Excessive Weight Hazard

Use two or more people to move and lift salt

bags.

Failure to do so can result in back or other

injury.

ADD WATER AND SALT TO THE SALT

STOR AGE TANK

Installation Instructions

TEST FOR LEAKS

To prevent air pressure in the water softener and

plumbing system, complete the following steps in

order:

1

. Fully open two or more softened cold water faucets

close to the water softener, located downstream

from the water softener.

2

. Place the bypass valve (single or 3 valve) into the

"bypass" position.  See Figures 7 & 8 on Page 7.

3

. Slowly open the main water supply valve.  Run

water until there is a steady flow from the opened

faucets, with no air bubbles.

4

. Place bypass valve(s) in "service" or soft water posi-

tion as follows:

=

Single bypass valve: Slowly move the valve stem

toward "service," pausing several times to allow

the water softener to fill with water.

=

3 valve bypass: Fully close the bypass valve and

open the outlet valve.  Slowly open the inlet

valve, pausing several times to allow the water

softener to fill with water.

5

. After about three minutes, open a hot water faucet

until there is a steady flow and there are no air bub-

bles, then close this faucet.

6

. Close all cold water faucets and check for leaks at

the plumbing connections that you made.

7

. Check for leaks around clips at softener’s inlet and

outlet.  If a leak occurs at a clip, depressurize the

plumbing (turn off the water supply and open

faucets) before removing clip.  When removing clips

at the softener’s inlet or outlet, push the single

bypass valve body toward the softener (See Figure

15).  Improper removal may damage clips.  Do not

reinstall damaged clips.

1

. Using a container, add about three gallons of clean

water into the salt storage tank.

2

. Add salt to the storage tank.  Use nugget, pellet or

coarse solar salts with less than 1% impurities.

PLUG IN THE POWER SUPPLY

During installation, the water softener wiring may be

moved or jostled from place.  Be sure all leadwire con-

nectors are secure on the back of the electronic board

and be sure all wiring is away from the valve gear and

motor area, which rotates during regenerations.

1

. Plug the power supply into an electrical outlet that is

not controlled by a switch.

NOTE:

The water heater is filled with hard water and,

as hot water is used, it will refill with condi-

tioned water.  In a few days, the hot water will

be fully conditioned.  To have fully conditioned

hot water immediately, wait until the initial

recharge is over.  Then, drain the water heater

(following instructions for water heater) until

water runs cold.

SANITIZE THE WATER SOFTENER /

SANITIZE AFTER SERVICE

1

. Open salt lid, remove the brinewell cover and pour

about 3 oz. (6 tablespoons) of household bleach

into the softener brinewell.  Replace the brinewell

cover.

2

Make sure the bypass valve(s) is in the “service”

(open) position.

3

Start a recharge (regeneration).  

See “Start a Recharge” on Page 13.

4

. After the recharge has completed, fully open a cold

water faucet, downstream from the softener, and

allow 50 gallons of water to pass through the sys-

tem.  This should take at least 20 minutes.  Close

the faucet.

FIG. 15

...depressurize the

plumbing, then push

Bypass Valve body

toward softener

If removing

clips...

Содержание WHES60

Страница 1: ... visit www whirlpoolwatersofteners com When you call please be prepared to provide the model and serial number of your product found on the rating decal located on the back of the controller s top cover System tested and certified by NSF International against NSF ANSI Standard 44 for hardness reduction and efficiency and certified to NSF ANSI Standard 372 How to install operate and maintain your D...

Страница 2: ...afety 4 Before You Start 4 Inspect Shipment 5 Water Conditioning Information 5 Installation Requirements 6 7 Installation Instructions 8 11 Programming the Water Softener 12 13 Customizing Features Options 13 16 Routine Maintenance 16 17 Troubleshooting 18 19 Exploded View Parts List 20 23 Warranty 24 Dimensions 39 18 DIA OUTLET ...

Страница 3: ...on Exchange Resin 1 67 cu ft Pressure Drop at Rated Service Flow 8 7 psig Water Supply Max Hardness 120 gpg Water Supply Max Clear Water Iron 16 ppm Water Pressure Limits minimum maximum 20 125 psi Water Temperature Limits minimum maximum 40 120 F Minimum Water Supply Flow Rate 3 gpm Intermittent Flow 30 PSI 21 gpm Maximum Drain Flow Rate 2 0 gpm Salt Storage Capacity 200 lbs This model is efficie...

Страница 4: ... call Toll Free 1 866 986 3223 Monday Friday 8 am 7 pm EST or visit www whirlpoolwatersofteners com When you call please be prepared to provide the model and serial number found on the rating decal located on the back of the controller s top cover Before You Start The water softener requires a minimum water flow of 3 gallons per minute at the inlet Maximum allowable inlet water pressure is 125 psi...

Страница 5: ...cause it has oxidized before reaching the home It appears as small cloudy yellow orange or reddish suspended particles After the water stands for a period of time the particles settle to the bottom of the container Generally these irons are removed from water by filtra tion Chlorination is also recommended for bacterial iron Colloidal and inorganically bound iron is of ferric or fer rous form that...

Страница 6: ...o condition all water in the home install the water softener close to the water supply inlet and upstream of all other plumbing connections except outside water pipes Outside faucets should remain on hard water to avoid wasting conditioned water and salt A nearby drain is needed to carry away regenera tion discharge drain water Use a floor drain laundry tub sump standpipe or other options check yo...

Страница 7: ... but still have water in house pipes Pipe fittings must be 3 4 minimum Use Copper pipe Threaded pipe PEX Crosslinked Polyethylene pipe CPVC plastic pipe Other pipe approved for use with potable water IMPORTANT Do not solder with plumbing attached to installation adaptors and single bypass valve Soldering heat will damage the adaptors and valve FIG 7 FIG 8 SINGLE BYPASS VALVE Pull out for Service S...

Страница 8: ...ener valve drain tubing to the salt storage tank overflow hose Floor Drain Overflow Drain Elbow Salt Storage Tank Overflow Hose Secure Valve Drain Hose in place over Floor Drain 1 NPT Threaded Adaptor 1 1 2 air gap Plug in Power Supply To Controller 1 Move the water softener into the desired location Set it on a solid level surface IMPORTANT Do not place shims directly under the salt storage tank ...

Страница 9: ...lling the water softener with a plastic bypass valve will break this ground Before beginning installation purchase and securely install two grounding clamps and a 4 copper wire across the location where the softener will be tightly clamping it at both ends as shown in Figure 10 NOTE Check local plumbing and electrical codes for proper installation of the ground wire The installation must conform t...

Страница 10: ...bing Brinewell To Floor Drain Overflow Drain Hose COMPLETE INLET AND OUTLET PLUMBING Measure cut and loosely assemble pipe and fittings from the main water pipe to the inlet and outlet ports of the water softener valve Be sure to keep fittings fully together and pipes squared and straight Be sure hard water supply pipe goes to the water sof tener valve inlet side NOTE Inlet and outlet are marked o...

Страница 11: ...t or outlet push the single bypass valve body toward the softener See Figure 15 Improper removal may damage clips Do not reinstall damaged clips 1 Using a container add about three gallons of clean water into the salt storage tank 2 Add salt to the storage tank Use nugget pellet or coarse solar salts with less than 1 impurities PLUG IN THE POWER SUPPLY During installation the water softener wiring...

Страница 12: ...utton until they do 1 Press the r UP or s DOWN buttons to set the present time Up moves the display ahead down sets the time back Be sure AM or PM is correct NOTE Press buttons and quickly release to slowly advance the display Hold the buttons down for fast advance RECHARGE PROGRAM DATA HOLD TO START PRESS TO SCHEDULE FIG 16 PROGRAM button DOWN button Display RECHARGE button DATA button UP button ...

Страница 13: ...t the clock to the correct time of day NOTE If the water softener was regenerating when power was lost it will now finish the cycle FIG 19 RECHARGE NOW initiated RECHARGE NOW The RECHARGE button is used to initiate an immedi ate recharge 1 Press and hold the RECHARGE button until the words RECHARGE NOW flash in the display The softener enters the fill cycle of regeneration right away RECHARGE NOW ...

Страница 14: ... every few days to keep the resin bed clean The maximum days between recharges may be set from 1 to 15 days as follows NOTE The softener will recharge on its own if need ed even if it is before the set number of days 1 Press the PROGRAM button and hold for three seconds until the Recharge Time screen Figure 26 is displayed 2 Once in this display press the PROGRAM button again and the display in Fi...

Страница 15: ...ins per pound of salt or higher HEAVY DUTY BACKWASH When set to ON the backwash cycle of regeneration will be 22 minutes long instead of the normal 15 minute length This is beneficial on some water sup plies high in iron or sediment content To conserve water when this softener is installed on clean water supplies be sure OFF is set 1 Press the PROGRAM button and hold for three seconds until the Re...

Страница 16: ...RAM button twice and one of the two displays in Figure 34 is shown FIG 33 FIG 34 4 Press the r UP or s DOWN buttons to select gallons or liters 5 Press the PROGRAM button once again to return to the normal time of day screen Routine Maintenance WATER SOFTENER CLEANSER The manufacturer recommends that you use Whirlpool WHE WSC Water Softener Cleanser as directed every four months Lift the brinewell...

Страница 17: ...ot recharged and hard water will result If the storage tank is full of salt it is difficult to tell if you have a salt bridge A bridge may be underneath loose salt Take a broom handle or like tool and hold it next to the water softener Measure the distance from the floor to the rim of the water softener Then gently push the broom handle straight down into the salt If a hard object is felt before t...

Страница 18: ...not in use and no flow through the meter Open a nearby soft water faucet 000 to 140 continual Repeats for each gallon of water passing through the meter 3 Symbols in the display indicate POSITION switch operation See Figure 38 4 Use the RECHARGE button to manually advance the valve into each cycle and check correct switch operation NOTE Be sure water is in contact with the salt and not separated b...

Страница 19: ...ener does not draw brine check for most likely to least likely Dirty or plugged nozzle and venturi see Cleaning the Nozzle and Venturi section Nozzle and venturi not seated on the gasket or gasket deformed Valve seals leaking See Troubleshooting Restriction in valve drain causing a back pres sure bends kinks elevated too high etc See Install Valve Drain Hose section Obstruction in brine valve or b...

Страница 20: ...20 Softener Exploded View 12 Valve Assembly See Pages 22 23 for parts 5 6 7 8 9 13 14 15 17 18 21 20 19 28 22 23 24 25 27 26 16 1 2 3 4 29 11 10 ...

Страница 21: ...T Manufactured and warranted by Ecodyne Water Systems 1890 Woodlane Drive Woodbury MN 55125 Key No Part No Description 7331177 Tank Neck Clamp Kit includes 2 ea of Key Nos 1 2 1 á Clamp Section 2 req 2 á Retainer Clip 2 req 7112963 Distributor O Ring Kit includes Key Nos 3 5 3 á O Ring 2 7 8 x 3 1 4 4 á O Ring 13 16 x 1 1 16 5 á O Ring 2 3 4 x 3 6 7077870 Top Distributor 7 7105047 Repl Bottom Dist...

Страница 22: ...View wear strip seal cross section view 100 101 102 103 104 105 106 107 108 109 110 111 112 117 118 113 140 114 115 119 120 121 122 123 124 125 127 126 116 128 129 131 130 132 133 134 135 136 137 138 139 141 142 143 144 ...

Страница 23: ...123 1 ea of Key Nos 124 125 124 á Turbine Support Shaft 125 á Turbine 126 7309811 Wire Harness Sensor 127 7081201 Retainer Nozzle Venturi 128 7171145 Valve Body 129 7342649 O Ring 1 4 x 3 8 pack of 2 130 1202600 Nut Ferrule 7197777 Nozzle Venturi Assembly incl Key Nos 127 129 131 139 131 7081104 Housing Nozzle Venturi 132 7095030 Cone Screen 133 1148800 Flow Plug 3 gpm 134 7114533 Nozzle Venturi G...

Страница 24: ...ssures not exceeding 125 psi and at water temperatures not exceeding 120 F provided further that the water softener is not subject to abuse misuse alter ation neglect freezing accident or negligence and provided further that the water softener is not damaged as the result of any unusual force of nature such as but not limited to flood hurricane tornado or earthquake Warrantor is excused if failure...