MISTING MODE: Air Damper Open—
Air Flows Through Vents Only
During the misting cycle, the compressor pro-
duces the Presiva mixture, and a fan creates
a draft at the top of the cabinet to vent the used
mixture. At the end of the misting cycle, the
compressor turns off, and a heater is ener-
gized, along with the fan, to dry the fabric.
The Heater has dual elements that are wired
in parallel. One element is rated at 440 Watts,
and the other element at 880 Watts. The ele-
ments can be operated together, or indepen-
dently, depending on the cycle that is selected.
A thermostat is located in the heater compart-
ment to guard against overheating (see the
photos below). A thermistor monitors the air
temperature as it exits the cabinet (see the
above photo for the thermistor location).
DRYING MODE: Air Damper Closed—
Air Flows Through Heater Into Cabinet
During the “drying” mode, the wax motor is
energized, which closes the air damper, and
directs air through the heater and into the cabi-
net.
Air Damper
Open
Wax Motor
Air Flow
Vent
In
Vent
Out
Low Pressure Area
An air damper, located in the upper compart-
ment air chamber, directs the air flow between
misting and drying modes. A wax motor con-
trols the position of the air damper.
During the “misting” mode, the wax motor is
de-energized. This opens the air damper and
directs air to create the low pressure area
above the interior vent.
Vent
Air
Flow
Vent
In
Vent
Out
Heater
Air Damper
Closed
Thermistor
Heater
Elements
Thermostat
Air In
Air Out