Because Whirlpool Corporation policy includes a continuous commitment to improve 

Dimensions are for planning purposes only. For complete details, see Installation 

our products, we reserve the right to change materials and specifications without notice. 

Instructions packed with product. Specifications subject to change without notice.

     To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical 

supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. Connect to an individual 

branch circuit. Do not have a fuse in the neutral or grounding circuit.

Drain System

Minimum diameter for a standpipe drain: 2" (51 mm). Minimum 

carry-away capacity: 17 gal. (64 L) per minute. A 1/4" (6 mm) 

diameter to 1" (25 mm) diameter Standpipe Adapter Kit is 

available. Top of standpipe must be at least 30" (762 mm) high; 

install no higher than 72" (1.8 m) from bottom of dryer.

IMPORTANT:

 Only 4.5" (114 mm) of drain hose should be inside 

standpipe; do not force excess hose into standpipe.

Wall standpipe drain system

4.5"

(114 mm)

Floor standpipe drain system

4.5"

(114 mm)

4.5"

(114 mm)

See requirements for floor standpipe drain system.

Drain system can be installed using a floor drain, wall standpipe,  floor standpipe, or laundry tub. Select method you need. 

IMPORTANT:

 To avoid siphoning, only 4.5" (114 mm) of drain hose should be inside standpipe. Always secure drain hose with 

cable tie.

Laundry tub drain system

Minimum capacity: 20 gal. (76 L). Top of laundry tub must be

at least 30" (762 mm) above floor; install no higher than

72" (1.8 m) from bottom of dryer.

IMPORTANT:

 Only 4.5" (114 mm) of drain hose should lay

on side of laundry tub. Do not lay the hose at the bottom of tub.

min.

30"

(762 mm)

4.5"

(114 mm)

4.5"

(114 mm)

Remove the U-bend at the end of the drain hose by cuttingthe 

hose at the end of the U-bend for the floor drain system as 

shown in the picture above.  

 

NOTE: 

Cut hose so that no more than 4.5" (114 mm) of the hose 

is in the floor drain to avoid siphoning.

Floor drain system

Electrical Requirements