20
| CLEANING AND SANITIZING YOUR VESSI™ FERMENTOR & DISPENSER
REMOVE HEAVY SOLIDS
FROM VESSEL
1
Prepare at least 2 gallons
of brewers detergent�
HELPFUL HINT: PBW
®
(Powdered
Brewery Wash) is a standard detergent
used in this application� For ordering
information, see the “Accessories and
Supplies
”
section� We recommend
mixing brewers detergent in a standard
5-gallon bucket�
2
Remove the 8" stainless steel cap,
gasket, and tri-clamp� Add them to
the bucket of brewers detergent�
3
Check that the 2" cap is attached
to the bottom of the fermenting
vessel and that the tri-clamp is
securely hand-tightened�
4
Pour 2 quarts (64 oz) of prepared
brewers detergent liquid into the
vessel� Using a non-scratch scrub
sponge (not provided), scrub the
inside of the vessel, as well the
groove and neck at the top of
the vessel�
IMPORTANT: The inside of the
fermentor has a polished finish� Use
only non-scratch scrub sponges�
5
Remove the bottom 2" cap to empty
contents into the collection pan�
6
IMPORTANT: Inspect the interior
of the vessel to ensure all solids
are removed before proceeding�
If needed, use additional water
to rinse solids from the vessel�
7
Using a non-scratch scrub sponge,
scrub the groove and neck at the
bottom of the vessel�
CLEANING AND SANITIZING YOUR VESSI™
FERMENTOR & DISPENSER
Содержание Vessi
Страница 1: ...FERMENTOR DISPENSER W10894187A ...