Gas Dryer
PRODUCT MODEL NUMBERS
W10573707B
10/2013
WGD70HEB, WGD71HEB, WGD80HEB, WGD86HEB,
WGD88HEA, WGD94HEA, WGD96HEA, WGD98HEB
27"
(686 mm)
38
3
/
4
" Min.
(984 mm)
39" Max.
(990 mm)
Back view:
6
1
/
4
"
(159 mm)
29
7
/
8
"*
(759 mm)
3
1
/
2
"*
(89 mm)
5
3
/
4
"*
(146 mm)
6
1
/
8
"*
(156 mm)
14
3
/
8
"
(365 mm)
25
3
/
4
"
(654 mm)
3
/
4
"*
(18 mm)
NOTE:
Most installations require a minimum of 5" (127 mm)
clearance behind dryer for exhaust vent with elbow. See “Venting
Requirements.”
Side view:
Front view:
* Approx. measurement
DRYER DIMENSIONS
Gas
* Approx. measurement
Water inlet
(Steam Models Only)
Vent
18" min.
(457 mm)
1"
(25 mm)
5"
(127 mm)
24 in.
2
min.
(155 cm
2
)
48 in.
2
min.
(310 cm
2
)
3"
(76 mm)
3"
(76 mm)
1"
(25 mm)
Recommended installation clearances (dryer only):
*
*
0" (0 mm) spacing is allowed.
*
Installation spacing for recessed area
or closet installation
All dimensions show recommended and minimum spacing allowed.
■
Additional spacing should be considered for ease of
installation and servicing.
■
Additional clearances might be required for wall, door, floor moldings, dryer venting, and gas line.
■
Additional spacing should be considered on all sides
of the dryer to reduce noise transfer.
■
For closet installation, with a door, minimum ventilation openings in the top and bottom of the door
are required. Louvered doors with equivalent ventilation openings are acceptable.
■