INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.

Tools needed

Parts supplied

Check that all parts are included. 

3 - 10-32 hex nuts (attached to terminal block)

3 - Terminal lugs

Anti-tip bracket kit

Anti-tip bracket must be securely mounted to subfloor. Thickness 
of flooring may require longer screws to anchor bracket to 
subfloor. Longer screws are available from your local hardware 
store.

Parts needed

If using a power supply cord kit:

A UL listed power supply cord kit marked for use with ranges. 
The cord should be rated at 250 volts minimum, 40 amps or 
50 amps that is marked for use with nominal 1

³⁄₈

" (3.5 cm) 

diameter connection opening and must end in ring terminals 
or open-end spade terminals with upturned ends.

A UL listed strain relief.

Check local codes. Check existing electrical supply. See 
“Electrical Requirements” section.
It is recommended that all electrical connections be made by a 
licensed, qualified electrical installer.

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.  

It is the installer’s responsibility to comply with installation 
clearances specified on the model/serial rating plate. The 
model/serial rating plate is located on the left side frame 
behind the storage drawer panel.

The range should be located for convenient use in the kitchen.

To eliminate the risk of burns or fire by reaching over heated 
surface units, cabinet storage space located above the 
surface units should be avoided. If cabinet storage is to be 
provided, the risk can be reduced by installing a range hood 
that projects horizontally a minimum of 5" (12.7 cm) beyond 
the bottom of the cabinets.

Cabinet opening dimensions that are shown must be used. 
Given dimensions are minimum clearances.

The floor anti-tip bracket must be installed. To install the anti-
tip bracket shipped with the range, see “Install Anti-Tip 
Bracket” section.

Grounded electrical supply is required. See “Electrical 
Requirements” section.

IMPORTANT: To avoid damage to your cabinets, check with your 
builder or cabinet supplier to make sure that the materials used 
will not discolor, delaminate or sustain other damage. This oven 
has been designed in accordance with the requirements of UL 
and CSA International and complies with the maximum allowable 
wood cabinet temperatures of 194° (90°C).

Mobile Home - Additional Installation Requirements

The installation of this range must conform to the Manufactured 
Home Construction and Safety Standard, Title 24 CFR, Part 3280 
(formerly the Federal Standard for Mobile Home Construction and 
Safety, Title 24, HUD Part 280). When such standard is not 
applicable, use the Standard for Manufactured Home 
Installations, ANSI A225.1/NFPA 501A or local codes.

Mobile home installations require:

When this range is installed in a mobile home, it must be 
secured to the floor during transit. Any method of securing the 
range is adequate as long as it conforms to the standards 
listed above.

Four-wire power supply cord or cable must be used in a 
mobile home installation. The appliance wiring will need to be 
revised. See “Electrical Connection” section.

Tape measure

Flat-blade screwdriver

Level

Hammer

Hand or electric drill

Wrench or pliers

Marker or pencil

Masking tape

¼" drive ratchet

¼" nut driver 

³⁄₈

" and 

⁵⁄₁₆

" nut driver

¹⁄₈

" (3.2 mm) drill bit (for 

wood floors)

³⁄₁₆

" (4.8 mm) carbide-tipped 

masonry drill bit (for 
concrete/ceramic floors)

Tin snips or large wire cutters 
(for cutting ground strap if 
necessary)

A. Anti-tip bracket
B. Plastic anchors (2)

C. #10 x 1

¹⁄₂

" screws (2)

A

B

C

Содержание W10252706A

Страница 1: ...he potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can ...

Страница 2: ...mum of 5 12 7 cm beyond the bottom of the cabinets Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances The floor anti tip bracket must be installed To install the anti tip bracket shipped with the range see Install Anti Tip Bracket section Grounded electrical supply is required See Electrical Requirements section IMPORTANT To avoid damage to your cabinets...

Страница 3: ...codes Do not use an extension cord Be sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances A copy of the above code standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 WARNING Improper connection of the equipment groundi...

Страница 4: ... The ground must be revised so the green ground wire of the 4 wire power supply cord is connected to the cabinet See Electrical Connection Grounding through the neutral conductor is prohibited for new branch circuit installations 1996 NEC mobile homes and recreational vehicles or an area where local codes prohibit grounding through the neutral conductor When a 4 wire receptacle of NEMA Type 14 50R...

Страница 5: ...ount anti tip bracket to wood floor drill two 3 2 mm holes at the positions marked on the bracket template Remove template from floor To mount anti tip bracket to concrete or ceramic floor use a 4 8 mm masonry drill bit to drill 2 holes at the positions marked on the bracket template Remove template from floor Tap plastic anchors into holes with a hammer 6 Align anti tip bracket holes with holes i...

Страница 6: ...down and toward you to remove cover from range 3 Remove plastic tag holding three 10 32 hex nuts from the middle post of the terminal block 4 Add strain relief Style 1 Power supply cord strain relief Remove the knockout for the power supply cord WARNING Electrical Shock Hazard Disconnect power before servicing Use a new 40 amp power supply cord Plug into a grounded outlet Failure to follow these i...

Страница 7: ...he neutral 1 Part of metal ground strap must be cut out and removed 2 Use a Phillips screwdriver to remove the ground link screw from the back of the range Save the ground link screw and the end of the ground link under the screw A UL listed strain relief A Removable retaining nut B Conduit A A B If your home has And you will be connecting to Go to Section 4 wire receptacle NEMA type 14 50R A UL l...

Страница 8: ...g chassis ground conductor to neutral wire of power supply cord 1 Feed the power supply cord through the strain relief on the cord conduit plate on bottom of range Allow enough slack to easily attach the wiring to the terminal block 2 Use nut driver to connect the neutral white wire to the center terminal block post with one of the 10 32 hex nuts 3 Connect line 2 red and line 1 black wires to the ...

Страница 9: ...t remove the setscrew on the front of the terminal lug and insert exposed wire end through bottom of terminal lugs Securely tighten setscrew to torque as shown in the following Bare Wire Torque Specifications chart Bare Wire Torque Specifications Attaching terminal lugs to the terminal block 20 lbs in 2 3 N m 5 Use a hex or Phillips screwdriver to connect the bare green ground wire to the range wi...

Страница 10: ... Verify Anti Tip Bracket Location 1 On models with a storage drawer pull drawer open to first stop position Lift front of drawer to clear white wheels in drawer guides Remove drawer and set it aside on a covered surface On models with a warming drawer the rear leg cannot be seen by removing the warming drawer It will be necessary to view the rear foot from outside the range 2 To check that the ant...

Страница 11: ...ot operate check the following Household fuse is intact and tight or circuit breaker has not tripped Range is plugged into an outlet Electrical supply is connected See Troubleshooting in the Use and Care Guide When the range has been on for 5 minutes check for heat If range is cold turn off the range and contact a qualified technician Moving the Range When moving range slide range onto cardboard o...

Страница 12: ...P BRACKET TEMPLATE Cut on dotted lines and place the left edge against the left side cabinet and the top edge against the rear wall Left edge Top edge W10252706A 2009 All rights reserved 3 09 Printed in U S A ...

Отзывы: