OPERATION
Vesta Gas and Electric Slide-In Ranges
n
2-7
4
AquaLift
®
Self-Cleaning Technology
AquaLift
®
Self-Cleaning Technology is a first-of-its-kind cleaning
solution designed to minimize the time, temperature, and odors
that ordinarily come with traditional self-cleaning methods. With
AquaLift
®
Self-Cleaning Technology, an innovative coating on the
interior of the oven is activated with heat and water to release
baked-on soil. To use AquaLift
®
Self-Cleaning Technology, simply
wipe out loose debris, pour water into the oven bottom, and run the
AquaLift
®
Self-Cleaning cycle. When the cycle finishes in under
1 hour at a lower temperature than traditional self-cleaning
methods, just wipe out the remaining water and loose debris. See
the “Clean Cycle” section for more detailed instructions. For
additional information, frequently asked questions and videos on
using AquaLift
®
Self-Cleaning Technology, visit our website at
http://whr.pl.com/aqualift
Surface Temperatures
When the range is in use, all range surfaces may become hot,
such as the knobs and oven door.
Warming or Storage Drawer
When the oven is in use, the drawer may become hot. Do not store
plastics, cloth, or other items that could melt or burn in the drawer.
Oven Vent
The oven vent releases hot air and moisture from the oven, and
should not be blocked or covered. Do not set plastics, paper or
other items that could melt or burn near the oven vent.
Preheating
When beginning a Bake, Convect Bake or Convect Roast cycle, the
oven will begin preheating after Start is pressed. The oven will take
approximately 12-15 minutes to reach 350°F (177°C) with all of the
oven racks provided with your oven inside the oven cavity. Higher
temperatures will take longer to preheat. The preheat cycle rapidly
increases the oven temperature. The actual oven temperature will
go above your set temperature to offset the heat lost when your
oven door is opened to insert food. This ensures that when you
place your food in the oven, the oven will begin at the proper
temperature. Insert your food when the preheat tone sounds. Do
not open the door during preheat before the tone sounds.
Surface Burners
The burner bases and caps must be properly positioned before
cooking. Your range comes with three sizes of burners and caps.
Align the burner bases as shown in the following illustration:
Align the gas tube opening in the burner base with the orifice
holder on the cooktop and the igniter electrode with the notch in
the burner base.
Place the burner caps on the appropriate burner bases.
Burner caps should be level when properly positioned. If burner
caps are not properly positioned, surface burners will not light. The
burner cap should not rock or wobble when properly aligned.
KEY USAGE TIPS
A. Small
B. Large
C. Medium
D. Medium
E. Large
A. Burner cap
B. Gas tube opening
C. Burner base
D. Igniter electrode
E. Orifice holder
Small cap
Medium cap
Large cap
A. Incorrect
B. Correct
A
D
C
B
E
A
B
C
D
E
A
B
15
Clean Cycle
AquaLift
®
Technology is an innovative cleaning solution that utilizes
heat and water to release baked-on spills from the oven in less
than 1 hour. This new cleaning technology is a low-heat, odor-free
alternative to traditional self-cleaning options.
Allow the oven to cool to room temperature before using the Clean
cycle. If your oven cavity is above 200°F (93°C), “Oven Cooling”
will appear in the display, and the Clean cycle will not be activated
until the oven cavity cools down.
To Clean:
1.
Remove all racks and accessories from the oven cavity and
wipe excess soil. Use a plastic scraper to remove easily-
removed soils.
2.
Pour 1
¾
cups (14 oz [414 mL]) of distilled or filtered water
onto the bottom of the empty oven and close the oven door.
IMPORTANT:
Do not use chemicals or other additives with the
water. Do not open the oven door during the Clean cycle. The
water on the oven bottom is hot.
3.
Press AQUALIFT SELF CLEAN and then START on the oven
control panel.
4.
Allow 40 minutes for cleaning and cool down. A beep will
sound when the Clean cycle is complete.
5.
Press CANCEL at the end of the cycle. Cancel may be
pressed at any time to stop the Clean cycle.
6.
Remove the residual water and loosened soils with a sponge
or cloth immediately after the Clean cycle is complete. Much
of the initial 1
¾
cups (14 oz [414 mL]) of water will remain in
the oven after the cycle is completed. If additional soils
remain, leave a small amount of water in the oven bottom to
assist with the cleaning.
7.
If any soils remain, remove them with a non-scratch scrubbing
sponge or plastic scraper. Additional Clean cycles may be run
to help remove the stubborn soils.
IMPORTANT:
Do not use oven cleaners. The use of
chemicals, including commercial oven cleaners or metal
scouring pads, may cause permanent damage to the porcelain
surface of the oven interior.
NOTES:
■
The range should be level to ensure that the entire surface of
the bottom of the oven cavity is covered by water at the
beginning of the Clean cycle.
■
For best results, use distilled or filtered water. Tap water may
leave mineral deposits on the oven bottom.
■
Before removing the residual water and loosened soils at the
end of the Clean cycle, insert a cloth or paper towel between
the lower edge of the oven door and the front frame to keep
water from spilling onto the front of the range and the floor.
■
Soil baked on through several cooking cycles will be more
difficult to remove with the Clean cycle.
■
Nonabrasive scrub sponges or eraser style cleaning pads
(without cleaners) can be effective for cleaning the oven cavity
walls, oven door and oven bottom for difficult soils. For best
results, moisten the pads and sponges before use.
■
Run an additional Clean cycle for stubborn soils.
■
affresh
®
Kitchen Appliance Cleaner and affresh
®
Cooktop
Cleaner may be used to clean the oven bottom, walls and door
when the oven has finished the cycle and returned to room
temperature. If affresh
®
Cooktop Cleaner is used, it is
recommended to wipe out the cavity with distilled water as
well. Refer to the “Accessories” section for information on
ordering.
■
Additional AquaLift
®
Technology Cleaning Kits may be
obtained by ordering Part Number W10423113RP. See the
“Accessories” section for more information.
■
For assistance with AquaLift
®
Technology, call
1-877-258-0808 in the U.S.A. or 1-800-807-6777 in Canada, or
visit our website at
http://whr.pl/aqualift
.
RANGE CARE
Содержание IEL730C
Страница 18: ...1 14 n Vesta Gas and Electric Slide In Ranges GENERAL INFORMATION NOTES ...
Страница 21: ...OPERATION Vesta Gas and Electric Slide In Ranges n 2 3 Ͷ ǣ Ǧ ǡ Ȁ Ǥ Ͷ ǣ ȌǤ Ǧ Ǥ ȌǤ Ǥ ȌǤ ͳͲ Ǥ ȌǤ Ǥ ǣ ǡ Ͳ Ǥ ...
Страница 32: ...2 14 n Vesta Gas and Electric Slide In Ranges OPERATION NOTES ...
Страница 66: ......