12.

Remove the screw
holding the terminal
box cover. Remove
cover.

Panel C

OV R30/36"

HOOD

Numbers correspond
to steps.

10. 10a.

11. 11a.

13. 13a.

16. 16a.

12. 12a.

17. 17a.

18. 18a.

7. 8. 9.

5.

To vent through the roof with 
3-1/4" x 10" rectangular vent, 

mark

a line 1" and 5" from the back wall on the
underside of the cabinet. Mark lines  5-1/4"
to the right and left of the centerline on the
underside of cabinet that connect the lines
just drawn. Use a keyhole saw or saber saw
to cut a rectangular opening for the vent
system. Repeat for the underside of the top
of the cabinet.

To vent through wall with 3-1/4" x 10"
rectangular vent,

measure 1/8" and 

3-5/8" down from underside of cabinet and
mark on back wall. Measure and mark a
line 5-1/4" to right and left of centerline,
connecting the two lines. Use a keyhole saw
or saber saw to cut a rectangular opening
for the vent system.

To vent through the roof with round vent,

a

3-1/4" x 10" to round transition piece 

must

be used.

6.

Install vent system through the 
vent opening in upper cabinet or

wall. Complete venting system according
to method needed.  See Venting
requirements. Use caulking to seal exterior
wall or roof opening.

cabinet cutouts

1"

5-1/4"

5-1/4"

5"

7.

Set range hood on protective 
cover. Insert finger into hole in filter

and pull back and down to remove.
Repeat for other filter.

8.

Remove three screws that 
hold light cover panel in place.

Remove light panel and set aside.

9.

Carefully disconnect blower wiring 
connector from terminal box

connector plug. Snap blower wire retainer
out of blower housing.  Carefully set blower
on protective covering.  

Note: It is much easier to remove the vent
knockouts and to install the range hood
with the blower removed.

holes

filters

screws

wire
retainer

wire retainer
indents

blower wiring
connector plug

remove

screw

10.

Remove the roof vent 

knockout.  Remove top or rear

wiring knockout as needed.

damper blade
(remove if roof cap
has damper blade)

Venting through 
the roof

roof vent
knockout

wiring knockout

wiring knockout

11.

Attach exhaust vent 
connection to range hood.

Check that the damper blade rotates up
and down freely, if used.

14.

Do Not turn on power until 
installation is complete. 

Run

wiring through wall or cabinet according to
the National Electrical Code and local
codes and ordinances. 

13.

Lift the range hood into final position and
center. Mark on the underside of cabinet
the location of the four keyhole mounting
slots and the wiring knockout. On some
cabinets, filler blocks may need to be
added for range hood to attach to cabinet.
Set range hood aside on a protected
surface. 

keyhole slot

keyhole slot
outline

screw

15.

Start screws into neck area of 
each of the four keyhole

mounting screw slots marked on the
cabinet bottom.

16 .

Lift range hood into position, 
and feed electrical wire

through wiring opening. Position the range
hood so that the large end of the keyhole
slots are over the screws. Then push the
range hood toward the wall so that the
screws are in the neck of the keyhole slots.
Tighten mounting screws to cabinet,
making sure mounting screws are in narrow
neck of slots. Make sure that damper blade
rotates up and down freely.

Excessive Weight Hazard

Use two or more people to move and
install range hood.

Failure to follow this instruction can
result in back or other injury.

WARNING

17.

Reinstall blower back into 
position. Snap blower wire

retainer back into blower housing indents.
Reconnect the blower wiring connector
back into the terminal box connector plug. 

terminal box 

3"

5"

Содержание RH8330 SERIES

Страница 1: ...ool Consumer Assistance Center will answer any questions about operating or maintaining your range hood not covered in the Installation Instructions The Whirlpool Consumer Assistance Center is open 24 hours a day 7 days a week Just dial 1 800 253 1301 the call is free If you need service In the event your Whirlpool appliance should need service call the dealer from whom you purchased the appliance...

Страница 2: ...s operation Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society of Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must...

Страница 3: ... of at least 66 square inches If longer vent system is required the shortest possible ventwork length should be used to ensure the maximum CFM of air movement for best venting A transition to round must be used as close to the hood as possible to eliminate the restriction caused by 3 1 4 x 10 vent 45 elbows should be used instead of 90 elbows wherever possible A roof cap providing a free area of 1...

Страница 4: ...nstall the range hood with the blower removed holes filters screws wire retainer wire retainer indents blower wiring connector plug remove screw 10 Remove the roof vent knockout Remove top or rear wiring knockout as needed damper blade remove if roof cap has damper blade Venting through the roof roof vent knockout wiring knockout wiring knockout 1 1 Attach exhaust vent connection to range hood Che...

Страница 5: ...Not turn on power until installation is complete Run wiring through wall or cabinet according to the National Electrical Code and local codes and ordinances 13a Lift the range hood into final position and center Mark on the underside of cabinet the location of the four keyhole mounting slots and the wiring knockout On some cabinets filler blocks may need to be added for range hood to attach to cab...

Страница 6: ...th and grease cutting detergent Exterior surfaces Clean the range hood with a mild detergent and soft cloth Do Not use abrasive cleaners or steel wool Light Do Not use bulbs larger than 60 watts in light sockets To replace bulbs Remove three screws that hold light cover panel in place Remove panel and set aside Replace bulb Replace light cover panel before operating fan or light Light bulbs are no...

Страница 7: ... parts such as light bulbs and filters C Service calls to 1 Correct the installation of the range hood 2 Instruct you how to use the range hood 3 Replace house fuses or correct house wiring D Repairs when range hood is used in other than normal single family household use E Pickup and delivery This product is designed to be repaired in the home F Damage to range hood caused by accident misuse fire...

Отзывы: