6
I
NSTALLATION
I
NSTRUCTIONS
Shipped ready for ventless (recirculating) operation,
converts to top or rear discharge.
66
1
⁄
4
" min.
mounting
height from
floor
A
B
66
1
⁄
4
" min.
mounting
height from
floor
30" min.
width required
Exhaust outlet
connects to
3
1
⁄
4
"x10"
duct
23
1
⁄
16
"
door open
15
3
⁄
8
"
16
1
⁄
4
"
30"
13"
NOTE:
There must be at least one wall stud within
cabinet opening.
Check the opening where the microwave
oven hood will be installed. The location must
provide:
•
2 inch x 4 inch wood studding and
3
⁄
8
inch
thickness drywall or plaster lath
•
Support for microwave oven hood weight of
150 pounds plus the weight of items placed in
the oven or upper cabinet
•
30 inch wide minimum opening
•
14 inch clearance between the bottom of micro-
wave oven hood and the cooktop
•
Protection from draft areas, such as windows,
doors, and strong heating vents
•
Grounded electrical outlet (see “Electrical
requirements” in the “Microwave Oven Safety”
section)
30
1
⁄
4
" min. from cooking surface
(or countertop) below microwave oven
to top of wall mounting bracket
14" min. to cooking surface
(or countertop) below microwave oven
CRITICAL DIMENSIONS
A
B
S
PACE
REQUIREMENTS