PT-EXPL 020111
Cutting the Hole for the WhisperKOOL Unit
Tools Needed
Sizing the Unit to the Room
Using a level and a pencil, mark a horizontal line on
the wall between the two studs, approximately 1.25”
(or as close as possible if more than 1.25”) from the
ceiling.
Using a ruler or measuring tape, measure 16” down,
and mark another horizontal line parallel to the first
one.
Locate the desired installation location. Using a stud finder, locate the studs on either side of the center point,
and mark them with vertical lines.
Using a saw, cut along the uppermost horizontal line
until your saw reaches the stud. Turn the saw around,
inserting it into the cut you have just made, and cut
toward the opposite stud so that you have a clean hori-
zontal cut between the two studs. Be careful not to cut
into the studs themselves.
Now make the second horizontal cut from stud to stud
on the line 16” below the first cut.
Hammer
Mark the horizontal lines with a level
Saw
Screwdriver
Level
high
Model
4000
Cellar Volume
1000
AMP’s
32
36
AMP’s
9
10
Product Dimensions
14.25” x 15.75” x 25.5”
(cubic feet)
(starting)
(running)
(W x H x D)
14.25” x 22.5” x 27.5”
8000ti
36
10
14.25” x 22.5” x 27.5”
8000ti
36
10
14.25” x 22.5” x 27.5”
8000ti
2000
36
10
14.25” x 22.5” x 27.5”
8000
2000
1000
med
low
500