background image

6

Electrical Requirements

IMPORTANT:

 The range must be electrically grounded in 

accordance with local codes and ordinances, or in the absence 

of local codes, with the National Electrical Code, ANSI/NFPA 70 

or Canadian Electrical Code, CSA C22.1.
This range is equipped with an electronic ignition system that will 

not operate properly if plugged into an outlet that is not properly 

polarized.
If codes permit and a separate ground wire is used, it is 

recommended that a qualified electrical installer determine that 

the ground path is adequate.
A copy of the above code standards can be obtained from:

National Fire Protection Association 

1 Batterymarch Park 

Quincy, MA 02169-7471

CSA International 

8501 East Pleasant Valley Road 

Cleveland, OH 44131-5575

 

A 120-volt, 60 Hz., AC-only, 15-amp fused, ground and 

polarized electrical circuit is required. A time-delay fuse or 

circuit breaker is also recommended. It is recommended that 

a separate circuit serving only this range be provided.

 

Electronic ignition systems operate within wide voltage limits, 

but proper grounding and polarity are necessary. Check that 

the outlet provides 120-volt power and is correctly grounded.

 

This gas range is not required to be plugged into a GFCI 

(Ground-Fault Circuit Interrupter) outlet. It is recommended 

that you not plug an electric spark ignition gas range or any 

other major appliance into a GFCI wall outlet as it may cause 

the GFCI to trip during normal cycling.

 

Performance of this range will not be affected if operated 

on a GFCI-protected circuit. However, occasional nuisance 

tripping of the GFCI breaker is possible due to the normal 

operating nature of electronic gas ranges.

 

The tech sheet and wiring diagram are located on the back 

of the range in a plastic bag.

NOTE:

 The metal chassis of the range must be grounded in 

order for the control panel to work. If the metal chassis of the 

range is not grounded, no keypads will operate. Check with 

a qualified electrician if you are in doubt as to whether the 

metal chassis of the range is grounded.

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.

WARNING

Gas Supply Requirements

Observe all governing codes and ordinances.

IMPORTANT:

 This installation must conform with all local codes 

and ordinances. In the absence of local codes, installation must 

conform with American National Standard, National Fuel Gas 

Code ANSI Z223.1 - latest edition or CAN/CGA B149 -  

latest edition.

IMPORTANT:

 Leak testing of the range must be conducted 

according to the manufacturer’s instructions.

Type of Gas

Natural Gas:

 

This range is factory set for use with Natural gas. See “Gas 

Conversions” section. The model/serial/rating plate located 

on the oven frame behind the top left-hand side of the oven 

door has information on the types of gas that can be used. If 

the types of gas listed do not include the type of gas available, 

check with the local gas supplier.

Propane Gas Conversion:

Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas 

specified on the model/serial/rating plate for use with a different 

gas without consulting the serving gas supplier. See “Gas 

Conversions” section.

Gas Supply Line

 

Provide a gas supply line of ¾" (1.9 cm) rigid pipe to the 

range location. A smaller size pipe on longer runs may 

result in insufficient gas supply. With Propane gas, piping or 

tubing size can be ½" (1.3 cm) minimum. Usually, Propane 

gas suppliers determine the size and materials used in the 

system.

 

NOTE:

 Pipe-joint compounds that resist the action of 

Propane gas must be used. Do not use TEFLON

®†

 tape.

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make 

sure gas pressure does not exceed 14" (36 cm) water 

column. 
Examples of a qualified person include: 
licensed heating personnel, 

authorized gas company personnel, and

authorized service personnel.
Failure to do so can result in death, explosion, or fire.

®

TEFLON is a registered trademark of Chemours.

Содержание WEG515S0FV0

Страница 1: ... Tip Bracket Is Installed and Engaged 11 Electronic Ignition System 11 Remove Replace Drawer 12 Oven Door 12 Complete Installation 12 GAS CONVERSIONS 13 Propane Gas Conversion 13 Natural Gas Conversion 16 Adjust Flame Height 19 SÉCURITÉ DE LA CUISINIÈRE 21 EXIGENCES D INSTALLATION 23 Outils et pièces 23 Exigences d emplacement 23 Spécifications électriques 25 Spécifications de l alimentation en ga...

Страница 2: ...proved by UL or CSA For more information contact your gas supplier If a gas leak is detected follow the What to do if you smell gas instructions WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any othe...

Страница 3: ...lled Install anti tip bracket to floor or wall per installation instructions Slide range back so rear range foot is engaged in the slot of the anti tip bracket Re engage anti tip bracket if range is moved Do not operate range without anti tip bracket installed and engaged Failure to follow these instructions can result in death or serious burns to children and adults Anti Tip Bracket To verify the...

Страница 4: ...l governing codes and ordinances Do not obstruct flow of combustion and ventilation air It is the installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located behind the oven door on the top left hand side of the oven frame The range should be located for convenient use in the kitchen Recessed installations mu...

Страница 5: ... 9 cm C Model serial rating plate located behind the oven door on the top left hand side of the oven frame D 36 91 4 cm height to top of cooktop edge with leveling legs screwed in all the way E 2825 64 72 1 cm max depth from front of console to back of range F 291 64 73 7 cm max depth from handle to back of range Cabinet Dimensions Cabinet opening dimensions shown are for 25 64 0 cm countertop dep...

Страница 6: ...he range is grounded Electrical Shock Hazard Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock WARNING Gas Supply Requirements Observe all governing codes and ordinances IMPORTANT This installation must conform with all local codes and ordinances In the ...

Страница 7: ...e 14 35 5 cm WCP Propane Gas Minimum pressure 12 30 5cm WCP Maximum pressure 14 35 5 cm WCP Contact local gas supplier if you are not sure about the inlet pressure Burner Input Requirements Input ratings shown on the model serial rating plate are for elevations up to 2 000 ft 609 6 m For elevations above 2 000 ft 609 6 m ratings are reduced at a rate of 4 for each 1 000 ft 304 8 m above sea level ...

Страница 8: ...e people to move and install range Failure to do so can result in back or other injury Install Anti Tip Bracket 1 Remove the anti tip bracket from the inside of the oven 2 Determine which mounting method to use floor or wall If you have a stone or masonry floor you can use the wall mounting method If you are installing the range in a mobile home you must secure the range to the floor This anti tip...

Страница 9: ... is not adjust the leveling legs to the correct height The leveling legs can be loosened to add up to a maximum of 1 2 5 cm A minimum of 3 16 5 mm is needed to engage the anti tip bracket NOTE If height adjustment is made when range is standing tilt the range back to adjust the front legs and then tilt forward to adjust the rear legs 4 When the range is at the correct height check that there is ad...

Страница 10: ...f valve Securely tighten all gas connections If connected to propane have a qualified person make sure gas pressure does not exceed 14 36 cm water column Examples of a qualified person include licensed heating personnel authorized gas company personnel and authorized service personnel Failure to do so can result in death explosion or fire A B C D E F G H A Gas pressure regulator B Use pipe joint c...

Страница 11: ...start up If a burner does not light at this point turn the control knobs to the off position and contact your dealer or authorized service company for assistance Please reference the Warranty section of the User Guide to contact service If the cooktop low burner flame needs to be adjusted for any of the burners see the Adjust Flame Height section Check Operation of Oven Bake Burner 1 Press BAKE 2 ...

Страница 12: ...moval and installation procedures Complete Installation 1 Check that all parts are now installed If there is an extra part go back through the steps to see which step was skipped 2 Check that you have all of your tools 3 Check that you have all of the range accessories especially oven racks These accessories may be in the range packaging 4 Dispose of recycle all packaging materials 5 Check that th...

Страница 13: ...he closed position 2 Unplug range or disconnect power To Convert Gas Pressure Regulator Natural Gas to Propane Gas 1 Remove the storage drawer See the Remove Replace Drawer section 2 Locate gas pressure regulator at rear of the drawer compartment IMPORTANT Do not remove the gas pressure regulator WARNING Tip Over Hazard A child or adult can tip the range and be killed Install anti tip bracket to f...

Страница 14: ...e the orifice spuds shipped in the literature package in the oven Gas orifice spuds are stamped with a number and have a groove in the hex area Replace the Natural gas orifice spud with the correct Propane gas orifice spud Refer to the following chart for correct Propane gas orifice spud ratings and to spud holder card for proper placement Propane Gas Orifice Spud Chart for Surface Burners Burner ...

Страница 15: ...the front frame and then lower the rear of the oven bottom panel into the oven 11 Reattach the oven bottom panel with 2 screws and 2 washers A B A Bake burner B Screws A A Oven orifice A A Orifice spud To Convert Oven Broil Burner Natural Gas to Propane Gas on some models 1 Remove the 1 screw from the broil burner 2 Remove the flame spreader 3 Remove the broil burner from the broil burner orifice ...

Страница 16: ...e inner cone Propane gas flames have a slightly yellow tip 4 Refer to Complete Installation in the Installation Instructions section of this manual to complete this procedure IMPORTANT Make sure to save the orifices that have just been replaced in the conversion Natural Gas Conversion 1 Turn the manual shut off valve to the closed position 2 Unplug range or disconnect power To Convert Gas Pressure...

Страница 17: ...er base A B C D A Igniter electrode B Orifice spud C Orifice spud holder D Screws 4 Gas orifice spuds are stamped with a number on the side Replace the Propane gas orifice spud with the correct Natural gas orifice spud Refer to the following chart for the correct Natural gas orifice spud placement Natural Gas Orifice Spud Chart Burner Rating Size mm ID number 15 000 BTU 1 75 175 9 500 BTU 1 35 135...

Страница 18: ...ert Oven Broil Burner Propane Gas to Natural Gas on some models 1 Remove 1 screw from the broil burner 2 Remove the flame spreader 3 Remove the broil burner from the broil burner orifice hood NOTE The broil burner will hang in the back of the oven while you are changing the orifice hood 4 Apply masking tape to the end of a 3 8 1 cm nut driver to help hold the gas orifice spud in the nut driver whi...

Страница 19: ...ds to Be Adjusted 1 Light 1 burner and turn to lowest setting 2 Remove the control knob Hold the knob stem with a pair of pliers Use a small flatblade screwdriver to turn the screw located in the center of the control knob stem until the flame is the proper size Turning the screw clockwise will increase the flame size and counterclockwise will decrease the flame size 3 Replace the control knob 4 T...

Страница 20: ...ws B Oven bottom 4 If the oven bake flame needs to be adjusted locate the air shutter near the center rear of the drawer cavity behind the access panel Loosen the locking screw and rotate the air shutter until the proper flame appears Tighten locking screw 5 Push the Off pad when finished 6 Reinstall the oven bottom and the storage drawer see the Remove Replace Drawer section Adjust Oven Broil Bur...

Отзывы: