5
Bearing ass
’
y is defective.
Replace.
Motor wires are
dis-connected.
Capacitor wires are
dis-connected.
Capacitor is defective.
Motor coil shorten.
Brake lining on bearing ass
’
y
is
worn out.
Brake lever ass
’
y is defective.
Torque motor is broken.
Brake lining is
worn out.
Brake lever ass
’
y is defective.
Foreign matter in valve.
Valve spring is deformed.
Valve bellows is deformed.
Torque motor lead wire is
disconnected.
Control circuit board is
defective.
LFP580GR
c.
Wash/Rinse
No
Yes
No
Yes
No
Yes
Yes
No
No
d. Drain
Yes
No
TROUBLE
INSPECTION
CAUSES
REMEDY
Washing cycle does
not start even if
water keeps the
selected water level.
INSPECTION
Does the spin tub
rotated normally
when the
PROCESS button
is set to SPIN?
Bearing ass
’
y is defective.
Poor connect of 6-pin
connectors (blue & white)
Thermostat on motor is
opened.
Control circuit board is
defective.
Replace.
Replace.
Repair or replace
after cooling down.
Replace.
Does the pulsator
rotate by hand?
Does humming
noise come on
from motor?
Replace or repair.
Replace or repair.
Replace.
Replace.
The spin tub rotates
together with the
pulsator during
washing or rinsing
cycle.
Is the torque motor
working normally?
Replace bearing ass
’
y.
Replace bearing ass
’
y.
Replace.
Note:
Break-work
is
normal when spin
tub stops within 10
sec. under no-load.
Does brake-work
normally?
Replace bearing ass
’
y.
Replace bearing ass
’
y.
Water does not
drain out.
Is the torque motor
working normally?
Clean valve inside.
Replace spring.
Replace bellows or
replace valve.
Repair or replace.
Replace.