18
Natural Gas Orifice Spud Chart
5. Replace the LP gas orifice spud with correct Natural gas
orifice spud. See the “Natural Gas Orifice Spud Chart.”
6. Replace burner base and hand tighten the screws.
7. Replace burner cap.
8. Repeat steps 1 through 7 for the remaining burners.
9. Place LP gas orifice spuds in plastic parts bag for future use
and keep with literature package.
10. Replace burner grates.
11. Complete installation. See “Make Gas Connection” and
“Electronic Ignition System” sections.
Checking for proper cooktop burner flame is very important.
The small inner cone should have a very distinct blue flame
¼" to ½" long. The outer cone is not as distinct as the inner
cone. Natural gas flames do not have yellow tips.
IMPORTANT: You may have to adjust the “LO” setting for
each cooktop burner. See “Adjust Flame Height” in the
“Electronic Ignition System” section.
Burner Rating
Color
Number
5,000 BTU
Green
107N
7,300 BTU
Yellow
125N
9,200 BTU
Orange
142N
10,000 BTU
Clear
149N
15,000 BTU
White
180N
16,000 BTU
Black
195N