Cabinet Dimensions

*For non-vented (recirculating) installations

IMPORTANT:

Minimum distance “X”: 24" (61.0 cm) from electric cooking 
surface.
Minimum distance “X”: 27" (68.6 cm) from gas cooking 
surfaces.
Suggested maximum distance “X”: 36" (91.4 cm)

The chimneys can be adjusted for different ceiling heights. See 
the following chart.

*NOTE: The range hood chimneys are adjustable and designed 

to meet varying ceiling or soffit heights depending on the 
distance “X” between the bottom of the range hood and the 
cooking surface. For higher ceilings, a Stainless Steel Chimney 
Extension Kit Part Number W10337357 is available from your 
dealer or an authorized parts distributor. The chimney extension 
replaces the chimney shipped with the range hood.

Venting Requirements

(vented models only)

Vent system must terminate to the outdoors, except for non-
vented (recirculating) installations.

Do not terminate the vent system in an attic or other enclosed 
area.

Do not use 4" (10.2 cm) laundry-type wall cap.

Use metal vent only. Rigid metal vent is recommended. 
Plastic or metal foil vent is not recommended.

The length of vent system and number of elbows should be 
kept to a minimum to provide efficient performance.

For the most efficient and quiet operation:

Use no more than three 90° elbows.

Make sure there is a minimum of 24" (61 cm) of straight vent 
between the elbows if more than 1 elbow is used.

Do not install 2 elbows together.

Use clamps to seal all joints in the vent system.

The vent system must have a damper. If the roof or wall cap 
has a damper, do not use the damper supplied with the range 
hood.

Use caulking to seal exterior wall or roof opening around the 
cap.

The size of the vent should be uniform.

Cold Weather Installations

An additional back draft damper should be installed to minimize 
backward cold air flow and a thermal break should be installed to 
minimize conduction of outside temperatures as part of the vent 
system. The damper should be on the cold air side of the thermal 
break.

The break should be as close as possible to where the vent 
system enters the heated portion of the house.

Makeup Air

Local building codes may require the use of makeup air systems 
when using ventilation systems greater than specified CFM of air 
movement. The specified CFM varies from locale to locale. 
Consult your HVAC professional for specific requirements in your 
area.

Venting Methods

This canopy hood is factory set for venting through the roof or 
wall.

A 6" (15.2 cm) round vent system is needed for installation (not 
included). The hood exhaust opening is 6" (15.2 cm) round.

NOTE: Flexible vent is not recommended. Flexible vent creates 
back pressure and air turbulence that greatly reduce 
performance.

Vent system can terminate either through the roof or wall. To vent 
through a wall, a 90° elbow is needed.

Rear discharge

A 90° elbow may be installed immediately above the hood.

Vented Installations

Min. ceiling height

Max. ceiling height

Electric cooking 
surface

7' 

5

" (2.26 m)

9' 

2

" (2.79 m)

Gas cooking 
surface

7' 

8

" (2.34 m)

9' 

2

" (2.79 m)

Non-vented (recirculating) Installations

Min. ceiling height

Max. ceiling height

Electric cooking 
surface

7' 

5

" (2.26 m)

9' 

6

" (2.9 m)

Gas cooking 
surface

7' 

8

" (2.34 m)

9' 

6

" (2.9 m)

7

¹⁄₄

" (18.4 cm)

6⁵⁄₈

" (16.8 cm)

2" (5.1 cm) min.
6" (15.2 cm) min.*

Centerline

Side

cabinet

Side

cabinet

Vent and power

supply cable

entry location

Cooking surface

30" (76.2 cm)

15" (38.1 cm)

7

³⁄₈

" (18.7 cm)

“X”

bottom of 

canopy 

to cooking 

surface

Содержание UXW6530BSS

Страница 1: ...ite at www whirlpool com or www whirlpool ca HOTTE DE CUISINIÈRE CONFIGURÉE EN ÎLOT À MONTAGE MURAL 30 76 2 CM Instructions d installation et Guide d utilisation et d entretien Au Canada pour assistance installation ou service composez le 1 800 807 6777 ou visitez notre site web à www whirlpool ca Table of Contents Table des matières 2 IMPORTANT READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE...

Страница 2: ... A 14 In Canada 14 Accessories 14 WARRANTY 15 TABLE DES MATIÈRES SÉCURITÉ DE LA HOTTE DE CUISINIÈRE 17 EXIGENCES D INSTALLATION 19 Outils et pièces 19 Exigences d emplacement 19 Exigences concernant l évacuation 20 Spécifications électriques 22 INSTRUCTIONS D INSTALLATION 22 Préparation de l emplacement 22 Installation de la hotte 23 Raccordement du circuit d évacuation 23 Raccordement électrique ...

Страница 3: ...e instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the wo...

Страница 4: ...zardous or explosive materials and vapors CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls or ceilings attics or into crawl spaces or garages WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE Never leave surface units unattended at high settings Boil...

Страница 5: ...chnician install the range hood It is the installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located behind the filter on the rear wall of the vent hood Canopy hood location should be away from strong draft areas such as windows doors and strong heating vents Cabinet opening dimensions that are shown must be...

Страница 6: ...seal exterior wall or roof opening around the cap The size of the vent should be uniform Cold Weather Installations An additional back draft damper should be installed to minimize backward cold air flow and a thermal break should be installed to minimize conduction of outside temperatures as part of the vent system The damper should be on the cold air side of the thermal break The break should be ...

Страница 7: ... MA 02169 7471 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 A 120 volt 60 Hz AC only 15 amp fused electrical circuit is required If the house has aluminum wiring follow the procedure below 1 Connect a section of solid copper wire to the pigtail leads 2 Connect the aluminum wiring to the added section of copper wire using special connectors and or tools designed and UL l...

Страница 8: ... the screw head to slide range hood into place Vent Cover Support Bracket Installation Installations using telescoping upper and lower vent cover assembly 1 Position vent cover bracket on wall about 3 0 mm away from the ceiling 2 Mark the hole locations 3 Drill 9 5 mm holes for wall anchors and insert anchors flush with the wall 4 Attach vent cover support bracket to wall Complete Preparation 1 De...

Страница 9: ...tions only 1 Assemble the air deflector with the duct cover bracket with 2 assembly screws provided with the Recirculation Kit 2 Measure from the bottom of the air deflector to the bottom of the hood outlet 3 Cut the duct to the measured size X 4 Remove the air deflector 5 Slide the duct onto the bottom of the air deflector 6 Place the assembled air deflector and duct over the exhaust outlet from ...

Страница 10: ... be reversed to hide slots CompleteInstallation 1 For non vented recirculating installations only install charcoal filters over the grease filters using the clips provided in the kit See the Range Hood Care section 2 Install metal filters See the Range Hood Care section 3 Check the operation of the range hood blower and light See the Range Hood Use section NOTE To get the most efficient use from y...

Страница 11: ...On Off light button controls both lights Press once for On and again for Off Operating the blower The BLOWER SPEED buttons turn the blower on and control the blower speed and sound level for quiet operation The speed can be changed anytime during fan operation by pressing the desired blower speed button Press the BLOWER OFF button a second time to turn the blower off A Grease filter B Grease filte...

Страница 12: ... to 6 months with normal use Replace with Charcoal Filter Kit See the Assistance or Service section for information on ordering To replace charcoal filter 1 Remove metal grease filter from range hood See Metal Grease Filter in this section 2 Bend spring clips away from metal grease filter 3 Place charcoal filter into top side of metal filter 4 Bend spring clips back into place to secure the charco...

Страница 13: ... Voltage Minimum Voltage Common Y G Y G Y GY BK W R BU Motor Characteristics Power Supply Frequency Power Absorption 240 Watts 120 VAC 60 Hz Motor Resistance Ohms Blue Black Blue Gray Blue Red Blue White Room Temp 28 8 10 30 3 10 37 7 10 45 1 10 73 4 F 23 C Motor Chassis Switch Operation POSITION FUNCTION Off Lamps Low Speed Medium Speed High Speed No Connection Brown Gray L 1 Brown Yellow L 2 Bro...

Страница 14: ...rea you can also look in your telephone directory Yellow Pages For further assistance If you need further assistance you can write to Whirlpool Corporation with any questions or concerns at Whirlpool Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor MI 49022 2692 Please include a daytime phone number in your correspondence InCanada Call the Whirlpool Canada LP Customer...

Страница 15: ...ice by an authorized Whirlpool servicer is not available 10 The removal and reinstallation of your major appliance if it is installed in an inaccessible location or is not installed in accordance with published installation instructions 11 Major appliances with original model serial numbers that have been removed altered or cannot be easily determined This warranty is void if the factory applied s...

Страница 16: ...16 Notes ...

Страница 17: ...as de non respect des instructions Votre sécurité et celle des autres est très importante Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager Assurez vous de toujours lire tous les messages de sécurité et de vous y conformer AVERTISSEMENT DANGER Voici le symbole d alerte de sécurité Ce symbole d alerte de sécurité vous signale les dangers potentiel...

Страница 18: ...die et évacuer adéquatement les gaz veiller à acheminer l air aspiré par un conduit jusqu à l extérieur ne pas décharger l air aspiré dans un espace vide du bâtiment comme une cavité murale un plafond un grenier un vide sanitaire ou un garage AVERTISSEMENT POUR RÉDUIRE LE RISQUE D INCENDIE UTILISER UNIQUEMENT DES CONDUITS MÉTALLIQUES AVERTISSEMENT POUR MINIMISER LE RISQUE D UN FEU DE GRAISSE SUR L...

Страница 19: ...ateur T10 Torx Exigencesd emplacement IMPORTANT Observer les dispositions de tous les codes et règlements en vigueur Confier l installation de la hotte à un technicien qualifié C est à l installateur qu incombe la responsabilité de respecter les distances de séparation spécifiées sur la plaque signalétique de l appareil La plaque signalétique de l appareil est située derrière le filtre sur la paro...

Страница 20: ... est recommandé Ne pas utiliser de conduit de plastique ou en aluminium La longueur du circuit d évacuation et le nombre de coudes doivent être réduits au minimum pour fournir une bonne performance Pour un fonctionnement efficace et silencieux Ne pas utiliser plus de trois coudes à 90 Veiller à ce qu il y ait une section droite de conduit de 24 61 0 cm ou plus entre deux coudes si on doit utiliser...

Страница 21: ...ce qui réduit considérablement la performance La sortie à l extérieur du circuit d évacuation peut se faire à travers le toit ou à travers un mur Pour la sortie à travers un mur on doit employer un raccord coudé 90 Décharge par l arrière Le raccord coudé à 90 peut être installé immédiatement au dessus de la hotte Installations sans décharge à l extérieur recyclage S il n est pas possible d évacuer...

Страница 22: ...e 1 et C22 2 n 0 M91 dernière édition et de tous les codes et règlements en vigueur INSTRUCTIONS D INSTALLATION Préparationdel emplacement Il est recommandé d installer le circuit d évacuation avant de procéder à l installation de la hotte Avant d exécuter les découpages vérifier la disponibilité d un dégagement suffisant dans le plafond ou le mur pour le conduit d évacuation Avant de sélectionner...

Страница 23: ...eminer le câble d alimentation du domicile selon les prescriptions du Code national de l électricité des normes CSA et des codes et règlements locaux Il faut que la longueur du conduit de et des conducteurs soit suffisante depuis le tableau de distribution avec fusibles ou disjoncteurs pour réaliser le raccordement dans le boîtier de connexion de la hotte REMARQUE Ne pas remettre le système sous t...

Страница 24: ...nnexion 3 Ôter l opercule arrachable du boîtier de connexion et installer un serre câble de homologation UL ou CSA 4 Acheminer le cordon d alimentation du domicile à travers le serre câble de jusque dans le boîtier de connexion 5 Connecter ensemble les conducteurs blancs B à l aide de connecteurs de fils homologation UL A Bride de cache conduit B Vis de 2 9 x 6 5 mm C Déflecteur A Déflecteur d air...

Страница 25: ...he conduit supérieur peut être inversé pour dissimuler les fentes Acheverl installation 1 Pour les installations sans décharge à l extérieur recyclage uniquement installer les filtres à charbon sur les filtres à graisse à l aide des attaches fournies avec l ensemble Voir la section Entretien de la hotte 2 Installer les filtres métalliques Voir la section Entretien de la hotte 3 Contrôler le foncti...

Страница 26: ...r une fois pour On marche et une deuxième fois pour Off arrêt Utilisation du ventilateur Les boutons BLOWER SPEED vitesse du ventilateur activent le ventilateur et contrôlent la vitesse du ventilateur et le niveau sonore pour un fonctionnement silencieux On peut modifier la vitesse à tout moment pendant le fonctionnement du ventilateur en appuyant sur le bouton de vitesse du ventilateur souhaité A...

Страница 27: ...harbon Voir la section Assistance ou service pour plus d informations sur le processus de commande Remplacement du filtre à charbon 1 Retirer le filtre à graisse métallique de la hotte Voir Filtre à graisse métallique dans cette section 2 Déplier les attaches à ressort pour les écarter du filtre à graisse métallique 3 Placer le filtre à charbon dans la partie supérieure du filtre métallique 4 Repl...

Страница 28: ...mum Commun JA VE JA VE JA GRIS N BL R BU Châssis à moteur BU BL JA JA MAR JA Caractéristiques du moteur Alimentation électrique Fréquence Absorption de courant 240 Watts 120 VAC 60 Hz Résistance du moteur ohms Bleu Noir Bleu Gris Bleu Rouge Bleu Blanc Temp ambiante 28 8 10 30 3 10 37 7 10 45 1 10 73 4 F 23 C Commutateur de fonctionnement POSITION FONCTION Arrêt Lampes Vitesse Basse Vitesse Moyenne...

Страница 29: ...ménagers Consignes d utilisation et d entretien Ventes d accessoires et de pièces de rechange Références aux marchands locaux aux distributeurs de pièces de rechange et aux compagnies de service Les techniciens de service désignés par Whirlpool Canada LP sont formés pour remplir la garantie des produits et fournir un service après la garantie partout au Canada Pour plus d assistance Si vous avez b...

Страница 30: ...en Whirlpool autorisé n est pas disponible 10 La dépose et la réinstallation de votre gros appareil si celui ci est installé dans un endroit inaccessible ou n est pas installé conformément aux instructions d installation fournies 11 Les gros appareils ménagers dont les numéros de série et de modèle originaux ont été enlevés modifiés ou qui ne peuvent pas être facilement identifiés La présente gara...

Страница 31: ...31 Notes ...

Страница 32: ...W10526057B 2012 Whirlpool Corporation All rights reserved Used under license in Canada Tous droits réservés Utilisée sous licence au Canada 11 12 Printed in Mexico Imprimé au Mexique ...

Отзывы: