Step 4 - Make Tubing Connections

To Disconnect Tubing:

1. Push the collet inward and hold with a finger while pulling the tubing out.

Fig. 5

tubing

collet (depress to remove tubing)

Fig. 4

NOTE: Remove protective foam plugs before connecting tubes (See Fig. 4).  Discard foam plugs.

1. Allowing some slack, measure and cut a length of 3/8" tubing to connect between the supply fitting

and the filter system inlet, Figure 1. Cut the ends of the tubing square.
2. Insert tubing all the way into the supply fitting and inlet fitting. Pull on the tubing to be sure that it's

held firmly in the fittings.
3. Repeat steps 1 and 2 to connect tubing from the faucet to the filter system outlet, Figure 1.
Tubing Connection (all push-in fitting locations):
This system includes push-in fittings for quick tubing connections. If working with the fittings, do the fol-

lowing.

Connect Tubing: 

1. Use a sharp cutter or knife to cut the end of tubing square.
2. Inspect the end (about 1") of the tubing to be sure there are no nicks, scratches or other rough spots.

If needed cut the tubing again.
3. Push tubing through the collet and all the way into fitting. Full engagement is 3/4" length of tube into

the fitting.
If tubing other than supplied with the system is used, be sure it is of high quality, exact size and round-

ness with a smooth surface.

end of tubing round and smooth,

with no cuts, nicks or flat spots

correct full 3/4" engagement

Tubing correctly cut and connected

Incorrect partial engagement

Remove and discard foam plugs

foam plug

push in fitting

6

Questions? Call toll free 1-866-986-3223 or visit www.ecodynewatertreatment.com

Содержание WHED20

Страница 1: ... tested and certified by NSF International against NSF ANSI Standards 42 53 See performance data sheet for details If you have any questions or concerns when installing operating or maintaining your undersink drinking water filter system call our toll free number 1 866 986 3223 Monday Friday 8 AM 7 PM EST or visit www ecodynewatertreatment com When you call please be prepared to provide the model ...

Страница 2: ...certified for cyst reduction and may be used on disinfected waters that may contain filterable cysts q All plumbing should be done in accordance with local codes and requirements In Massachusetts plumbing code 248 CMR 3 00 and 10 00 shall be adhered to Consult with your licensed plumber q The undersink drinking water filter system works on water pressures of 30 psi minimum to 125 psi maximum If yo...

Страница 3: ...TANT To avoid damaging the sink consult a qualified plumber or installer for drilling procedures in porcelain or stainless steel Locate the water filter housing on the cold water supply pipe under the kitchen and or bathroom sink to filter the cold drinking water Refer to the following drawing shutoff valve filtered water faucet post filter pre filter Blue WATER OUT Yellow WATER IN supply fitting ...

Страница 4: ...and reconnect nut to bottom of fitting Optional Pipe Fittings compression type shown NOTE Be sure to turn off the water supply and open a faucet to drain the pipe Complying with plumbing codes install a fitting on the cold water pipe to adapt 3 8 OD tubing A typical connection is shown in Figure 2B If threaded fittings are used be sure to use pipe joint compound or thread sealing tape on outside t...

Страница 5: ...the countertop next to the sink 2 If drilling is needed make a 1 1 4 dia minimum hole for the faucet 1 Feed the 3 8 tubing that is attached to the faucet through the mounting hole Slide the toggle bolts through the mounting hole Tighten the screws to secure the base flat on the mounting surface Do not overtighten 2 Move the faucet down onto the base Turn 1 4 clockwise to attach the faucet to the b...

Страница 6: ...ection all push in fitting locations This system includes push in fittings for quick tubing connections If working with the fittings do the fol lowing Connect Tubing 1 Use a sharp cutter or knife to cut the end of tubing square 2 Inspect the end about 1 of the tubing to be sure there are no nicks scratches or other rough spots If needed cut the tubing again 3 Push tubing through the collet and all...

Страница 7: ...th replacement element pack WHEEDF conforms to NSF ANSI 42 and 53 for the specific performance claims as verified and substan tiated by test data The rated capacity for this system is 280 gallons 1060 liters at a rated service flow of 0 5 gpm gallons per minute Fig 6 filter cartridge head Turn filter cartridge to the left to remove from head Turn filter cartridge to the right to attach to head 1 T...

Страница 8: ...f the faucet base This LED will flash continuously after 6 months have passed This indicates that it is time to replace the battery and filters Problem Taste and or Odor Cause Pre Post filter expended Correction Replace the filter cartridges Cause System contaminated Correction Sanitize system Call 1 866 986 3223 for instructions Problem Faucet LED indicator light does not function after battery c...

Страница 9: ... as the result of any unusual force of nature such as but not limited to flood hurricane tornado or earthquake Warrantor is excused if failure to perform its warranty obligations is the result of strikes government regulation materials shortages or other circumstances beyond its control THERE ARE NO WARRANTIES ON THE UNDERSINK DRINKING WATER FILTER SYSTEM BEYOND THOSE SPECIFICALLY DESCRIBED ABOVE ...

Страница 10: ...Exploded View 1 2 3 5 7 6 4 4 9 8 10 10 Questions Call toll free 1 866 986 3223 or visit www ecodynewatertreatment com ...

Страница 11: ... Cartridge 2 pack Ù 7333129 Mounting Hardware Kit includes 2 ea of Key Nos 9 10 9 á Hanger Washer 2 req d 10 á Screw 2 req d 7278646 Owner s Manual Ù Please purchase replacement cartridges from the retailer where you bought your drinking water system Not illustrated To order repair parts call toll free 1 866 986 3223 Monday Friday 8 am 7 pm EST Manufactured and warranted by Ecodyne Water Systems 1...

Отзывы: