Must include a shutoff valve:

An individual shutoff valve must be installed within 

six (6) feet (1.8 m) of the washer/dryer in accordance with 

the National Fuel Gas Code, ANSI Z223.1/NFPA 54. The 

location should be easy to reach for opening and closing.

Burner input requirements:

Elevations up to 10,000 ft (3,048 m):

The design of this washer/dryer is certified by CSA 

International for use at altitudes up to 10,000 ft (3,048 m) 

above sea level at the Btu rating indicated on the model/serial 

number plate. Burner input adjustments are not required when 

the dryer is operated up to this elevation.

Elevations above 10,000 ft (3,048 m):

When installed above 10,000 ft (3,048 m), a 4% reduction of 

the burner Btu rating shown on the model/serial number plate 

is required for each 1,000 ft (305 m) increase in elevation.

Gas supply pressure testing

The washer/dryer must be disconnected from the gas supply 

piping system during pressure testing at pressures greater 

than ½ psi.

Dryer gas connection

This washer/dryer is equipped with its own permanent, 

flexible gas connector, design-certified by CSA International, 

for connecting the washer/dryer to the gas supply line.

Flexible gas connector

Venting Requirements

WARNING:

 

To reduce the risk of fire, this washer/dryer 

MUST BE EXHAUSTED OUTDOORS.

IMPORTANT:

 Observe all governing codes and ordinances.

The dryer exhaust must not be connected into any gas vent, 

chimney, wall, ceiling, attic, crawlspace, or a concealed space 

of a building.

If using an existing vent system

Clean lint from the entire length of the system and make sure 

exhaust hood is not plugged with lint. 
Replace any plastic or metal foil vent with rigid or flexible 

heavy metal vent.
Review Vent system chart. Modify existing vent system if 

necessary to achieve the best drying performance. Only rigid 

or flexible metal vent shall be used for exhausting. 

If this is a new vent system 

Vent material

Use a heavy metal vent. Do not use plastic or metal foil vent.
4" (102 mm) heavy metal exhaust vent and clamps must be 

used. DURASAFE™ venting products are recommended.

DURASAFE™ vent products can be purchased from your 

dealer or by calling Whirlpool Parts and Accessories. For more 

information, see the “Assistance or Service” section of the 

Washer/Dryer User Instructions.

Rigid metal vent

For best drying performance, rigid metal vents are 

recommended.
Rigid metal vent is recommended to avoid crushing and 

kinking.

Flexible metal vent

Flexible metal vents are acceptable only if accessible for 

cleaning.
Flexible metal vent must be fully extended and supported 

when the dryer is in its final location. 

A. Gas shutoff valve
B. " NPT minimum plugged tapping

C. ½" NPT gas supply line
D. Gas supply line coupling 34" (864 mm) min. 

to 37" (940 mm) max. from floor

A

B

C

D

4" (102 mm) heavy metal exhaust vent

WARNING

Fire Hazard

Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death 

or fire.

4"

102 mm

1

8

Содержание LTG5243DQ - 24" Twin Washer/Dryer Laundry Center

Страница 1: ...ed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages T...

Страница 2: ...ied or licensed by the State of Massachusetts If using a ball valve it shall be a T handle type A flexible gas connector when used must not exceed 3 feet IMPORTANT The gas installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 The dryer must be electrically grounded in accordance with local codes or in the absence of local co...

Страница 3: ...t operate your washer in temperatures at or below 32ºF 0ºC Some water can remain in the washer and can cause damage in low temperatures See Washer Dryer Care in the Washer Dryer User Instructions for winterizing information Do not operate your dryer at temperatures below 45 F 7 C At lower temperatures the dryer might not shut off at the end of an automatic cycle This can result in longer drying ti...

Страница 4: ...lation Kit Part Number 346764 See Tools and Parts section for information on ordering Special provisions must be made in mobile homes to introduce outside air into the dryer The opening such as a nearby window should be at least twice as large as the dryer exhaust opening DrainSystem The washer dryer can be installed using the standpipe drain system floor or wall the laundry tub drain system or th...

Страница 5: ...mpany Gas supply line Must include NPT minimum plugged tapping accessible for test gauge connection immediately upstream of the gas supply connection to the dryer see illustration IPS pipe is recommended approved aluminum or copper tubing is acceptable for lengths under 20 ft 6 1 m if local codes and gas supplier permit If you are using Natural gas do not use copper tubing Lengths over 20 ft 6 1 m...

Страница 6: ...into any gas vent chimney wall ceiling attic crawlspace or a concealed space of a building If using an existing vent system Clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint Replace any plastic or metal foil vent with rigid or flexible heavy metal vent Review Vent system chart Modify existing vent system if necessary to achieve the best drying perf...

Страница 7: ... 1 Push legs into holes in rear corners until they snap into place 2 Check adjustability of rear legs by pushing in one leg The other leg should come out Check both legs If they do not move freely repeat Step 1 Install the front leveling legs 1 Examine the front leveling legs Find the diamond marking 2 Screw front legs by hand into the holes in the triangular braces in the front corners Use wrench...

Страница 8: ... of drain hose into laundry tub or standpipe Rotate hook to eliminate kinks To keep drain water from going back into the washer Do not force excess drain hose into standpipe Hose should be secure but loose enough to provide a gap for air Do not lay excess hose on the bottom of the laundry tub For use with floor drain Do not install the drain hose form onto the corrugated drain hose You may need ad...

Страница 9: ...ts and check for leaks A small amount of water might enter the washer You will drain this water later NOTE Replace inlet hoses after 5 years of use to reduce the risk of hose failure Record hose installation or replacement dates for future reference If you connect only one water hose you must cap off the remaining water inlet port Periodically inspect and replace hoses if bulges kinks cuts wear or...

Страница 10: ...rt Number 4396014 29 737 mm to 50 1 27 m mismatch Special provisions for mobile home installations The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home Terminate the exhaust vent outside Determine vent path Select the route that will provide the straightest and most direct path outdoors Plan the installat...

Страница 11: ...e joint compound NOTE For LP gas connections you must use pipe joint compound resistant to the action of LP gas Do not use TEFLON tape 4 Attach the flexible gas connector to the NPT adapter Do not use pipe joint compound for this connection There should be a natural loop in the flexible gas connector The flexible gas connector must not be twisted kinked or attached with any sharp bends 5 All conne...

Страница 12: ...the Cycle Control knob Allow the washer to complete one whole cycle 13 To test the dryer set the dryer on a full heat cycle not an air cycle for 20 minutes and start the dryer If the dryer will not start check the following Washer dryer is plugged into a grounded 3 prong outlet Start button has been firmly pushed Electrical supply is connected Household fuses are intact and tight or circuit breake...

Отзывы: