If you are using power supply cord, a grounded electrical 

 

outlet located within 2 ft. (610 mm) of either side of dryer.  

See “Electrical Requirements.”
A sturdy floor to support the total weight (dryer and load) 

 

of 200 lbs. (90.7 kg). The combined weight of a companion 

appliance should also be considered.
Level floor with maximum slope of 1" (25 mm) under entire 

 

dryer. (If slope is greater than 1" [25 mm], install Extended  

Dryer Feet Kit, Part Number 279810.) If not level, clothes  

may not tumble properly and automatic sensor cycles may  

not operate correctly.

Do not operate your dryer at temperatures below 45°F (7°C). At 

lower temperatures, the dryer might not shut off at the end of an 

automatic cycle. Drying times can be extended.

The dryer must not be installed or stored in an area where it will 

be exposed to water and/or weather.

Check code requirements. Some codes limit, or do not permit, 

installation of the dryer in garages, closets, mobile homes, or 

sleeping quarters. Contact your local building inspector.

Installation clearances:

The location must be large enough to allow the dryer door  

to open fully.

 

Dryer Dimensions

43"

(1092 mm)

*29

1

/

2

"

(749 mm)

27"

(687 mm)

A

23¾"

(603 mm)

43"

(1092 mm)

27"

(687 mm)

*29

1

/

2

"

(749 mm)

13¾"

(349 mm)

B

A. Large opening side-swing door

B. Wide opening hamper door

*Most installations require a minimum 5½" (140 mm) clearance   

 behind the dryer for the exhaust vent with elbow. See “Venting  

 Requirements.”

minimum spacing for recessed area or  

closet installation

The dimensions shown following are for the minimum spacing 

allowed.

Additional spacing should be considered for ease of 

 

installation and servicing.
Additional clearances might be required for wall, door, and 

 

floor moldings.
Additional spacing of 1" (25 mm) on all sides of the dryer is 

 

recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation 

 

openings in the top and bottom of the door are required.  

Louvered doors with equivalent ventilation openings  

are acceptable.
Companion appliance spacing should also be considered.

 

minimum Required Spacing

 

A

B

C

    18"*

(457 mm)

  1"

(25 mm)

27"

(686 mm)

        1"

   (25 mm)

        1"*

    (25 mm)

14" max.*

(356  mm)

 

  29

¼"

(743 mm)

   

5

½"*

 (140 mm)

  48 in.

  

(310 cm )

2

*

2

  

24 in.

(155 cm )

*

2

       

3"*

(76 mm)

       

3"*

(76 mm)

A. Recessed area

B. Side view – closet or confined area

C. Closet door with vents

*Additional spacing recommended

mobile home - Additional installation requirements

This dryer is suitable for mobile home installations. The 

installation must conform to the Manufactured Home 

Construction and Safety Standard, Title 24 CFR, Part 3280 

(formerly the Federal Standard for Mobile Home Construction  

and Safety, Title 24, HUD Part 280).

Metal exhaust system hardware, which is available for 

 

purchase from your dealer.
Special provisions must be made in mobile homes to 

 

introduce outside air into the dryer. The opening (such  

as a nearby window) should be at least twice as large  

as the dryer exhaust opening.

Electrical Requirements

It is your responsibility:

To contact a qualified electrical installer.

 

To be sure that the electrical connection is adequate and in 

 

conformance with the National Electrical Code, ANSI/NFPA 

70-latest edition and all local codes and ordinances. 

 

The National Electrical Code requires a 4-wire power supply 

connection for homes built after 1996, dryer circuits involved 

in remodeling after 1996, and all mobile home installations. 

 

A copy of the above code standards can be obtained from: 

National Fire Protection Association, One Batterymarch Park, 

Quincy, MA 02269.
To supply the required 3 or 4 wire, single phase, 120/240 volt, 

 

60 Hz, AC only electrical supply (or 3 or 4 wire, 120/208 volt 

electrical supply, if specified on the serial/rating plate) on a 

separate 30-amp circuit, fused on both sides of the line. A 

time-delay fuse or circuit breaker is recommended. Connect 

to an individual branch circuit. Do not have a fuse in the 

neutral or grounding circuit.
Do not use an extension cord.

 

If codes permit and a separate ground wire is used, it is 

 

recommended that a qualified electrician determine that the 

ground path is adequate.

Содержание MEDX700XL

Страница 1: ... System 15 Connect Vent 15 Level Dryer 16 Complete Installation Checklist 16 DOOR REVERSAL 17 Troubleshooting 20 Electric Dryer Installation Instructions 27 Wide Models U S A Only Para obtener acceso al manual de uso y cuidado en español o para obtener información adicional acerca de su producto visite www whirlpool com Tenga listo su número de modelo completo Puede encontrar el número de modelo y...

Страница 2: ...2 DRYER SAFETY ...

Страница 3: ...rical Requirements and Venting Requirements before purchasing parts Mobile home installations require metal exhaust system hardware available for purchase from the dealer from whom you purchased your dryer For further information please reference the Assistance or Service section of the Dryer User Instructions If using a power supply cord Use a UL listed power supply cord kit marked for use with c...

Страница 4: ...d doors with equivalent ventilation openings are acceptable Companion appliance spacing should also be considered Minimum Required Spacing A B C 18 457 mm 1 25mm 27 686mm 1 25mm 1 25mm 14 max 356 mm 29 743mm 5 140mm 48in 310cm 2 2 24in 155cm 2 2 3 76mm 3 76mm A Recessed area B Side view closet or confined area C Closet door with vents Additional spacing recommended Mobile home Additional installat...

Страница 5: ...se a UL listed power supply cord kit marked for use with clothes dryers The kit should contain A UL listed 30 amp power supply cord rated 120 240 volt minimum The cord should be type SRD or SRDT and be at least 4 ft 1 22 m long The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends A UL listed strain relief If your outlet looks like this If your outlet...

Страница 6: ...le panel and gently lay dryer down on cardboard Screw in leveling legs 2 diamond marking Examine leveling legs find diamond marking Screw legs into leg holes by hand Use a wrench to finish turning legs until diamond marking is no longer visible Now stand the dryer on its feet Slide the dryer until it is close to its final location Leave enough room for electrical connection and to connect the exha...

Страница 7: ...rements Power supply cord 3 wire receptacle NEMA Type 10 30R Go to 3 wire Power Supply Cord Connection section Then go to Venting Requirements NOTE If local codes do not permit connection of a cabinet ground conductor to neutral wire go to Optional 3 wire Connection section This connection may be used with either a power supply cord or a direct wire connection E F D C B A 2 Remove terminal block c...

Страница 8: ...r 1 Power supply cord strain relief 4 wire Power Supply Cord Connection Remove center terminal block screw B Remove neutral ground wire E from external ground conductor screw A A E B Prepare to connect neutral ground wire and neutral wire 1 B C E Connect neutral ground wire and neutral wire 2 Connect neutral ground wire E and neutral wire white or center C of power supply cord under center termina...

Страница 9: ...s to outer terminal block screws Tighten screws Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements 2 Connect neutral wire Connect neutral wire white or center C of power supply cord to center terminal block screw B Tighten screw C B Remove center terminal block screw B B 1 Remove center screw A F Connect groun...

Страница 10: ...reads A B C 1 Attach direct wire strain relief Put direct wire cable through the strain relief The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position Tighten strain relief screw against the direct wire cable 2 Attach direct wire cable to strain relief Direct wire strain relief Direct wire cable must have 5 ft 1 52 m of extra length so dryer may be moved if...

Страница 11: ... slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements 5 Connect remaining wires B E C 3 Connect neutral ground wire and neutral wire Connect neutral ground wire E and place hooked end hook facing right of neutral wire white or center wire C of direct wire cable under center screw of terminal block B Squeeze hooked ends together and tighten screw Direct wire cab...

Страница 12: ...tor screw A to an adequate ground Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements Optional 3 wire Connection IMPORTANT You must verify with a qualified electrician that this grounding method is acceptable before connecting Connect remaining wires 4 Place hooked ends of remaining direct wire cable wires unde...

Страница 13: ... install in enclosed walls ceilings or floors The total length should not exceed 7 3 4 ft 2 4 m NOTE If using an existing vent system clean lint from entire length of the system and make sure exhaust hood is not plugged with lint Replace plastic or metal foil vents with rigid metal or flexible metal vents Review Vent System Chart and if necessary modify existing vent system to achieve best drying ...

Страница 14: ...stallation also available with one offset elbow Periscope installation NOTE The following kits for close clearance alternate installations are available for purchase Venting Kits For more information call 1 800 901 2042 or visit us at www applianceaccessories com In Canada call 1 800 807 6777 or visit us at www whirlpoolparts ca Part Number Descriptions 8171587RP 0 5 Metal vent periscope 4396037RP...

Страница 15: ...t material and hood combinations acceptable to use NOTE Do not use vent runs longer than those specified in Vent System Chart Exhaust systems longer than those specified will Shorten life of dryer Reduce performance resulting in longer drying times and increased energy usage NOTE Side and bottom exhaust installations have a 90º turn inside the dryer To determine maximum exhaust length add one 90º ...

Страница 16: ...at dryer is level See Level Dryer q Remove film on console and any tape remaining on dryer q Wipe dryer drum interior thoroughly with a damp cloth to remove any dust q Read Dryer Use in your Use and Care Guide q Set the dryer on a full heat cycle not an air cycle for 20 minutes and start the dryer If the dryer will not start check the following Controls are set in a running or On position Start bu...

Страница 17: ... door 6 Take outer door and rotate it 180º and set it back down on inner door Be certain to keep cardboard spacer centered between doors Reattach outer door panel to inner door panel so handle is on the side where hinges were just removed Insert 5 door screws Remove screws at top bottom and side of door 5 screws Keep door screws separate from hinge screws as they are different sizes Holding door o...

Страница 18: ...oor strike aligns with door catch If it is needed slide door catch left or right within slot to adjust alignment Insert screws in hinge holes on dryer cabinet 10 NOTE 2 people maybe needed to reinstall door Insert screws into the bottom holes on left side of dryer cabinet Tighten screws halfway Position door so large end of door hinge slot is over screws Slide door up so screws are in bottom of sl...

Страница 19: ... dryer door Remove bottom screws from dryer cabinet side of hinges Loosen do not remove top screws from dryer cabinet side of hinges Remove screws at top bottom and side of door 4 screws Keep door screws separate from hinge screws as they are different sizes Remove screws from door 6 Remove screws attaching hinges to door Remove screws from hinges 4 Flip door over 5 Flip door over so handle side i...

Страница 20: ...ews in hinge holes on dryer cabinet 12 NOTE 2 people maybe needed to reinstall door Insert screws into the bottom holes on left side of dryer cabinet Tighten screws halfway Position door so large end of door hinge slot is over screws Slide door up so screws are in bottom of slots Tighten screws Insert and tighten top screws in hinges Rotate outer door 8 Take outer door and rotate it 180º and set i...

Отзывы: