Floor drain system (view D)

The floor drain system requires a siphon break that may be 

purchased separately. See “Alternate Parts.”
The siphon break must be a minimum of 28" (711 mm) from the 

bottom of the washer. Additional hoses might be needed.

Electrical Requirements

It is your responsibility

To contact a qualified electrical installer.
To be sure that the electrical connection is adequate and in 

conformance with the National Electrical Code, ANSI/NFPA 

70-latest edition and all local codes and ordinances. 
A copy of the above code standards can be obtained from: 

National Fire Protection Association, One Batterymarch Park, 

Quincy, MA 02269.
To supply the required 3 or 4 wire, single phase, 120/240 volt, 

60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt 

electrical supply, if specified on the serial/rating plate) on a 

separate 30-amp circuit, fused on both sides of the line. A 

time-delay fuse or circuit breaker is recommended. Connect 

to an individual branch circuit. Do not have a fuse in the 

neutral or grounding circuit. 
Do not use an extension cord.
If codes permit and a separate ground wire is used, it is 

recommended that a qualified electrician determine that the 

ground path is adequate.

Electrical Connection

To properly install your washer/dryer, you must determine the type 

of electrical connection you will be using and follow the 

instructions provided for it here.

This dryer is manufactured ready to install with a 3-wire 

electrical supply connection. The neutral ground wire is 

permanently connected to the neutral conductor (white wire) 

within the dryer. If the dryer is installed with a 4-wire electrical 

supply connection, the neutral ground wire must be removed 

from the internal ground connector (green screw), and secured 

under the neutral terminal (center or white wire) of the terminal 

block. When the neutral ground wire is secured under the 

neutral terminal (center or white wire) of the terminal block, the 

dryer cabinet is isolated from the neutral conductor.
If local codes do not permit the connection of a neutral ground 

wire to the neutral wire, see “Optional 3-wire connection” 

section. 
A 4-wire power supply connection must be used when the 

appliance is installed in a location where grounding through 

the neutral conductor is prohibited. Grounding through the 

neutral is prohibited for (1) new branch-circuit installations, 

(2) mobile homes, (3) recreational vehicles, and (4) areas 

where local codes prohibit grounding through the neutral 

conductors.

If using a power supply cord:
Use a UL listed power supply cord kit marked for use with clothes 

dryers. The kit should contain:

A UL listed 30-amp power supply cord, rated 120/240 volt 

minimum. The cord should be type SRD or SRDT and be at 

least 4 ft (1.22 m) long. The wires that connect to the dryer 

must end in ring terminals or spade terminals with upturned 

ends.
A UL listed strain relief.

If your outlet looks like this:

4-wire receptacle (14-30R)

Then choose a 4-wire power supply cord with ring or spade 

terminals and UL listed strain relief. The 4-wire power supply cord, 

at least 4 ft (1.22 m) long, must have four 10-gauge copper wires 

and match a 4-wire receptacle of NEMA Type 14-30R. The ground 

wire (ground conductor) may be either green or bare. The neutral 

conductor must be identified by a white cover.
If your outlet looks like this:

3-wire receptacle (10-30R)

Then choose a 3-wire power supply cord with ring or spade 

terminals and UL listed strain relief. The 3-wire power supply cord, 

at least 4 ft (1.22 m) long, must have three 10-gauge copper wires 

and match a 3-wire receptacle of NEMA Type 10-30R.
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire) 

and be:

Flexible armored cable or nonmetallic sheathed copper cable 

(with ground wire), protected with flexible metallic conduit. All 

current-carrying wires must be insulated.  
10-gauge solid copper wire (do not use aluminum).
At least 5 ft (1.52 m) long.

D

C

34"

(864 mm)

      For a grounded, cord-connected washer/dryer:

This washer/dryer must be grounded. In the event of 

malfunction or breakdown, grounding will reduce the risk of 

electric shock by providing a path of least resistance for 

electric current. This washer/dryer uses a cord having an 

equipment-grounding conductor and a grounding plug. The 

plug must be plugged into an appropriate outlet that is 

properly installed and grounded in accordance with all local 

codes and ordinances.
      For a permanently connected washer/dryer:

This washer/dryer must be connected to a grounded metal, 

permanent wiring system, or an equipment-grounding 

conductor must be run with the circuit conductors and 

connected to the equipment-grounding terminal or lead on 

the washer/dryer.

WARNING:

 Improper connection of the equipment-

grounding conductor can result in a risk of electric shock.

Check with a qualified electrician or service representative or 

personnel if you are in doubt as to whether the washer/dryer 

is properly grounded. Do not modify the plug on the power 

supply cord: if it will not fit the outlet, have a proper outlet 

installed by a qualified electrician.

Содержание LTE5243DQ8

Страница 1: ...iously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on yo...

Страница 2: ...stalling new exhaust vent Level Knife Vent clamps Pliers Scissors Wood block for leveling Ruler or measuring tape If You Have You Will Need to Buy Laundry tub or standpipe taller than 96 2 4 m Sump pump system if not already available 1 25 mm diameter standpipe 2 51 mm diameter to 1 25 mm diameter standpipe adapter Part Number 3363920 Overhead sewer Standard 20 gal 76 L 34 864 mm tall drain tub or...

Страница 3: ...r dryer is recommended to reduce noise transfer For closet installation with a door minimum ventilation openings in the top and bottom of the door are required Louvered doors with equivalent ventilation openings are acceptable Required spacing Rear clearance may be 0 0 mm when house exhaust system is lined up directly with dryer exhaust Mobile Home Additional Installation Requirements This washer ...

Страница 4: ...t grounding through the neutral conductors If using a power supply cord Use a UL listed power supply cord kit marked for use with clothes dryers The kit should contain A UL listed 30 amp power supply cord rated 120 240 volt minimum The cord should be type SRD or SRDT and be at least 4 ft 1 22 m long The wires that connect to the dryer must end in ring terminals or spade terminals with upturned end...

Страница 5: ...d wire green or bare wire must be connected to green ground connector Connect remaining 2 supply wires to remaining 2 terminals gold Securely tighten all electrical connections Failure to do so can result in death fire or electrical shock WARNING Fire Hazard Use 10 gauge solid copper wire Use a UL listed strain relief Disconnect power before making electrical connections Connect neutral wire white...

Страница 6: ...ble Electrical Connection Options If local codes do not permit the connection of a cabinet ground conductor to the neutral wire go to Optional 3 wire connection section 4 wire connection Power supply cord IMPORTANT A 4 wire connection is required for all mobile homes and where local codes do not permit the use of 3 wire connections 1 Remove center silver colored terminal block screw A Removable co...

Страница 7: ...block place the hooked end of the wire under the screw of the terminal block hook facing right squeeze hooked end together and tighten screw See example below 1 Remove center silver colored terminal block screw 2 Remove neutral ground wire from internal ground conductor screw Connect neutral ground wire and place the hooked end hook facing right of the neutral wire white or center wire of direct w...

Страница 8: ...the center silver colored terminal screw of the terminal block Tighten screw 3 Connect the other wires to outer terminal block screws Tighten screws 4 Tighten strain relief screws 5 Insert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw 6 You have completed your electrical connection Now go to Venting Requirements A Neutral wire white or center wire B Ce...

Страница 9: ...own screw 6 You have completed your electrical connection Now go to Venting Requirements Optional 3 wire connection Use for direct wire or power supply cord where local codes do not permit connecting cabinet ground conductor to neutral wire 1 Remove center silver colored terminal block screw 2 Remove neutral ground wire from internal ground conductor screw Connect neutral ground wire and the neutr...

Страница 10: ...ce section of the Washer Dryer User Instructions Rigid metal vent For best drying performance rigid metal vents are recommended Rigid metal vent is recommended to avoid crushing and kinking Flexible metal vent Flexible metal vents are acceptable only if accessible for cleaning Flexible metal vent must be fully extended and supported when the dryer is in its final location Remove excess flexible me...

Страница 11: ...FoamPacking 1 Open the washer lid The latch under the dryer will keep the lid open 2 Pull the foam packing ring out of the washer NOTE Keep the foam ring and use it when transporting your washer dryer This packing material is used to keep the washer tub stable during transport ConnectDrainHose Proper connection of the drain hose protects your floors from damage due to water leakage To keep the dra...

Страница 12: ...by hand until it is seated on the washer 3 Using pliers tighten the couplings with an additional two thirds turn NOTE Do not overtighten or use tape or sealants on the valve Damage to the valves can result Clear the water lines Run water through both faucets and inlet hoses into a laundry tub drainpipe or bucket to get rid of particles in the water lines that might clog the inlet valve screens Che...

Страница 13: ...rap included in the parts package Plastic strap 3 Wrap the drain hose to the laundry tub leg or standpipe with the plastic strap A or B below and secure If the water faucets and the drain standpipe are recessed put the hooked end of the drain hose in the standpipe Tightly wrap the plastic strap around the water inlet hoses and the drain hose C above PlanVentSystem Choose your exhaust installation ...

Страница 14: ...ath outdoors Plan the installation to use the fewest number of elbows and turns When using elbows or making turns allow as much room as possible Bend vent gradually to avoid kinking Use the fewest 90 turns possible Determine vent length and elbows needed for best drying performance Use the Vent system chart below to determine type of vent material and hood combinations acceptable to use NOTE Do no...

Страница 15: ...tic foam for use if the washer dryer should be transported 4 Check the washer dryer s final location Be sure the vent is not crushed or kinked 5 Check that the washer dryer is level and front leveling feet are tight See Level Washer Dryer 6 For power supply cord installations plug into an outlet For direct wire installation turn on power 7 Check that the water faucets are on 8 Check for leaks arou...

Страница 16: ...W10222387A 2008 All rights reserved Benton Harbor Michigan 49022 TM DURASAFE is a trademark of Whirlpool U S A 10 08 Printed in U S A ...

Отзывы: