Manual Version 1.3.1
Manual Part# 18200-LM-0038
* In the case where the tool varies the air pressure to a shuttle-operated pump, there is no need to connect the
system on signal to an additional air valve.
** See Pump manual for wire leak detection.
6 PC to CPT-1 Communication:
6.1 Ethernet Connection:
An Ethernet connection is only needed for using the CPT-1 setup software. After the controller has been setup, the
settings can be saved and disconnected to be run as a standalone unit. The CPT-1 uses two industry standard
Ethernet connections TCP/IP and UDP/IP the controller will automatically respond in the format to which it is
connected. When connecting the CPT-1 to a local network, it will look to the server to assign it an IP address. This
is supported on both DHCP and BOOT-P server protocols.
6.2 RS-232 Connection:
An RS-232 connection can be created through the 9-pin serial port on the box. When opening the software, the
RS-232 port will show as a COM port and will give two baud rate options, 19200 and 115000. The default baud
rate is 115000, but the slower 19200 baud rate can be selected by placing a jumper on the connection labeled
19.2 on the upper left side of the control box.
7 Software Setup:
7.1 Installation:
Download the CPT-1 setup software at
wkfluidhandling.com/cpt-1
.
Run the installers by double-clicking on the
installer executable (.exe) file, and follow the on screen prompts. Software requires Windows XP or newer version
of Windows.
7.2 Using the Software:
1. Open “WK Cycle Rate Translator.exe”.
2. Wait for the connections window to show. If you have a CPT-1 connected to the computer via RS-232 or to
the network via Ethernet, it will show in the connections window. See Figure 5 for an image of the
connections window.
CPT-1 Connected via Ethernet
CPT-1 Connected via RS-232
Figure 5: Connections Window