SAFETY INSTRUCTIONS

Explanation of symbols displayed unit.

WARNING

This symbol shows that this appliance uses a flammable 

refrigerant.

If the refrigerant is leaked and exposed to an external ignition 

source, there is a risk of fire

CAUTION

This symbol shows that the operation manual should be read 

carefully

CAUTION

This symbol shows that a service personnel should be handling 

this equipment with reference to the installation manual

CAUTION

This symbol shows that information is available such as the 

operating manual or installation manual

SAFETY INSTRUCTIONS FOR SERVICING APPLIANCE WITH SPESIFIC REFRIGERANT

•  Download the complete manual for detailed installation, servicing, maintenance and 

reparing methods on docs.whirlpool.eu.

• 

  Do not use means to accelerate the defrosting process or to clean, other than those 

recommended by the manufacturer.

• 

  The appliance shall be stored in a well-ventilated area where the room size 

corresponds to the room area as specified for operation; without continuously 

operating ignition sources (such as; open flames, an operating gas appliance or an 

operating electric heater).

• 

  Do not pierce or burn. Be aware that the refrigerants may not contain an odor.  

Any person who is involved with working on or breaking into a refrigerant circuit 

should hold a current valid certificate from an industry-accredited assessment 

authority, which authorizes their competence to handle refrigerants safely in 

accordance with an industry recognized assessment specification. Servicing shall only 

be performed as recommended by the equipment manufacturer. Maintenance and 

repair requiring the assisstance of other skilled personnel shall be carried out under the 

supervision of the person competent in the use of flammable refrigerants. Appliance 

shall be installed, operated and stored in a room with a floor area larger than 11 m

2

. The 

installation of pipe-work shall be kept to a room with a floor area larger than 11 m

2

. The 

pipe-work shall be compliance with national gas regulations. The maximum refrigerant 

charge amount is 0.22 kg.  

When flared joints are reused , the flare part shall be re fabricated.

1.   Transport of equipment containing flammable refrigerants shall be compliant with the 

transport regulations.

2.  Marking of equipment using signs shall be compliant with local regulations.

3.   Disposal of equipment using flammable refrigerants shall be compliant with national 

regulations.

Содержание PACHW2900CO

Страница 1: ...Instructions for use ...

Страница 2: ......

Страница 3: ... 3 PACHW2900CO ENGLISH Instructions for use Page 4 ...

Страница 4: ...ppliance unless continuously supervised Children from 8years old and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge can use this appliance only if they are supervised or have been given instructions on safe use and understand the hazards involved Children must not play with the appliance Cleaning and user maintenance must not be carried o...

Страница 5: ...he event of problems contact the dealer or your nearest After sales Service Once installed packaging waste plastic styrofoam parts etc must be stored out of reach of children risk of suffocation The appliance must be disconnected from all remote power supply before any installation operation risk of electric shock During installation make sure the appliance does not damage the power cable risk of ...

Страница 6: ...rdance with national wiring regulations Model 9K Required capacity of circuit breaker 16A Fuse Type T3 15A 250VAC CLEANING AND MAINTENANCE WARNING Ensure that the appliance is switched off and disconnected from the power supply before performing any maintenance operation never use steam cleaning equipment risk of electric shock DISPOSAL OF PACKAGING MATERIALS The packaging material is 100 recyclab...

Страница 7: ...ic heater Do not pierce or burn Be aware that the refrigerants may not contain an odor Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry accredited assessment authority which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification Servicing s...

Страница 8: ...e atmospheres Ensure that hte leak detection equipment being used is suitable for use with flammable refrigerants i e non sparking adequately sealed or intrinsically safe 6 5 Presence of fire extinguisher If any hot work is to be conducted on the refrigerating equipment or any associated partsappropriate fire extinguishing equipment shall be avalaible to hand Have a dry powder or CO2 fire extingui...

Страница 9: ...lt with if the fault cannot be corrected immediately but it is necessary to continue operation an adequate temporary solution shall be used This shall be reported to the owner of the equipment so all parts are advised Initial safety checks shall include That capacitors are discharged this shall be done in a safe manner to avoid possibility of sparking That there no live electrical components and w...

Страница 10: ...nsitivity may not be adequate or may need re calibration Detection equipment shall be calibrated in a refrigerant free area Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of ga...

Страница 11: ...ith OFN The system shall be leak tested on completion of charging but prior to commissioning A follow up leak test shall be carried out prior to leaving the site 13 Decommissioning Before carrying out this procedure it is essential that the technician is completely familiar with the equipment and all its detail It is recommended good practice that all refrigerants are recovered safely Prior to the...

Страница 12: ...free disconnect couplings and in good condition Before using the recovery machine check that it is in satisfactory working order has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release Consult manufacturer if in doubt The recovered refrigerant shall be returned to the refrigerant supplier in the correct recover...

Страница 13: ... before restarting If a button is pressed during this time the compressor will not restart for another 3 to 5 minutes In Cooling or Dry mode the compressor and condenser fan will stop when the room temperature reaches the set temperature In Fan Only mode the temperature can NOT be set Below operation modes can only be set by remote controller In the event of a power failure your air conditioner wi...

Страница 14: ...replaced in the remote controller the remote controller pre set at Heat Pump mode The heat pump AC remote controller can be used to control the cool only AC models The remote control will operate the air conditioner at a distance of up to 7m Use RC to control the appliance To operate the appliance by remote control point the remote control at the receiving device on the indoor unit to ensure recei...

Страница 15: ...l Around U function When you press this button remote control transmits the actual room temperature around it to the indoor unit and the appliance will operate according this temperature to let you feel more comfortable 10 TIMER BUTTON Used to set or cancel the timer on operation Used to set or cancel the timer off operation With the product turned off consumer must select the Mode Fan speed and t...

Страница 16: ...ely before replacing to ensure maximum efficiency 6 Reattach the air filter to the filter panel door 7 Reinstall filter panel door 8 Press ON OFF to start the air conditioner Cleaning the Outside 1 Unplug air conditioner or disconnect from power 2 Remove the air filter and clean separately See Cleaning the Air Filter 3 Wipe outside of the air conditioner with a soft damp cloth 4 Plug in air condit...

Страница 17: ...window exhaust adapter into the flexible exhaust hose both the coupling and window exhaust adapter have integrai clips that snap onto the hose 3 lnsert the coupling into the slot on the back of the air conditioner 4 Slide down to lock the hose into place 5 Confirm the hose is locked in place before operating coupling flexible exhaust hose windows exhaust adapter exhaust hose assembly A A Flexible ...

Страница 18: ...dow Kit are available online and are compatible with any window and sliding doors in aluminun wood and PVC Electrical Requirements The local air conditioner should be connected to a 220 240V 50Hz 20 amp fused grounded outlet The use of a time delay fuse or time delay circuit breaker is recommended All wiring must comply with local and national electrical regulations and be installed by a qualified...

Страница 19: ...n a room A higher capacity air conditioner may be required depending on the size of the room being cooled Air conditioner runs for a short time only but room is not cool or hot Set temperature is close to room temperature Lower or Higher set temperature See Operating mode description Display error code If the unit display error code E5 it is water full in the unit you should drain the water see Dr...

Страница 20: ... Service on service sticker which is located on the side or on the bottom of the indoor unit The service number can also be found in the warranty booklet your full address your telephone number If repair work has to be carried out contact the Customer Care Centre Use of original spare parts and a proper repair is guarenteed You will need to present the original invoice Failure to comply with these...

Отзывы: