2.  Secure the bottom of the duct with (2) 4.2 x 8 mm screws.

Complete Installation

1.  For non-vented (recirculating) installations only, install 

char

coal filters over metal grease filter

. See the “Range 

Hood Care” section.

2. 

Install metal filters. See the “Range Hood Car

e” section.

3.  Check the operation of the range hood blower and light. 

See the “Range Hood Use” section.

NOTE: T

o get the most efficient use fr

om your new range hood, 

read the “Range Hood Use” section.

RANGE HOOD USE

The range hood is designed to remove smoke, cooking 

vapors, and odors from the cooktop area. For best results, 

start the hood before cooking, and allow it to operate several 

minutes after the cooking is complete to clear all smoke and 

odors from the kitchen.
The hood controls are located on the front side of the canopy.

Range Hood Controls

Operating the light

The On/Off light button controls both lights. Press once 

for On and again for Off.

Operating the blower

The Blower Speed buttons turn the blower on and control the 

blower speed and sound level for quiet operation. The speed 

can be changed anytime during fan operation by pressing the 

desired Blower Speed button.
The Blower Off button turns the blower off.

A

B

C

D

F

E

G

A.  Duct cover holes
B.  Duct cover
C.  Control panel
D.  Glass canopy

E.  Grease filter 
F.  LED lights
G. Grease filter release handle

A

B

C

D

E

A.  Blower speed maximum button 
B.  Blower speed medium button 
C.  Blower speed minimum button
D.  Blower off button
E.  On/Off light button

Содержание WVW51UC0HV0

Страница 1: ...bsite at www whirlpool ca HOTTE DE CUISINIÈRE À MONTAGE MURAL DE 30 ET 36 76 2 ET 91 4 CM Instructions d installation et Guide d utilisation et d entretien Au Canada pour assistance installation ou service composer le 1 800 807 6777 ou visiter notre site Web à www whirlpool ca Table of Contents Table des matières 2 LIB0115584C W11134241C IMPORTANT READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL U...

Страница 2: ...ntains one or more chemicals known to the State of California to cause birth defects or other reproductive harm RANGE HOOD SAFETY 2 INSTALLATION REQUIREMENTS 4 Tools and Parts 4 Location Requirements 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Location 7 Install Range Hood 8 Connect Vent System 8 Make Electrical Connection 9 Install Vent Covers 9 Complete...

Страница 3: ...3 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS ...

Страница 4: ...ve all governing codes and ordinances Have a qualified technician install the range hood It is the installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located behind the left filter on the rear wall of the vent hood Canopy hood location should be away from strong draft areas such as windows doors and strong h...

Страница 5: ...r enclosed area Do not use 4 10 2 cm laundry type wall cap Use metal vent only Rigid metal vent is recommended Plastic or metal foil vent is not recommended The length of vent system and number of elbows should be kept to a minimum to provide efficient performance For the Most Efficient and Quiet Operation Use no more than three 90 elbows Make sure there is a minimum of 24 61 cm of straight vent b...

Страница 6: ...s Ensure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate A...

Страница 7: ... wood For wall anchors drill 7 16 10 mm holes at all locations where wall anchors are being used 6 For wood install 2 5 x 45 mm mounting screws Leave a 1 4 6 4 mm gap between the wall and the back of the screw head to slide range hood into place For wall anchors install the 10 x 60 mm wall anchors and install the 5 4 x 75 mm screws into the wall anchors Tighten until the wall anchors are secure Ba...

Страница 8: ...back draft dampers work properly For non vented recirculating installation only 1 Assemble the air deflector with the duct cover bracket using 4 4 2 x 8 mm screws 2 Measure from the bottom of the air deflector to the bottom of the hood outlet 3 Cut the duct to the measured size X 4 Remove the air deflector 5 Slide the duct onto the bottom of the air deflector 6 Place the assembled air deflector an...

Страница 9: ... from the vent covers 1 When using both upper and lower vent covers push lower cover down onto hood and then lift upper cover to ceiling and install with 2 4 2 x 8 mm screws NOTE For vented installations the upper vent cover may be reversed to hide slots WARNING Electrical Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in de...

Страница 10: ...e several minutes after the cooking is complete to clear all smoke and odors from the kitchen The hood controls are located on the front side of the canopy Range Hood Controls Operating the light The On Off light button controls both lights Press once for On and again for Off Operating the blower The Blower Speed buttons turn the blower on and control the blower speed and sound level for quiet ope...

Страница 11: ...ase handles are toward the front Insert aluminum filter into upper track 4 Push in spring release handle 5 Push up on metal filter and release handle to latch into place Non Vented recirculating Installation Filters The charcoal filter is not washable It should last up to 6 months with normal use Replace with Charcoal Filter Kit See the Assistance or Service section to order To replace charcoal fi...

Страница 12: ...tch Operation POSITION FUNCTION Off Lamps Low Speed Med Speed High Speed No Connection YL GN WH BK YL GN WH WH WH WH BK BK BK BK BU BU BU BU BR BR BR YL YL YL YL RD RD RD BK BK BU EMI Filter LED Driver Brown Black L 3 Blue Yellow M La Brown White L 1 Brown Red L 2 YL GY Output 700mA 2 15 VDC Input 120 VAC Motor Resistance Ω YL GN GY RD YL GN RD BU BU NOTE COMPONENTS AND WIRES DRAWN WITH THE DASHED...

Страница 13: ...rlpool Corporation with any questions or concerns at Whirlpool Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor MI 49022 2692 Please include a daytime phone number in your correspondence In Canada Call the Whirlpool Canada Customer eXperience Centre toll free 1 800 807 6777 or visit our website at www whirlpool ca Our Consultants Provide Assistance With Scheduling of ...

Страница 14: ...se of non genuine Whirlpool parts or accessories 6 Conversion of your product from natural gas or propane gas or reversal of appliance doors 7 Damage from accident misuse abuse fire floods acts of God or use with products not approved by Whirlpool 8 Repairs to parts or systems to correct product damage or defects caused by unauthorized service alteration or modification of the appliance 9 Cosmetic...

Страница 15: ...sation de pièces ou accessoires Whirlpool non authentiques 6 Conversion de votre produit du gaz naturel ou du gaz de propane ou inversion des portes de l appareil 7 Dommages causés par accident mésusage abus incendie inondations catastrophe naturelle ou l utilisation de produits non approuvés par Whirlpool 8 Réparations aux pièces ou systèmes dans le but de rectifier un dommage ou des défauts résu...

Отзывы: