5-4
BUILT-IN BOARD DIAGNOSTICS
Test User Interface Display
Press and hold "deg. C" and "-" simultane-
ously for 5 seconds to start the test mode.
The user interface will blink all of the 7-seg-
ment displays.
The LEDs will blink
The filter indicator LED will change color, yel
-
low to red to none
Press and hold "deg. C" and "-" simultane-
ously for 5 seconds to exit the test mode.
Defrost Test
Press and hold "Max Cool" and "Holiday"
simultaneously for 3 seconds to start the test
mode.
The defrost heater will be energized immedi-
ately.
A dot will appear at the right end of the tem-
perature display.
Press and hold "Max Cool" and "Holiday"
simultaneously for 3 seconds to exit the test
mode.
Energize evaporator fan motors and ice
maker
Press "Max Cool" and "-" simultaneously for
three seconds to enter the test mode.
The evaporator fans and ice maker circuits
will be energized, by-passing the interior light
switches and temperature control sequence.
Press "Max Cool" and "-" simultaneously for
three seconds to exit the test mode.
Showroom Floor Display Mode
Press and hold "Cooling On/Off" and "Holi-
day Mode" for 3 seconds to enter the display
test mode (this one is the most fun).
The cooling system and ice maker will not
operate but he lights and user interface will
be active.
Press and hold "Cooling On/Off" and "Holi-
day Mode" for 3 seconds to exit the display
test mode