background image

TABLE OF CONTENTS

Introduction

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Before You Start

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Receiving and Inspecting the Unit

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Quick Reference Guide

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Controller Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

Unit Specifications   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

Preparing the Wine Cellar

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Pre-Installation

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Testing the Unit prior to Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

Installation Guide

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Preparing the Installation Location

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Preparing the Unit for Installation

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Installing the Unit through the Wall

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Condensation Drain Line

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Liquid Measuring Thermostat System

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

System Operation

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Controller

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Functions

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Alarm Codes

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

CPSM (Customer Preference Selection Mode)

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Wiring Schematic

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Troubleshooting Guide

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Maintenance Schedule

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Technical Assistance

 & 

Accessories

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Installation Terms & Conditions

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Содержание SC PRO 2000

Страница 1: ...SC PRO SERIES OWNER S MANUAL SC PRO 2000 SC PRO 3000 SC PRO 4000...

Страница 2: ...not responsible for printing or clerical errors WhisperKOOL reserves the right to make corrections or improvements to the information provided and to the related hardware at any time without notice V...

Страница 3: ...stallation Guide 11 Preparing the Installation Location 11 Preparing the Unit for Installation 12 Installing the Unit through the Wall 13 Condensation Drain Line 14 Liquid Measuring Thermostat System...

Страница 4: ...the WhisperKOOL Cooling Unit The WhisperKOOL cooling unit is a specialized refrigeration unit designed for one purpose only to maintain the optimal temperature and humidity levels conducive to the pr...

Страница 5: ...on the right side of the unit to select the inlet you would like to use 5 The unit is designed to gently cool down the temperature of the cellar over time by cycling cooler air throughout Test the uni...

Страница 6: ...manual 1 Bypass plug 1 Liquid measuring thermostat bottle probe Accessory kit 2 1 Power cord 8 feet 1 Piece of mounting bracket insulation foam 6feet 11 1 standard screws 7 1 2 Phillips pan head scre...

Страница 7: ...www whisperkool com Page 5 SC PRO Series QUICK REFERENCE GUIDE Front Side View Rear Side View Controller Bottle probe Probe input Control panel see page 10 for details Drain port Rear power inlet...

Страница 8: ...tubing Installation Through the wall Thermostat Advanced digital controller liquid temperature measuring bottle probe Temp Delta Can maintain a 55 F cellar temperature with up to 85 F condenser air i...

Страница 9: ...er vapor creates its own pressure separate from the ambient air pressure and will intrude into colder drier areas A vapor barrier is REQUIRED in order to prevent the intrusion of water vapor and maint...

Страница 10: ...ipate or absorb heat from the space The system will operate more efficiently with a greater amount of air to exchange NOTE Do not attempt to mount the unit in a wall recess or attempt to camouflage or...

Страница 11: ...r amount of heat is generated on the exhaust side of the unit Adequate ventilation is required in order to dissipate heat away from the unit If ventilation is inadequate the exhaust will heat the area...

Страница 12: ...spikes can damage sensitive electrical equipment WhisperKOOL recommends plugging the unit into a surge protector or power conditioner in order to protect your system As outlined in our terms and cond...

Страница 13: ...studs themselves Make the second horizontal cut from stud to stud on the line 16 inches below the first cut Once the horizontal lines have been cut make vertical cuts using the inside edge of the stud...

Страница 14: ...g the distance between the pieces of tape on the top and bottom edges of the mounting bracket then cut remove paper backing and secure Do the same on the opposite side of the bracket Discard any exces...

Страница 15: ...to the wall Secure the flange to the wall through the pre drilled holes The screws should penetrate the studs as well as the upper and lower supports to provide adequate support for the WhisperKOOL u...

Страница 16: ...other problems associated with excess condensation Failure to use the condensation drain line tube will void the warranty on the unit Condensate Evaporator The SC units come equipped with a condensat...

Страница 17: ...water 3 Place bottle probe securely into bottle as seen in Figure 1 4 Place the wine bottle in your wine cellar Ensure sensor tip is fully submerged 5 To ensure a consistent temperature place bottle...

Страница 18: ...0 F or for a maximum of ten minutes The unit will then return to normal operation If the evaporator is not above 26 F after the Anti Frost Cycle has ended the red error light will display in the upper...

Страница 19: ...the set button again While the current temperature setting is displayed press the up or down arrows to change set point When the display shows the desired temperature setting press and release the set...

Страница 20: ...into continuous Anti Frost Cycles every 5 minutes call Customer Service for more troubleshooting information CPSM Customer Preference Selection Mode Press and hold the SET button for approximately 5...

Страница 21: ...www whisperkool com Page 19 SC PRO Series WIRING SCHEMATIC...

Страница 22: ...SC PRO 111519 Page 20 1 800 343 9463 WIRING SCHEMATIC...

Страница 23: ...www whisperkool com Page 21 SC PRO Series NOTES...

Страница 24: ...r setpoint Power select switch in wrong position See page 10 for correct switch position Faulty thermostat or wiring Call Customer Service at 1 800 343 9463 Cellar temperature is too warm Possible cau...

Страница 25: ...9463 Evaporator fan runs but compressor does not Possible cause Solution Unit is running an Anti Frost Cycle Check evaporator coil temperature Compressor and or starting components faulty Call Custome...

Страница 26: ...he waterline if draining into a vessel Every Six Weeks Disconnect exterior drain line and check for blockages Quarterly Use a vacuum with brush attachment to clean coils be careful not to crush coil f...

Страница 27: ...US Toll Free 1 800 343 9463 Fax 209 466 4606 ACCESSORIES FOR COOLING UNITS WhisperKOOL offers accessories to enhance and customize your wine cooling unit Exterior Grille The exterior grille protects t...

Страница 28: ...uct to the End User and 2 PARTS Supply to the End User new or rebuilt replacement parts for the Product in exchange for the return of defective parts and 3 FREIGHT Cover normal ground freight charges...

Страница 29: ...ry the limited warranty on this Product 3 Product Installation Requirements A Prior to installing a WhisperKOOL Product the End User must read the WhisperKOOL Owner s Manual and thereafter the End Use...

Страница 30: ...738 East Alpine Avenue Stockton California 95205 8 Miscellaneous Terms and Conditions A Return Policy All return inquiries must be made within thirty 30 calendar days of the original purchase of a Pro...

Страница 31: ...echnical Assistance WhisperKOOL Customer Service is available Monday through Friday from 6 00 a m to 4 00 p m PST The Customer Service representative will be able to assist you with your questions and...

Страница 32: ...WhisperKOOL 1738 E Alpine Ave Stockton CA 95205 1 800 343 9463 www whisperkool com...

Отзывы: