2.

Slide the bracket over the top of the drum
to access the machine control electronics
connectors and mounting screw. See figure 17.

3.

Remove all the wire connections to the
machine control electronics. See figure 18.

4.

Remove the screw holding the machine control
electronics assembly to the mounting bracket.
See figure 17.

5.

There are two plastic legs on the front of the
machine control electronics that slide under the
mounting bracket.

There is one plastic leg on the rear of the
machine control electronics that slides
under the mounting bracket.

There is a locking tab on the bottom of the
machine control electronics that snaps into
the mounting bracket.

Press the locking tab on the bottom of the
machine control electronics and slide the
assembly to the front, then lift.

3.

Gently remove the decorative trim that
surrounds the door and upper console by
unsnapping it from the dryer. See figure 20.

4.

Slide the console up and off of the dryer.
See figure 19.

5.

The console mounting bracket is fastened to
the console front panel with two latches at both
sides of the console assembly. Unlatch the
bracket gently with a screwdriver while pulling
the mounting bracket assembly out. See
figure 19.

6.

The console electronics is split into two
assemblies connected by two cables. Each
assembly is fastened to the decorative piece
by four plastic latches. To remove these
assemblies, gently compress the plastic
latches while pulling up on the assembly. For
the cycle selector assembly, the cycle selector
knob must first be removed by firmly pulling
on it or gently prying it straight upward. See
figure 21, page 11.

Console Electronics and Housing
Assembly

The console panel must be removed to access the
console electronics and housing assembly.

1.

Perform steps 1 and 2 under Accessing &
Removing the Electronic Assemblies, page 9,
and disconnect the P2 and P5 harnesses from
the machine control.

2.

Remove the screw that fastens the assembly
to the machine control mounting bracket
(figure 17), and the two screws that fasten the
console assembly to the dryer (figure 19).

P9

1

5

1

P14

P2

3

1

1

6

1

1

8

3

P5

P3

1

P13

1

P/N

XXX

XXX

Rev

X

Date

Code

YDD

D-xx

XXX

X-X

XX

MAD

EIN

COO

N.O.

Black

COM

Red

Heater

Relay 1

Motor

Relay

Black-White

White

Green-Yellow

Brown

Lt. Blue Black

Yellow-Red

Open (Gas)

Black (Gas)

Red-White (Gas)

P4

N.O.
Blue

Water Valve

Relay

COM

Red

P8

Figure 18.

Machine control electronics.

Figure 20.

Remove the decorative trim.

Machine Control Electronics

Bracket Screws

FRONT

Machine Control

Electronics Mounting Screw

Figure 17.

Remove machine control electronics

from mounting bracket.

Figure 19.

Remove the console panel to access

the console electronics and housing assembly.

Tan

Содержание WED9600TA1

Страница 1: ...If there are no saved fault codes or active fault codes all indicators on the console will momentarily turn off then stay on with 8 88 displayed Continue with diagnostics 4 If entry into Diagnostic Test Mode is unsuccessful choose a different button except Pause Cancel and Controls Lock Unlock and repeat step 2 If no indicators come on after repeating step 2 using a different button go to TEST 1 p...

Страница 2: ...r is cold the countdown will start at 50 seconds NOTE If the dryer is extremely cold less than 40 F 4 4 C the air flow may not be detected properly and will be displayed If the dryer is hot the countdown timer will start at 30 seconds cool down period followed by an additional 50 second countdown A Dryness Level modifier LED will also be illuminated to indicate the air flow range corresponding to ...

Страница 3: ...See TEST 3 page 5 Moisture Sensor Open F 28 flashes if the moisture sensor strip is open This fault code appears ONLY when in the Diagnostic Test Mode See TEST 5 page 8 Moisture Sensor Shorted F 29 flashes if the moisture sensor strip has shorted This fault code appears ONLY when in the Diagnostic Test Mode See TEST 5 page 8 Moisture Sensor Strips Heater Assembly Door Switch See Accessing Removing...

Страница 4: ...3 If indicators still do not light perform TEST 2 page 5 GAS DRYER 1 Unplug dryer or disconnect power 2 Remove the cover plate from the top right corner of the back of the dryer See figure 3 3 Check that the power cord is firmly connected to the dryer s wire harness See figure 5 4 Access the machine control electronics without disconnecting any wiring to the control board See figure 17 page 10 5 W...

Страница 5: ...ction Thermal fuse no Belt belt switch Drive motor Centrifugal switch Door switch Machine control electronics See ESD information page 1 1 Unplug dryer or disconnect power 2 Access the machine control electronics and measure the resistance across P8 4 and P9 1 See Accessing Removing the Electronic Assemblies page 9 If resistance across P8 4 and P9 1 is in the range of 1 to 6 Ω replace the machine ...

Страница 6: ... cut off high limit thermostat and heater If connections look good check for continuity across each of these components Replace the heater if it is electrically open Replace both the thermal cut off and inlet thermistor high limit thermostat assembly if either the thermal cut off or the high limit thermostat is electrically open 5 If no open circuit is detected remove the P4 connector then measure...

Страница 7: ...et temperature using an inlet thermistor that is part of the high limit thermostat assembly 1 Activate the Diagnostic Test Mode See procedure on page 1 2 If F 24or F 25 is a displayed error in the Diagnostic Test Mode the inlet thermistor or wire harness is either open or shorted Unplug dryer or disconnect power Check wire connections at the machine control electronics and inlet thermistor See Acc...

Страница 8: ...f a small resistance is not measured continue with step 8 8 Measure the resistance across each of the outermost contacts and the center terminal ground connection If a resistance less than infinity is measured replace the sensor harness 9 If moisture sensor diagnostic test passes check the thermistor Perform TEST 4a page 7 If the problem persists after replacing the moisture sensor and thermistor ...

Страница 9: ...oes not start replace the machine control electronics TEST 8 Water Valve Activate the Diagnostic Test Mode as shown on page 1 Press Start and verify that water is being sprayed in the drum See figure 14 If no water is sprayed in the drum 1 Perform steps in Accessing Removing the Electronic Assemblies at right and check that the wires are connected to the water valve relay on the machine control el...

Страница 10: ... out See figure 19 6 The console electronics is split into two assemblies connected by two cables Each assembly is fastened to the decorative piece by four plastic latches To remove these assemblies gently compress the plastic latches while pulling up on the assembly For the cycle selector assembly the cycle selector knob must first be removed by firmly pulling on it or gently prying it straight u...

Страница 11: ...0 6446357 6597144 6604298 6685241 6732447 6784673 6819255 D314261 D314262 D457991 D457992 D495453 REMOVING THE BACK PANEL 1 Unplug dryer or disconnect power 2 Remove the two rear screws from the top panel and slide the top panel to the rear to remove 3 Remove the cover plate disconnect the power cord and remove ground screw 4 Remove the metal spring clip between the back panel and the exhaust outl...

Страница 12: ...7 3 0 SENSOR DOOR NEUTRAL MOTOR MTR CS MOIST MOIST RTN MODEL MODEL RTN OUTLET TEMP OUTLET TEMP RTN MACHINE CONTROL ELECTRONICS Y R P13 1 P13 2 P4 4 P4 5 P4 3 P4 6 R OUTLET THERMISTOR 10 k P9 2 L1 BR L1 LINE BK HEATER V HEATER RTN N O COM BK BK BK R R W NC HIGH LIMIT THERMOSTAT 295 F 146 C THERMAL CUT OFF 352 F 178 C HEATER 7 8 11 8 DRUM LAMP G Y P4 2 INLET TEMP RTN R 240 VOLTS 120 VOLTS P2 1 VDD P...

Отзывы: