MSEX0110i – Wall Mounted Dryer WSI24ABBPH00
Page 17 -21
10.5 – On/Off Switch:
The On/Off Switch can be found inside the Instrument Support, in the right side of Dryer.
When this Switch
is pushed
, its contacts close and Dryer starts operating.
When the Switch
is released
, its contacts open and the Dryer stops operating.
To test the Switch, check continuity between its leads with a multimeter, according to the table below:
When the On/Off Switch is pushed
continuity between leads 1 & 2
continuity between leads 5 & 6
10.6 - Heater
The Heater is located inside of the proper box behind of the Dryer.
To test the Heater, disconnect it from the circuit and check its resistance value (in Ohms) with a Multimeter,
according to the table below:
Tension
Ohmic value
220 V
25 to 28
Ω
KNOB
TERMINALS
SIDE A SIDE B
TERMINAL 1
TERMINAL 2
TERMINAL 5
TERMINAL 6
HEATER
TERMINALS