5-5
Refer to page 4-2 for the procedure for servic-
ing a single element infinite switch.
NOTE: Refer to the Tech Sheet Wiring Dia-
gram that is supplied with the unit to determine
the wiring for the infinite switch you are servic-
ing.
1.
Unplug the refrigerated range or discon-
nect the power.
2.
Set the ohmmeter to the R x 1 scale.
3.
Turn the appropriate infinite switch to the
On position.
4.
Touch the ohmmeter test leads to termi-
nals L1 and P. The meter should indicate
continuity (0
Ω
).
5.
Touch the ohmmeter test leads to termi-
nals L1 and H1. The meter should indicate
continuity (0
Ω
).
6.
Touch the ohmmeter test leads to termi-
nals L2 and H2. The meter should indicate
continuity (0
Ω
).
SINGLE ELEMENT INFINITE
SWITCHES (RF, RR, & LR)
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
L2
L1
H1
H2
P
P
H1
L1
L2
H2
BIMETALS (N.C.)
Refer to page 4-33 for the procedure for servic-
ing the bimetals.
1.
Unplug the refrigerated range or discon-
nect the power.
2.
Set the ohmmeter to the R x 1 scale.
3.
Touch the ohmmeter leads to the bimetal
connector pins. The meter should indicate
a closed circuit (0
Ω
). If the reading indi-
cates an open (infinite) circuit, replace the
bimetals.
IMPORTANT:
The bimetal marked (F36-18F)
must be mounted
below
the other bimetal. The
bimetals will be replaced as an assembly.
Lower Bimetal (F36-18F)
Содержание Polara GR556LRK
Страница 1: ...CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS KR 33 JOB AID Part No 8178194 Model GR556LRK ...
Страница 12: ...1 8 NOTES ...
Страница 20: ...2 8 NOTES ...
Страница 24: ...3 4 NOTES ...
Страница 72: ...5 12 NOTES ...
Страница 76: ...6 4 NOTES ...
Страница 78: ...7 2 STRIP CIRCUITS CONTROL PANEL CLOCK ON CONTROL PANEL COOLING FAN MOTOR OVEN LIGHT BROIL ...
Страница 79: ...7 3 BAKE CONVECTION BAKE ACCUSIMMER ...
Страница 85: ...8 5 NOTES ...
Страница 86: ...8 6 NOTES ...
Страница 88: ...CORPORATION ...