4-6
REMOVING THE BELT AND THE DRUM
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
1.
Unplug dryer or disconnect power.
2.
Pull the dryer away from the wall so that
you can access the rear of the unit.
3.
Remove the top cover from the dryer (see
page 4-2).
4.
Remove the four screws from the cross-
braces on top of the dryer and remove the
braces.
5.
Disconnect the blue and brown wires from
the AC Line terminal block, then remove
the hex nut from the green ground wires,
and remove the main harness ground wire
from the rear panel (see the top right
photo).
Brown
Blue
AC Line Terminal Block
Air Intake
Cover Screw
Heater & Thermostat
Access Panel
(4 Screws)
6.
Remove the four outer screws from the
heater and thermostat access panel, and
remove the panel assembly from the dryer.
Do not remove the two heater (inside)
screws.
7.
Remove the air intake cover screw and
remove the cover.
Crossbraces
(4 Screws)
8.
Disconnect the heater & thermostat con-
nector from the wire harness.
Heater & Thermostat
Connector
Ground Wires