor for a time can affect 

your sensitivity or ability to detect that odor. Sometimes other 

odors in the area mask the gas odor. People may not smell the 

gas odor or their minds are on something else. Thinking about 

smelling a gas odor can make it easier to smell.

The odorant in LP-Gas is colorless, and it can fade under 

some circumstances.

 For example, if there is an underground 

leak, the movement of the gas through soil can filter the odorant. 

Odorants in LP-Gas also are subject to oxidation. This fading 

them point by point with the members of your household. 

Someday when there may not be a minute to lose, everyone’s 

safety will depend on knowing exactly what to do. If, after 

reading the following information, you feel you still need 

more information, please contact your gas supplier.

Propane (LP-Gas) is a flammable gas which can cause fires 

and  explosions.  In  its  natural  state,  propane  is  odorless 

and colorless. You may not know all the following safety  

precautions which can protect both you and your family 

from  an  accident.  Read  them  carefully  now,  then  review 

can occur if there is rust inside the storage tank or in iron gas 

pipes.
The odorant in escaped gas can adsorb or absorb onto or into 

walls, masonry and other materials and fabrics in a room. That 

will take some of the odorant out of the gas, reducing its odor 

intensity.
LP-Gas may stratify in a closed area, and the odor intensity 

could vary at different levels. Since it is heavier than air, there 

may be more odor at lower levels. Always be sensitive to the 

slightest gas odor. If you detect any odor, treat it as a serious 

leak. Immediately go into action as instructed earlier.

• 

Learn to recognize the odor of LP-Gas.

 Your local LP-Gas 

Dealer can give you a “Scratch and Sniff” pamphlet. Use it 

to find out what the propane odor smells like. If you suspect 

that your LP-Gas has a weak or abnormal odor, call your 

LP-Gas Dealer.

•  If you are not qualified, do not light pilot lights, perform 

service, or make adjustments to appliances on the LP-Gas 

system.  If  you  are  qualified,  consciously  think  about  the 

odor of LP-Gas prior to and while lighting pilot lights or 

performing service or making adjustments.

•  Sometimes a basement or a closed-up house has a musty 

smell that can cover up the LP-Gas odor. Do not try to light 

pilot lights, perform service, or make adjustments in an area 

where the conditions are such that you may not detect the 

odor if there has been a leak of LP-Gas.

•  Odor fade, due to oxidation by rust or adsorption on walls 

of new cylinders and tanks, is possible. Therefore, people 

should be particularly alert and careful when new tanks or 

cylinders are placed in service. Odor fade can occur in new 

tanks, or reinstalled old tanks, if they are filled and allowed 

to set too long before refilling. Cylinders and tanks which 

have been out of service for a time may develop internal rust 

which will cause odor fade. If such conditions are suspected 

to exist, a periodic sniff test of the gas is advisable. 

If you 

have any question about the gas odor, call your LP-Gas 

dealer. A periodic sniff test of the LP-Gas is a good safety 

measure under any condition.

•  If, at any time, you do not smell the LP-Gas odorant and you 

think you should, assume you have a leak. Then take the same 

immediate action recommended above for the occasion when 

you do detect the odorized LP-Gas.

•  If you experience a complete “gas out,” (the container is 

under no vapor pressure), turn the tank valve off immediately. 

If the container valve is left on, the container may draw in 

some air through openings such as pilot light orifices. If this 

occurs, some new internal rusting could occur. If the valve is 

left open, then treat the container as a new tank. Always be 

sure your container is under vapor pressure by turning it off 

at the container before it goes completely empty or having 

it refilled before it is completely empty.

•  Do not operate electric switches, light matches, use your 

phone. Do not do anything that could ignite the gas.

•   Get everyone out of the building, vehicle, trailer, or area. 

Do that IMMEDIATELY.

•   Close all gas tank or cylinder supply valves.

•   LP-Gas is heavier than air and may settle in low areas such 

as basements. When you have reason to suspect a gas leak, 

keep out of basements and other low areas. Stay out until 

firefighters declare them to be safe.

•   Use your neighbor’s phone and call a trained LP-Gas service 

person and the fire department. Even though you may not 

continue to smell gas, do not turn on the gas again. Do not 

re-enter the building, vehicle, trailer, or area.

• 

  Finally,

 let the service man and firefighters check for escaped 

gas. Have them air out the area before you return. Properly 

trained LP-Gas service people should repair the leak, then 

check and relight the gas appliance for you.

SOME POINTS TO REMEMBER

NO ODOR DETECTED - ODOR FADE

LP-GAS WARNING ODOR

If a gas leak happens, you should be able to smell the gas because of the odorant put in the LP-Gas. 

That’s your signal to go into immediate action!

SAFETY INFORMATION FOR USERS OF LP GAS

Содержание BVD34FP30

Страница 1: ...e with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used The Keystone B Vent Zero Clearance Gas Fireplace WARNING If the information in this manual is not followedexactly afireorexplosionmayresultcausing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquid...

Страница 2: ...ting 20 Standing Pilot Propane LP Gas Conversion 21 22 Direct Ignition Wiring Diagram 23 Optional Remote Control 120V Direct Ignition 23 Direct Ignition Lighting Instructions 24 Direct Ignition Troubleshooting 25 Direct Ignition Propane LP Gas Conversion 25 26 Maintenance and Service 27 BVD34 and BVD36 Parts List 28 BVD34 and BVD36 Parts View 29 BVP42 Parts List 30 BVP42 Parts View 31 FBB4 Optiona...

Страница 3: ...he appliance should be located out of traffic and away from furniture and draperies Any part removed for servicing the appliance must be replaced prior to operating the appliance Work should be done by a qualified service person Keep burner and control compartment clean Vent cap is hot while fireplace is in operation Installation and repair should be done by a QUALIFIED SERVICE PERSON The appliance s...

Страница 4: ...ry to light pilot lights perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls of new cylinders and tanks is possible Therefore people should be particularly alert and careful when new tanks or cylinders are placed in service Odor fade can occur in ne...

Страница 5: ...serious injuryordeathfromfire burns explosions orcarbonmonoxide poisoning Any alteration of the original design installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the person and company making the change Important All correspondence should refer to complete Model Number Serial Number and type of gas High Altitude When...

Страница 6: ... BVD34FP BVD36FP BVP42FP Input Btu hr Maximum 21 000 25 000 30 000 KWH Maximum 6 2 7 3 8 8 B Vent Size 4 Diameter 6 Diameter 6 Diameter NAT Standard Orifice 44 086 P 252 42 0935 P 286 37 104 P 213 Air Shutter Opening 1 8 3 2mm 1 8 3 2mm 1 8 3 2mm LP Conversion Kit Required Orifice 1 35mm P 289 1 45 mm P 208 1 65mm P 250 Air Shutter Opening 5 16 7 9mm 5 16 7 9mm Full Open Height without standoff 32 3...

Страница 7: ...namentation of any type should be placed on or attached to the fireplace The flow of heat can ignite combustibles Clearance to Combustibles Back 0 0 mm Side 0 0 mm Floor 0 0 mm Top Stand off 0 0 mm Top Framing Edge 1 25mm 12 TOP EDGE OF FIREPLACE 12 305mm 10 254mm MANTEL COMBUSTIBLE TRIM AND MANTELS ALLOWED IN SHADED AREA 1 4 6 35mm 3 4 5 6 8 10 3 4 3 4 1 2 1 4 3 3 3 4 4 6 8 1 2 SEE MANTLE CHART FOR...

Страница 8: ...fromsupplypipingsystemduringanypressuretestingofthatsystem at test pressures in excess of 1 2 psig 3 5kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5kPa Attention If one of the procedures results in pressures in excess...

Страница 9: ...t in pressure regulator in the gas valve Natural gas models will have a manifold pressure of approximately 3 5 w c 871kPa at the valve outlet with the inlet pressure to the valve from a minimum of 4 5 w c 1 120kPa for the purpose of input adjustment to a maximum of 14 0 w c 3 484kPa Propane gas models will have a manifold pressure approximately 10 0 w c 2 49kPa at the valve outlet with the inlet p...

Страница 10: ...taken by utilizing outside air for combustion It is strongly recommended that it be installed Installation of the fresh air kit should be performed at the framing stage of the fireplace installation The fresh air kit installs on the left side of the fireplace To install the BVA1 fresh air kit refer to the installation instructions provided with the kit Note The outside air kit can terminate at any l...

Страница 11: ...ces around air openings into the combustion chamber Caution If the joints between the finished wall and the fireplace surround top and sides are sealed a 300 F minimum sealant material must be used These joints are not required to be sealed Only non combustible material using 300 F minimum adhesive if needed can be applied as facing to the fireplace surround Combustible Surround Installation Figure 1...

Страница 12: ...are exposed to the elements for corrosion These will appear as rust spots or streaks and in extreme cases holes These components should immediately be replaced 2 Remove the cap and shine a flashlight down the vent Remove any bird nests or other foreign material 3 Check for evidence of excessive condensate such as water droplets forming in the inner liner and subsequently dripping out at joints Cond...

Страница 13: ...ith Elbows Figure 15 Vent supports are per vent manufacturer s specifications Minimum clearances are per vent manufacturer s specifications 40 ft Max 11 ft Min 90 degree or 45 degree Elbows Straight Section 2 ft Minimum off top of unit before using elbows Vent supports per manufacturers vent specifications Horizontal vent to maintain a 1 4 rise per ft Min 11 ft Min Maximum horizontal distance is 5...

Страница 14: ... be placed on the fireplace floor EMBER MATERIAL PLACEMENT ON BURNER 6 After all logs are positioned properly apply Rockwool ember material to the front burner port area To apply carefully separate the ember material into small amounts no larger than dime size pieces Fluffed up pieces one layer thick on top of the burner generally works best and will provide the best ember glow Do not place ember ma...

Страница 15: ...operly and firmly positioned in the fireplace Please refer to Figure 18 Figure 19 and Figure 20 and corresponding WARNING when completing the following log placement steps 1 Place bottom log onto main burner Align holes on bottom log with 4 locator pins on burner 2 Place rear log on rear log shelf Place rear log so that the locator holes align with the 2 locator tabs in the log support shelf 3 Place...

Страница 16: ...0 seconds to 1 minute time period you can release the gas control knob and the pilot will stay ON Allow your pilot flame to operateanadditionalone 1 totwo 2 minutesbeforeyouturnthe gascontrolknobfromthePILOTpositiontotheONposition This time period allows the millivolts electrical current to build up to a sufficient level allowing the gas control to operate properly 1 Follow the SAFETY and LIGHTING I...

Страница 17: ...ce disconnect both of the insulated wall switch wire terminal leads from the gas valve and discard the wall switch wire Connect the two wire leads from the FREC receiver to the TH and TH TP terminals on the gas valve Next attach the short power cord to the remote receiver then plug the power cord into the junction box receptacle located at the bottom right side of the fireplace The remote receiver ...

Страница 18: ...EUR FACULTATIVE CONTROLE E DISTANCE WALL SWITCH INTERRUPTEUR MURAL OPTIONAL THERMOSTAT FACULATIVE THERMOSTAT GAS VALVE VALVE DE GAZ WALL SWITCH REMOTE CONTROL RECEIVER THERMOSTAT CONTROLE E DISTANCE DU RECEPTEUR H N PILOT VEILLEUSE LIMIT SWITCH V E N T P I L O T IN STANDING PILOT WIRING DIAGRAM ...

Страница 19: ...R YOUR SAFETY READ BEFORE LIGHTING WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE TO TURN OFF GAS TO FIREPLACE 1 Set wall switch or remote to OFF 2 Turn off all electric power to the appliance if service is to be performed if applicable 3 Open bottom louver assembly or open valve access door 4 Push in g...

Страница 20: ...pile adjust the pilot flame Be sure the wire connections from the thermopile at the gas valve terminals are tight and the thermopile is fully inserted into the pilot bracket Check the thermopile with a millivolt meter Take the reading at TH TP TP terminals of the gas valve The meter should read 350 millivolts minimum while holding the valve knob depressed in the PILOT position with the pilot lit an...

Страница 21: ...Description Kit No 19160 Kit No 19161 Kit No 19162 Quantity Supplied Fireplace BVD34FP3 SERIES BVD36FP3 SERIES BVP42FP3 SERIES Pilot Orifice 35 R 7658 35 R 7658 35 R 7658 1 Main Burner Orifice P 289 1 35mm P 208 1 45mm P 250 1 65mm 1 Dexen 10 w c Regulator R 7548 R 7548 R 7548 1 Gas Conversion Label 2139 2139 2139 1 Gas input for B Vent fireplace converted to Liquefied Petroleum Gas BVD34FP3 SERIES 21...

Страница 22: ...n on the gas supply Turn on the electrical supply to the appliance 24 Immediately test all gas line connections and the control valve for gas leaks using a soap and water solution or gas detection for solution Bubbles indicate a leak that MUST be corrected Do not use an open flame to check for gas leaks 25 Using a ball point pen fill out the conversion label that is supplied with the conversion kit ...

Страница 23: ...n burner flame failed 4 times during a single heating cycle 4 Flashes Interrupt power for 5 seconds to reset control Steady Flash Flame detected out of sequence Electric 120 volt Operated Remote Control FREC 1 Disconnect 3 prong power cord from receptacle 2 Remove wire from 120 VAC hot terminal on control module 3 Connect female terminal from receiver onto 120 VAC hot terminal on control module 4 C...

Страница 24: ...PERSONAL INJURY OR LOSS OF LIFE TO TURN OFF GAS TO APPLIANCE 1 STOP Read the safety information above 2 Turn off all electric power to the appliance 3 Open bottom louver assembly or open the valve access door 4 Turn gas line valve to OFF 5 Close bottom louver assembly or close valve access door 1 STOP Read the safety information above 2 Turn off all electric power to the appliance 3 This appliance...

Страница 25: ...or for shorts Replace spark electrode assembly c Refer to installation instructions troubleshooting guide for issues such as venting Repair as required The conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and in accordance with the requirements of the CSA B149 2 installation code Canada and with the requirements of the National F...

Страница 26: ...lacement pages 14 and 15 to place logs onto burner assembly 18 Loosen screw and attach a manometer or pressure gauge to the outlet pressure tap of the control valve 19 Turn on the gas supply Turn on the electrical supply to the appliance Check for gas leaks using soap and water solution or leak detection solution Bubbles indicate a leak that MUST be corrected Do not use an open flame to test for ga...

Страница 27: ...plicable Ifitappearsabnormal call a service person Check Vent System The appliance and venting system should be inspected before initial use and at least annually by a qualified service person Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the air flow Glass Cleaning Optional Kits It will be necessary to clean the glass periodically During start up c...

Страница 28: ... TUBING ASSEMBLY 22 R2423 R2423 R2423 R2423 MALE ADAPTOR 23 R7590 R7590 R7590 R7590 SPARK IGNITOR DIRECT IGNITION 24 17315 17315 17315 17315 SPARK IGNITOR MOUNTING PLATE DIRECT IGNITION 25 R8132 R8132 R8132 R8132 PILOT MILLIVOLT 25a R5710 R5710 R5710 R5710 THERMOPILE 26 R7617 R7617 R7617 R7617 PILOT GASKET 27 19382 19382 19418 19418 BURNER BASE ASSEMBLY 28a 19381 19381 19381 19381 VALVE BRACKET MI...

Страница 29: ... 12 13 14 15 16 17 18 19 20 21 22 23 24 26 27 28b 25 19 17 18 26 27 28a 21 20 15 29a 30 31 32 33 35a 34 35b 36 37 38 39 16 22 29b 40 41 DIRECT IGNITION BURNER ASSEMBLY MILLIVOLT BURNER ASSEMBLY 5 PIECE LOG ASSEMBLY 43 44 42 25a BVD34 BVD36 PARTS VIEW ...

Страница 30: ...R7590 R7590 SPARK IGNITOR DIRECT IGNITION 24 R7612 R7612 PILOT MILLIVOLT 24a R5710 R5710 THERMOPILE 25 19545 19545 SPARK IGNITOR SHIELD DIRECT IGNITION 26 R7617 R7617 PILOT GASKET MILLIVOLT 26a M173 M173 PILOT GASKET DIRECT IGNITION 27 19455 19455 BURNER BASE ASSEMBLY 28a 19381 19381 VALVE BRACKET MILLIVOLT 28b 20207 20207 VALVE BRACKET DIRECT IGNITION 29a R8380 R8380 VALVE MILLIVOLT GAS 29b R7733...

Страница 31: ...0 11 12 13 14 21 22 29b 28a 29a 30 21 20a 31 32 33 34 35a 35b 36 37 38 39 DIRECT IGNITION BURNER ASSEMBLY MILLIVOLT BURNER ASSEMBLY 3 PIECE LOG ASSEMBLY 28b 16 19 17 18 27 20b 15 26 24 22 25 16 19 17 18 27 15 26a 23 40 41 42 24a BVP42 PARTS VIEW ...

Страница 32: ...assembly with center screw on fireplace back and push blower assembly against fireplace back The magnets on the back and bottom of blower assembly will sufficiently hold blower assembly in place 6 Position speed control box to the right of gas valve Attach speed control box to bottom of fireplace The magnets on bottom of speed control box will sufficiently hold speed control box in place 7 With base flu...

Страница 33: ...C JUNCTION BOX WHITE SPEED CONTROL FAN SWITCH GROUND BLACK FAN 1 FBB4 BLOWER ASSEMBLY COMPLETE 2 R7649 FAN CONTROL 3 R4192 SPEED CONTROL KNOB 4 R4186 SPEED CONTROL Figure 26 Figure 27 FBB4 OPTIONAL VARIABLE SPEED BLOWER INSTALLATION ...

Страница 34: ...he ground wire should be attached to the green ground screw Install the receptacle into the junction box Attach cover plate Figure 28 STANDARD MILLIVOLT VALVE MODELS 120V DIRECT IGNITION VALVE MODELS 1 To wire Junction Box Receptacle remove the tab on the side of the receptacle hot side to split receptacle This will be required to separate blower and valve circuits 2 Power for switched and live si...

Страница 35: ...nce the appearance of your fireplace imitating the look of authentic masonry AGED BRICK BVD2SA BVD34FP BVD36SA BVD36FP BVP3SA BVP42FP Fresh Air Kit Installs to side of fireplace to provide fresh air make up when operating fireplace optional Note Requires standard 4 diameter flexible or hard pipe connector not included with kit BVA1 Optional Bifold Glass Door Accessory Includes bifold tempered glass do...

Страница 36: ...lain Rectangle Decorative Frame Arch with hinges Decorative Door Leaf Arch Decorative Door Mission Arch Decorative Door Plain Arch Outside Frame Kits STD Louvers 45 Deg Bottom Trim Frame Decorative Frame Arch without hinges only Black Please contact your nearest dealer distributor for more information on all available optional decorative accessories Page 36 19400 0 1005 DECORATIVE ACCESSORIES ...

Страница 37: ...ine the Part Number not the Index Number and the Description of each part from the following appropriate illustration and list Be sure to give all this information Fireplace Number Part Description Fireplace Serial Number Part Number Type of Gas Propane or Natural Do not order bolts screws washers or nuts They are standard hardware items and can be purchased at any local hardware store Shipments c...

Страница 38: ...Page 38 19400 3 0406 SERVICE NOTES ...

Страница 39: ...Page 39 19400 3 0406 SERVICE NOTES ...

Страница 40: ...Page 40 19400 3 0406 Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH 618 233 7420 or 800 851 3153 FAX 618 233 7097 or 800 443 8648 info empirecomfort com www empirecomfort com ...

Отзывы: