Because Whirlpool Corporation policy includes a continuous commitment to improve 

Dimensions are for planning purposes only. For complete details, see Installation 

our products, we reserve the right to change materials and specifications without notice. 

Instructions packed with product. Specifications subject to change without notice.

ELECTRICAL REQUIREMENTS

DRAIN SYSTEM

A 120 volt, 60 Hz., AC only, 15- or 20-amp, fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is 

recommended that a separate circuit serving only this appliance be provided.

The washer can be installed using the standpipe drain system (floor or wall), the laundry tub drain system, or the floor drain system. 

Select the drain hose installation method you need. 

W10410358A 

  09/2011

Minimum diameter for a standpipe drain: 2" (51 mm). Minimum  

carry-away capacity: 17 gal. (64 L) per minute. Top of standpipe must 

be at least 39" (990 mm) high; install no higher than 96" (2.4 m) from 

bottom of washer. If you must install higher than 96" (2.4 m), you  

will need a sump pump system.

Wall standpipe drain system

Laundry tub drain system

Minimum capacity: 20 gal. (76 L). Top of laundry tub must be at 

least 39" (990 mm) above floor; install no higher than 96" (2.4 m) 

from bottom of washer. 

IMPORTANT:

 To avoid siphoning, no more than 4

1

2

" (114 mm) 

of drain hose should be inside standpipe or below the top of 

wash tub. Secure drain hose with cable tie.

Floor drain system

Floor drain system requires a Siphon Break Kit (Part Number 

285834), 2 Connector Kits (Part Number 285835), and an  

Extension Drain Hose (Part Number 285863) that may be  

purchased separately. To order, please see toll-free phone  

numbers in your “Use and Care Guide.” Minimum siphon break: 

28" (710 mm) from bottom of washer. (Additional hoses may  

be needed.)

Floor standpipe drain system

39"

(990 mm)

4

1

/

2

"

(114 mm)

4

1

/

2

"

(114 mm)

4

1

/

2

"

(114 mm)

30"

(762 mm)

39"

(990 mm)

See requirements for floor standpipe drain system.