Connect one end of the test cable to the 
appropriate SEND connector and the other end to 
the mating RECEIVE connector. Turning the 
rotary switch from the OFF position will send 
current to one of the SEND LED indicators and to 
the same contact on the SEND connector. The 
current flows through the cable and into the 
RECEIVE connector and will light the 
corresponding RECEIVE LED in a cable wired to 
the same contact at each end. For cables wired 
pin to pin, rotating through all of the positions 
should light only SEND and RECEIVE LEDs for 
the conductor that the switch is testing. Cables 
with shorted conductors will light additional SEND 
and RECEIVE LEDs identifying which wires the 
conductor being tested is shorted to. Cables with 
open conductors will light only the SEND LED. 
Combinations of shorts and opens will light 
patterns of LEDs that can identify the fault 
conditions within the cable. The SC48 can also 
identify custom wiring configurations.

Operation

Removing the six case screws provides access to 
the 9 Volt battery compartment. The battery 
should be changed when the SEND LED 
becomes dim.